EDAN F2 Fetal Monitor Mainboard 21.53.114321-1 Guaranteed Compatibility Parts
|
|
EDAN F2 Fetal Monitor Mainboard 21.53.114321-1 Guaranteed Compatibility Parts This is the mainboard of the Edan F2 fetal heart rate monitor, part number 21.53.114321-1. The mainboard is made of a PCB board and has multiple white connectors. It integrates chips, a processor, and other small electronic components. As seen in the product details image, the front of the mainboard has multiple interfaces. These interfaces allow key components of the device to connect to the mainboard, and each connector is clearly marked with its corresponding board location to prevent confusion. The back is where signal processing is handled and includes two chips. Functional & Advantages 1. Signal Control and Processing As the "brain" of the EDAN F2, it is responsible for the acquisition, analysis, and processing of signals such as FHR and TOCO. It also receives functional signals from the device, such as screen brightness and mode switching signals, making it the core carrier of all device functions. 2. Communication with Other Modules Through various interfaces, it interacts and controls data with the display screen, keypad, probes, power module, etc., realizing full-function functions such as human-machine interaction, data storage, and alarm management. 3. Data Storage The motherboard has built-in storage capabilities, capable of storing monitored fetal heart rate, uterine contractions, and other data, which can be retrieved and viewed when needed. Technical Specifications
Product Images Installation Steps 1. Power off the device and wait 10 minutes to allow any remaining internal power to dissipate. 2. Remove the outer casing and locate the old motherboard. 3. Disconnect all connections to the motherboard and note the connection position and order of each cable. 4. Unscrew the four corner screws of the motherboard and remove the old motherboard. 5. Align the new motherboard with the positioning posts, tighten the screws, and reconnect all cables and connectors according to the noted positions. 6. Connect the power supply, test the motherboard, and confirm that all functions operate normally before reinstalling the casing. Ordering Information
|
||||||||||||||||||||||||
| Product Tags: EDAN F2 fetal monitor mainboard patient monitor replacement parts compatible fetal monitor mainboard |
|
Mindray Patient Monitor Battery LI13I001A Suit For Ipm5 Ipm8 Ipm10 Ipm12 IMEC5 IMEC8 IMEC10 IMEC12 New |
|
051-000943-00 Patient Monitor Spo2 Board Mindray T1 IPM12 IPM10 IPM8 Imec8 Imec10 Imec12 |
|
Patient Monitor Printer Recorder TR60-F Mindray IMEC7 IMEC8 IMEC10 IMEC12 IPM8 IPM9 IPM10 IPM12 MEC T5 T6 T8 Series |
|
PHiliph MX400 MX450 MX Series Patient Monitor AC/DC IV2-FLEX ASSY-PWR AC / DC Power Supply 453564281221 |
|
P/N 453564271711 PHiliph MX400 Mx450 MX Series Patient Monitor Mainboard |
|
MX450 Patient Monitor Battery Board Power Supply Hospital Equipment |