REF 200101 Masima IRMA Co2 Sensor For Hospital 90ms Rise Time
|
|
Masima 200101 IRMA Co2 Sensor New Condition For Hospital
Versatile, traditional capnography and multi-gas technology in a compact, lightweight design > Designed to accurately and continuously measure inhaled and exhaled gas concentration and respiratory rate in real time • Ability to measure CO2, N2O and anesthetics (HAL, ENF, ISO, SEV, DES) with automatic proxy ID > Thanks to its unique and flexible design, IRMA is the only conventional multi-gas analyzer in the world.
Features and Benefits: > Compact size and lightweight design enable monitoring of adult, pediatric, and neonatal patients in a variety of clinical settings, including operating rooms, intensive care units, emergency rooms, and during transport > Fully accurate performance in seconds with virtually no warm-up time, allowing clinicians to quickly obtain accurate data for effective response > Flexible design supports monitoring of patients with high respiratory rates (up to 150 bpm) while providing clear waveforms with fast rise times > Low power consumption and automatic temperature and pressure compensation make IRMA gas analyzers easy to maintain > Small footprint and multiple configurations available for easy integration > Acquires measurements through the air tube through the IRMA airway adapter without removing breathing gas from the patient
Specification
The IRMA™ head probe assembly is as small as an oximeter sensor, weighing only 25 grams. It has been engineered using the latest components and microprocessor technology to provide a complete conventional monitoring system with unique design and versatility. The IRMA™ probe measures the absorption of infrared light at ten different wavelengths to accurately determine gas concentrations in mixtures. A range of disposable airway adapters are available for all clinical applications. IRMA™ probes contain all the components required for advanced signal processing and a fully digital RS232 interface. All probes are universally calibrated and provide processed data for display on the monitor, ventilator or anesthesia machine screen. This allows complete system integration flexibility without hardware modification of the host device.
If you're interested in REF 200101 Masima IRMA Co2 Sensor New Condition For Hospital ,feel free to contact us .Thank you . |
||||||||||||||||||||
| Product Tags: 90ms Rise Time Co2 Sensor Hospital Co2 Sensor REF 200101 Masima IRMA Co2 Sensor |
|
Mindray Patient Monitor Battery LI13I001A Suit For Ipm5 Ipm8 Ipm10 Ipm12 IMEC5 IMEC8 IMEC10 IMEC12 New |
|
051-000943-00 Patient Monitor Spo2 Board Mindray T1 IPM12 IPM10 IPM8 Imec8 Imec10 Imec12 |
|
Patient Monitor Printer Recorder TR60-F Mindray IMEC7 IMEC8 IMEC10 IMEC12 IPM8 IPM9 IPM10 IPM12 MEC T5 T6 T8 Series |
|
PHiliph MX400 MX450 MX Series Patient Monitor AC/DC IV2-FLEX ASSY-PWR AC / DC Power Supply 453564281221 |
|
P/N 453564271711 PHiliph MX400 Mx450 MX Series Patient Monitor Mainboard |
|
MX450 Patient Monitor Battery Board Power Supply Hospital Equipment |