Biocare IM12 monitor parameter board assembly includes a SpO2 board PN 02049127
|
|
Biocare IM12 monitor parameter board assembly includes a SpO2 board PN 02049127 This is the parameter module of the Biocare IM12 monitor, featuring a dedicated SpO2 board. The front of the board has multiple interface sockets and chips; the back shows the circuitry, primarily used for signal processing and shielding against battery interference. The parameter board is made of PCB material, offering excellent insulation and anti-interference capabilities. Functional 1. Multi-parameter Integrated Processing: As the core parameter processing module of the Biocare IM12, it is responsible for the acquisition, amplification, filtering, and conversion of key vital signs signals such as SpO2, ECG, NIBP, and Resp, providing rich data references for clinical diagnosis. 2. Integrated SpO2 Board: Includes a dedicated SpO2 board to ensure the accuracy and stability of blood oxygen saturation measurement. 3. Strong Anti-interference: Employing a multi-layer PCB layout and shielding design, it effectively suppresses electromagnetic interference, ensuring that the signal acquisition process is unaffected by electromagnetic interference and guaranteeing accurate and reliable data acquisition. 4. Ease of Maintenance The integrated assembly design simplifies the maintenance process, allowing for simultaneous purchase of all components. Replacing the parameter panel can resolve multiple issues simultaneously, such as abnormal multi-parameter acquisition and SpO2 failure, reducing maintenance costs and downtime. Technical Specifications
Product Images FAQ Q1: What if there is no SpO2 reading or significant fluctuations after replacing the parameter panel? A1: Check if the SpO2 probe and interface connection is loose; clean the probe finger clip contact area with the skin; ensure the parameter panel and mainboard connector are firmly inserted, and recalibrate if necessary. Q2: What if there is severe ECG signal interference or no waveform? A2: Check if the electrode pads are properly attached, and replace the electrode pads; check for damaged leads; test the ECG input circuit of the parameter panel, and replace the entire assembly if necessary. Q3: What precautions should be taken when installing the parameter panel? A3: The following points should be noted: 1. Ensure all connection cables for the parameter panel are properly connected. 2. Pay attention to the tightness of the parameter panel fixing screws during installation; avoid overtightening or loosening, just tighten appropriately. 3. After replacing the parameter board, test it by powering it on first. Only reinstall the casing after everything is normal to avoid repeated disassembly and reassembly if there are any problems. Ordering Information
|
||||||||||||||||||||||
| Product Tags: Biocare IM12 monitor parameter board patient monitor SpO2 board Biocare monitor assembly with warranty |
|
Mindray Patient Monitor Battery LI13I001A Suit For Ipm5 Ipm8 Ipm10 Ipm12 IMEC5 IMEC8 IMEC10 IMEC12 New |
|
051-000943-00 Patient Monitor Spo2 Board Mindray T1 IPM12 IPM10 IPM8 Imec8 Imec10 Imec12 |
|
Patient Monitor Printer Recorder TR60-F Mindray IMEC7 IMEC8 IMEC10 IMEC12 IPM8 IPM9 IPM10 IPM12 MEC T5 T6 T8 Series |
|
PHiliph MX400 MX450 MX Series Patient Monitor AC/DC IV2-FLEX ASSY-PWR AC / DC Power Supply 453564281221 |
|
P/N 453564271711 PHiliph MX400 Mx450 MX Series Patient Monitor Mainboard |
|
MX450 Patient Monitor Battery Board Power Supply Hospital Equipment |