PHiliph VM6 Patient Monitor Parts Nibp Pump 453564015271 453564052551 453664015831
|
|
PHiliphh VM6 patient monitor Nibp Pump 453564015271 453564052551 453664015831
SureSign's VM Series monitors systolic, diastolic and mean arterial pressure (MAP) by recording pressure pulses through a series of controlled contraction steps in an inflated cuff.
There are three types of NBP measurements: Manual measurement - Press the NBP button on the front panel to start an NBP measurement. • Interval Measurements – Starts NBP measurements every n minutes, where n is the number of minutes between measurements. Please change the specified time interval in the Blood Pressure menu. • STAT measurements - The monitor takes as many measurements as possible in 5 minutes, with pauses between each measurement.
Limitations of NBP measurement You cannot measure NBP in a patient with a heart rate of less than 40 or more than 300 or on a heart-lung machine. NBP measurement may be inaccurate or impossible in patients with the following conditions: 1. Irregular arterial pressure pulsation 2. Arrhythmia 3. Excessive and repetitive movements, such as shaking or twitching 4. Blood pressure changes rapidly 5. Severe shock or hypothermia, which reduces blood flow to the area 6. Obesity, a thick layer of fat around a leg, weakens the vibrations in the arteries 7. Edema limbs
The Suresigns Monitor can contain PHiliphh NBP or CAS NBP hardware modules. The steps to measure NBP are the same whether the monitor contains a PHiliphh NBP module or a CAS NBP module. However, since the monitors in your care setting may contain different NBP modules, you should be aware of these differences:
Conditions causing NBP technical alerts NBP measurement limits trigger physiological alarms when exceeded Define NBD Initial set of NBP inflation pressure setting
You can determine whether your monitor contains a PHiliphh NBP module or a CAS NBP module by looking at the configuration settings in the system menu. If your display contains a PHiliphh NBP module, the configuration settings contain the text NBP-P; If the display contains the NBP-CAS module, the configuration settings contain the text NBP-C.
If you're interested in PHiliphh VM6 Patient Monitor Nibp Pump 453564015271 453564052551 453664015831,feel free to contact us .Thank you .
|
||||||||||||
| Product Tags: PHiliph VM6 Patient Monitor Parts 453564015271 Patient Monitor Parts 453664015831 Nibp Pump |
|
Mindray Patient Monitor Battery LI13I001A Suit For Ipm5 Ipm8 Ipm10 Ipm12 IMEC5 IMEC8 IMEC10 IMEC12 New |
|
051-000943-00 Patient Monitor Spo2 Board Mindray T1 IPM12 IPM10 IPM8 Imec8 Imec10 Imec12 |
|
Patient Monitor Printer Recorder TR60-F Mindray IMEC7 IMEC8 IMEC10 IMEC12 IPM8 IPM9 IPM10 IPM12 MEC T5 T6 T8 Series |
|
PHiliph MX400 MX450 MX Series Patient Monitor AC/DC IV2-FLEX ASSY-PWR AC / DC Power Supply 453564281221 |
|
P/N 453564271711 PHiliph MX400 Mx450 MX Series Patient Monitor Mainboard |
|
MX450 Patient Monitor Battery Board Power Supply Hospital Equipment |