China Used Patient Monitor manufacturer
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group Win-win together!
6
Home > Products > Patient Monitor Parts >

Mindray IPM-9800 SPO2 Plate 050-00046-00 110mm×90mm×1.6mm

Browse Categories

China World Technology Medical Equipment Service Group

City: guangzhou

Province/State:guangdong

Country/Region:china

Tel:86-198-5481-5217

Contact Person:
Miss.Kiara
View Contact Details

Mindray IPM-9800 SPO2 Plate 050-00046-00 110mm×90mm×1.6mm

Brand Name Mindray
Model Number IPM-9800
Minimum Order Quantity 1 Piece
Price USD
Payment Terms T/T,Western Union,Paypal
Delivery Time 3-5 working days
Packaging Details Carton
Product Name SPO2 Plate
Model F07652
Rated voltage 050-00046-00 051-000058-00
Condition Used-good
Size 110mm×90mm×1.6mm
Weight About 60g
MOQ 1 Piece
Payment terms Bank TT/ Paypal/Western Union
Deposit 100% pay before shipping
Shipping time Different
Detailed Product Description
Mindray IPM-9800 Monitor SPO2 Plate 050-00046-00 051-000058-00

Mindray IPM-9800 Monitor SPO2 Plate includes two models: 050-00046-00 and 051-000058-00. The 050-00046-00 focuses on signal processing, while the 051-000058-00 focuses on interface drivers. Together, they form a complete blood oxygen monitoring unit, the core hardware for accurate SpO₂ and PR measurements. Their materials and circuit design fully meet the stringent requirements of medical equipment for stability, interference immunity, and safety.

Product Specifications
Product nameSPO2 Plate
ModelMindray IPM-9800
PN050-00046-00 051-000058-00
Circuit board materialmedical grade FR-4 epoxy glass cloth laminate
Shipping timeDifferent
Deposit100% pay before shipping
Payment termsBank TT/ Paypal/Western Union
MOQ1 Piece
Size110mm*90mm*1.6mm
WeightAbout 60g
Core Functions
  1. Signal Acquisition and Preprocessing
  2. Blood Oxygen Saturation Calculation
  3. Probe Adaptation and Driver
  4. Probe Status Diagnosis
Frequently Asked Questions
Q1: The device displays "SpO₂ signal weak." I've checked the probe and it's fine. Is the oximeter board faulty?
A1: Turn off the power and check if the power cord is securely plugged in. After powering on the device, enter maintenance mode and check the oximeter board self-test results. If it displays "Signal amplification circuit abnormality" (fault code E04), the oximeter board is faulty and should be replaced.
Q2: Can the two oximeter boards be replaced separately? Or must they be replaced together?
A2: They can be replaced separately, depending on the fault type: ① If "Probe cannot be recognized" or "Drive current abnormality" occurs, it's likely that the 051-000058-00 board is faulty and can be replaced alone. ② If "Oximeter calculation error is large" or "Weak signal cannot be calibrated" occurs, it's likely that the signal processing chip or filter circuit on the 050-00046-00 board is faulty and should be replaced alone. ③ After replacement, power on the device and perform "SpO₂ calibration" to ensure measurement accuracy meets requirements.
Q3: The blood oximeter board gets noticeably hot while operating (approximately 65°C to the touch). Is this normal?
A3: It's not normal. The normal operating temperature should be ≤60°C. Possible causes of abnormal heating: ① The heat sink may have fallen off or the thermal grease may have dried out. Disassemble the device to inspect the heat sink on the 050-00046-00 board and reapply thermal grease (0.5mm thick). ② The driver chip is overcurrenting. Measure the probe LED current to see if it exceeds 80mA.
Product Images
Ordering Information
Payment MethodsBank Transfer / PayPal / Western Union