Patient Bedside Monitor ECG Board Mindray MEC2000 PM7000 PM8000 PM9000
|
|
Mindray MEC2000 PM7000 PM8000 PM9000 patient monitor ECG board
►Brief Introduction This module is designed to measure three parameters including ECG, RESP and TEMP.
► Specifications
► Functions This module uses ECG cables and TEMP sensors to collect ECG, RESP and TEMP signals, process them and transmit them to the main board through serial port. ECG Signal Input Circuit Input protection and filter circuit: receives ECG signals from ECG cables, removes high-frequency interference and prevents the circuit from being damaged by high voltage generated in defibrillation and ESD. Right leg drive circuit: picks up 50/60Hz common-mode signals in lead wire and feeds them back to patient body; suppresses the common-mode interference in lead wire for the sake of better detecting ECG signals. Lead Off detection circuit: detects if any ECG lead falls off and transmits relevant message to CPU. ECG Signal Process Circuit Differential Amplification circuit: first-order amplifies ECG signals and suppresses common-mode interference at the same time. Low-pass filter circuit: removes high-frequency interference outside frequency band of ECG signals. PACE signals are ECG pacing signals, which greatly affect ECG detecting performance. Therefore PACE suppression circuit is designed to suppress PACE signals in order to better detect ECG signals. Master AMP/Filter circuit: amplifies and filters ECG signals again and transmits them furthermore into A/D converter. Pace Detect Pick PACE signals out of ECG signals and transmit them to CPU. Temperature Detect Circuit Receive signals coming from TEMP sensor, amplify and filter the signals and transmit them furthermore into A/D converter. Carrier Generate Circuit RESP measurement is based on Impedance method. Respiration causes the changes of thoracic impedances, which feature is taken advantage to modulate the amplitude of high frequency carrier. The modulated signals are then sent into the measuring circuit. This circuit is designed to generate high frequency carrier RESP Signal Input Circuit Couples the RESP signals into the detection circuit. RESP Signal Process Circuit Preamplifier circuit: amplifies and filters RESP signals; Detection circuit: picks out the RESP wave modulated in excitation signals; Level translation circuit: removes DC components in RESP signals; Master AMP/Filter circuit: amplifies and filters RESP signals again and transmits them furthermore into A/D converter. A/D Convert analog signals output from each parameter circuit into digital signals, and send them into CPU part to receive further processing. CPU System Realize logic control over all parameter parts and A/D part. Process data of each parameter; Communicate with main board. Power & Signal Isolate Circuit Realize isolation from external circuit in order to ensure human safety; Provide power supplies for circuits; Realize isolating communication between CPU System and main board.
► About Us
etc.
If you want to explore more details about Mindray MEC2000 PM7000 PM8000 PM9000 Patient Bedside Monitor ECG board, please let us know. Looking forward to receiving your early inquiry.
|
||||||||
| Product Tags: Patient Bedside Monitor ECG Board PM7000 Monitor ECG Board PM9000 Monitor ECG Board |
|
Mindray Patient Monitor Battery LI13I001A Suit For Ipm5 Ipm8 Ipm10 Ipm12 IMEC5 IMEC8 IMEC10 IMEC12 New |
|
051-000943-00 Patient Monitor Spo2 Board Mindray T1 IPM12 IPM10 IPM8 Imec8 Imec10 Imec12 |
|
Patient Monitor Printer Recorder TR60-F Mindray IMEC7 IMEC8 IMEC10 IMEC12 IPM8 IPM9 IPM10 IPM12 MEC T5 T6 T8 Series |
|
PHiliph MX400 MX450 MX Series Patient Monitor AC/DC IV2-FLEX ASSY-PWR AC / DC Power Supply 453564281221 |
|
P/N 453564271711 PHiliph MX400 Mx450 MX Series Patient Monitor Mainboard |
|
MX450 Patient Monitor Battery Board Power Supply Hospital Equipment |