PHiliph UT3000A monitor parameter panel 35201305000 Medical Equipment Parts
|
|
PHiliph UT3000A monitor parameter panel 35201305000 Medical Equipment Parts The PHiliph UT3000A monitor parameter panel, part number 35201305000, is an original, salvaged parameter panel from the PHiliph UT3000A monitor. It is functional and can be used as a repair or replacement part for the UT3000A monitor. The parameter panel integrates indicator lights and interfaces, providing interfaces for sensors and performing signal conversion. It works in conjunction with the navigation knob and mainboard, forming a core component for human-machine interaction. The parameter panel also features labels with corresponding interface prompts, such as "SpO₂" and "NIBP," allowing medical personnel to easily locate the correct interface and save operation time. Key Features 1. Signal Conversion Provides an interface for the sensor, enabling signal conversion and transmission to other components for analysis. 2. Labeling and Warnings The panel is labeled with the corresponding function of each interface (e.g., "SpO₂", "NIBP") and safety warnings to facilitate correct connection by clinical personnel. 3. Strong Compatibility As seen in the product details image, the interface board has reserved holes for SpO₂ and NIBP interfaces, ensuring compatibility with the high-end UT3000A monitor. 4. Enhanced Aesthetics The overall color scheme corresponds to the main body of the monitor, creating a harmonious look and enhancing the overall aesthetics of the device. Technical Specifications
Product Images FAQ Q1: The monitor displays no sensor signal. Is this an interface board malfunction? A1: Connect the sensor to another device to check for sensor malfunction. If the sensor is normal, check if the communication between the parameter panel and the main unit is interrupted, and check the wiring connections. If communication is normal, replace the parameter panel. Q2: The monitor keeps interrupting data acquisition due to a loose interface. How can this be resolved? A2: Check if the interface pins are damaged, such as deformed or bent pins. Replace the interface board promptly to avoid affecting monitoring efficiency. Q3: Can I replace the interface board myself? A3: The interface board is secured with clips and screws, making replacement relatively simple. You can replace it yourself, but be careful not to connect sensors during replacement to avoid damaging them. Ordering Information
|
||||||||||||||||||||||
| Product Tags: Signal Conversion Parameter Panel Labeling and Warnings Interface Board Strong Compatibility Medical Monitor Parts |
|
Mindray Patient Monitor Battery LI13I001A Suit For Ipm5 Ipm8 Ipm10 Ipm12 IMEC5 IMEC8 IMEC10 IMEC12 New |
|
051-000943-00 Patient Monitor Spo2 Board Mindray T1 IPM12 IPM10 IPM8 Imec8 Imec10 Imec12 |
|
Patient Monitor Printer Recorder TR60-F Mindray IMEC7 IMEC8 IMEC10 IMEC12 IPM8 IPM9 IPM10 IPM12 MEC T5 T6 T8 Series |
|
PHiliph MX400 MX450 MX Series Patient Monitor AC/DC IV2-FLEX ASSY-PWR AC / DC Power Supply 453564281221 |
|
P/N 453564271711 PHiliph MX400 Mx450 MX Series Patient Monitor Mainboard |
|
MX450 Patient Monitor Battery Board Power Supply Hospital Equipment |