Plilipph UT3000A monitor battery compartment spring component for Hospital ICU Clinic
|
|
Plilipph UT3000A monitor battery compartment spring component
►Brief Description
The battery compartment spring assembly is suitable for the UT3000A monitor. The most critical function of the battery compartment spring is that it serves as the primary electrical contact point between the power supply and the monitor's circuitry. This spring is made of stainless steel copper, offering strong corrosion and oxidation resistance, ensuring stable conductivity even after long-term use. The spring surface is coated to enhance conductivity and prevent galvanic corrosion. The spring compresses when the battery is inserted and then expands upon further insertion, maintaining constant pressure on the battery terminals.
►Specification
►Product photos
►Battery Spring component Functions
1. Conductivity: The spring must provide a low-resistance path for current to flow from the battery to the device.
2. Mechanical Retention: The spring must provide continuous pressure to securely hold the battery in place and prevent disengagement due to vibration or movement.
3.Good electrical conductivity:The spring can withstand thousands of compression cycles (battery insertion and removal) without losing its "rebound" force, and the spring fits perfectly into the battery compartment, so even if the monitor is moved, the spring's conductivity will not be affected.
If the battery spring fails, the monitor may experience intermittent power outages, screen flicker, or complete shutdown, rendering the device unusable during travel or emergency situations.
►Caution:
1. Leaving a battery in a device for an extended period of time can cause leaking fluid to corrode the spring surface, increasing resistance. 2. Over time, metal fatigue can cause the spring to sag and lose contact with the battery. Solution: If your monitor won't power on, first check the spring for debris or corrosion. Gently wiping the spring contacts with a cotton swab dipped in isopropyl alcohol will usually restore functionality. If the spring is physically damaged or flattened, it will need to be professionally replaced to restore the precise tension required for reliable operation.
Thank you so much for your attention .If you're interested in Plilipph UT3000A monitor battery compartment spring component. feel free to contact us ,we will reply to you within 24 hours.
|
||||||||||||||||||||||||||
| Product Tags: patient monitor battery spring ICU monitor battery component hospital monitor replacement part |
|
Mindray Patient Monitor Battery LI13I001A Suit For Ipm5 Ipm8 Ipm10 Ipm12 IMEC5 IMEC8 IMEC10 IMEC12 New |
|
051-000943-00 Patient Monitor Spo2 Board Mindray T1 IPM12 IPM10 IPM8 Imec8 Imec10 Imec12 |
|
Patient Monitor Printer Recorder TR60-F Mindray IMEC7 IMEC8 IMEC10 IMEC12 IPM8 IPM9 IPM10 IPM12 MEC T5 T6 T8 Series |
|
PHiliph MX400 MX450 MX Series Patient Monitor AC/DC IV2-FLEX ASSY-PWR AC / DC Power Supply 453564281221 |
|
P/N 453564271711 PHiliph MX400 Mx450 MX Series Patient Monitor Mainboard |
|
MX450 Patient Monitor Battery Board Power Supply Hospital Equipment |
