China Used Patient Monitor manufacturer
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group Win-win together!
6
Home > Products > Patient Monitor Parts >

Welch Spot Vital Signs Lxi Display MG96-L38SG 41021201F102

Browse Categories

China World Technology Medical Equipment Service Group

City: guangzhou

Province/State:guangdong

Country/Region:china

Tel:86-198-5481-5217

Contact Person:
Miss.Kiara
View Contact Details

Welch Spot Vital Signs Lxi Display MG96-L38SG 41021201F102

Brand Name Welch
Model Number spot vital signs Lxi
Minimum Order Quantity 1 Piece
Price USD
Payment Terms T/T,Western Union,Paypal
Delivery Time 3-5 working days
Packaging Details Carton
Product Name Display
PN MG96-L38SG 41021201F102
Application Machine Welch
Display type 3.5-inch TFT LCD
Connection method 20pin flexible cable
Display resolution 320×240 pixels
Contrast ratio 400:1
Size 90mm×60mm×5mm
Weight About 450g
Condition Used-good
Detailed Product Description
Welch spot vital signs Lxi display MG96-L38SG 41021201F102 With Clear High-contrast Visuals Display
Product Specifications
Products NameDisplay
ModelMG96-L38SG 41021201F102
Applicable devicesSpot Vital Signs Lxi Spot Vital Signs Lxi (Enhanced Edition)
Display type3.5-inch TFT LCD
Connection method20pin flexible cable
Display resolution320*240 pixels
Contrast ratio400:1
Viewing anglehorizontal 160°/ vertical 140°
Display color262K colors
Interface plug-in life≥5000 hours
Size90mm*60mm*5mm
WeightAbout 450g
Core Functions
1.

Data Display: The display displays various data and waveforms in real time, enabling healthcare providers to quickly access critical blood pressure information. The SpO₂ value is dynamically displayed, updating every 5 seconds, making it easy to observe fluctuations in the patient's blood oxygen status.

2.

Status Indicator: Equipped with multiple status indicators, each with its own function, the screen also displays corresponding error codes and brief descriptions, helping medical staff quickly identify problems.

3.

Operation Feedback: When medical staff operate the device buttons, the display immediately responds, providing clear feedback and enhancing the smoothness of human-computer interaction.

4.

Historical Data Display: The display displays 50 sets of historical measurement records stored in the device, arranged in chronological order. Each record contains complete vital sign data and measurement timestamps.

Technical Details

Welch Allyn Spot Vital Signs Lxi features the MG96-L38SG 41021201F102 display, a key interface for device information presentation and healthcare provider interaction. This 3.5-inch TFT LCD features high contrast and a wide viewing angle, ensuring clear reading of vital sign data such as NIBP, SpO₂, and temperature in all lighting conditions and from all angles.

The display measures approximately 90mm * 60mm * 5mm and weighs approximately 50g. Once installed, the screen fits snugly to the frame, with a margin gap of ≤0.2mm, ensuring the device's overall seal and aesthetics. The screen is covered with a high-strength, highly transparent acrylic protective panel, effectively resisting daily scratches. With a transmittance of up to 92%, the display protects the internal LCD without compromising clarity.

Frequently Asked Questions
Q1: What should I do if the display is distorted or displays abnormally?

A1: There are multiple possible causes, and each one needs to be investigated to confirm the problem: First, check if the cable connecting the display to the motherboard is loose. Reconnect and reconnect to ensure a secure connection. If the connection is normal, the display circuit may be faulty or the screen may be damaged. Turn off the device, wait 5-10 minutes, then restart it to see if it returns to normal. If the problem persists, contact a professional to replace or repair the display or driver circuit board.

Q2: The measurement data displayed on the screen is inaccurate and deviates significantly from the actual situation. Is the display a problem?

A2: Not necessarily. Inaccurate measurement data may be caused by a fault in the device's measurement module (such as the NIBP sensor, SpO₂ probe, or temperature sensor), a calibration error, or patient-related factors. Contact a professional to investigate the issue and then decide whether to repair or replace the display.

Q3: The display brightness suddenly decreased. How can I adjust it?

A3: Some Spot Vital Signs Lxi devices support screen brightness adjustment. Find "Display Settings" or "Brightness Adjustment" in your device's settings menu and increase the screen brightness using the buttons or touch (if touch is supported). If there's no brightness adjustment feature, the screen automatically adjusts based on the current environment. Move your device to a brighter location.

Product Images
Ordering Information
Payment MethodsBank Transfer / PayPal / Western Union
Delivery MethodsDHL / FedEx
Product Tags: Welch Spot Vital Signs monitor display   MG96-L38SG patient monitor part   41021201F102 vital signs display  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: China World Technology Medical Equipment Service Group
Subject:
Message:
Characters Remaining: (80/3000)