Edan F200 fetal monitor complete casing excluding display screen spare part used
|
|
Edan F200 fetal monitor complete casing excluding display screen spare part
► Brief Description
This complete housing does not include the display screen. It is made of a sturdy and durable special plastic material with a smooth, flat surface that is easy to wipe and clean. It also has a certain degree of corrosion resistance, able to withstand daily disinfection and chemical exposure. It features appropriately sized button holes for easy installation. The interior of the housing has various clips and screw holes for added security, preventing loosening even during transport and impacts. The side of the housing has a row of probes and cable interfaces; users can directly connect the interfaces as needed using the indicated connections.
► Specifications
►Detailed Photos
►Casing Installation Steps
1.Disconnect All Power
Before closing the housing, ensure the motherboard, speakers, battery connection cable, and probe interface board are correctly secured in their corresponding positions on the bottom or front cover.
2.Align the Housing Align the front and back covers. Usually, align the top or bottom of the device first, then gently press around the perimeter to fully engage the clips. A "click" sound usually indicates the clips are locked.
Note: Do not use excessive force. If one side cannot be closed, check if any cables are caught.
3.Tighten the Screws Flip the device over and check the screw holes.
Usually, tighten the screws on the display side first, then tighten the screws on the back. Do not tighten all screws at once; pre-tighten them all, then tighten them one by one at the end to prevent uneven stress on the housing.
4.Inspection Gap Check: Check that the gaps around the housing are even and tight, and that there is no warping.
5.Functional Test: Power on the device and check if the screen display is normal.
Test the button responsiveness.
►Special Precautions
1.The screen and button cables of the F200 are relatively fragile. When closing the cover, ensure the cables are fully embedded in the slots and have sufficient length to avoid breakage.
2.This device typically has some liquid splash resistance. Before installation, please check that the sealing strip is in its original position and not twisted.
3.Screw Length Difference: Screws in different locations may have different lengths. If a long screw is accidentally screwed into a short hole, it may puncture the casing or damage the internal circuit board. It is recommended to manually screw the screw in two turns before installation to feel the resistance. If it cannot be screwed in, stop immediately and check if it is in the wrong hole.
Thank you for your time, if you are interested in our Edan F200 fetal monitor complete casing excluding display screen product, please let me know.
|
||||||||||||||||||||||||||||||
| Product Tags: Edan F200 fetal monitor casing fetal monitor spare part patient monitor replacement casing |
|
Mindray Patient Monitor Battery LI13I001A Suit For Ipm5 Ipm8 Ipm10 Ipm12 IMEC5 IMEC8 IMEC10 IMEC12 New |
|
051-000943-00 Patient Monitor Spo2 Board Mindray T1 IPM12 IPM10 IPM8 Imec8 Imec10 Imec12 |
|
Patient Monitor Printer Recorder TR60-F Mindray IMEC7 IMEC8 IMEC10 IMEC12 IPM8 IPM9 IPM10 IPM12 MEC T5 T6 T8 Series |
|
PHiliph MX400 MX450 MX Series Patient Monitor AC/DC IV2-FLEX ASSY-PWR AC / DC Power Supply 453564281221 |
|
P/N 453564271711 PHiliph MX400 Mx450 MX Series Patient Monitor Mainboard |
|
MX450 Patient Monitor Battery Board Power Supply Hospital Equipment |