China Used Patient Monitor manufacturer
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group Win-win together!
6
Home > Products > Patient Monitor Parts >

PHiliph Avalon FM20 FM30 Fetal Monitor Power Supply M2703-60001 451261007261

Browse Categories

China World Technology Medical Equipment Service Group

City: guangzhou

Province/State:guangdong

Country/Region:china

Tel:86-198-5481-5217

Contact Person:
Miss.Kiara
View Contact Details

PHiliph Avalon FM20 FM30 Fetal Monitor Power Supply M2703-60001 451261007261

Brand Name PHiliph
Model Number FM20 FM30
Minimum Order Quantity 1
Payment Terms T/T, Western Union,PayPal
Delivery Time 3-5 working days
Product name PHiliph FM20 fetal monitor
Type FM20 FM30
Application medical equipment,ICU,hospital
Warranty 90days
Functions Monitor Patient's health condition,Print electrocardiogram
Usages ICU, emergency, Patient Monitor, ICU Room and operating room
Preponderances Specialized engineers with 12 years of experience
After-sale Service If we find non-human damage, we will be free for you to repair or returned
Supported languages English,French,Italian,Spanish,Japanese,Hindi,Portuguese,Russian,etc
Management Principles Advanced technology, high-quality products, attentive service
Condition In Good Order
Nominal Voltage 110V—240v
Product feature Durable in use,Functional
MEANS OF TRANSPORT Expressage
Supply Frequency Range 50 Hz/60 Hz
Power Consumption 0.7 - 0.4 A / 1.3 - 0.7 A
Detailed Product Description

Hospital Medical Equipment Parts PHiliphh Avalon FM20 FM30 Fetal Monitor Power Supply Used M2703-60001 451261007261

 

 

 

Brief Introduction

Disconnecting from Power

To disconnect the monitor from AC power, switch the monitor off using the On/Off switch located on the right side of the device, or unplug the power cord from the AC mains socket.

The On/Standby button does not disconnect the monitor from the AC power source. To disconnect, unplug the power cord from the AC mains socket. Note that if the power cord is unplugged from the AC mains socket before the monitor is put into Standby, a beeper is activated. The beeper warns you if the monitor is accidentally disconnected from AC mains.

 

Power On/Power Off Behavior

The general rules determining the behavior of the fetal monitors when connected to, or disconnected from power are as follows:

  • A fetal monitor that was switched on prior to a temporary power loss, switches on again when power is restored.
  • A fetal monitor that was switched off prior to a temporary power loss, remains off when power is restored.
  • When AC mains power is lost, a battery powered monitor (FM20/30) continues to run without interruption on battery power.

 

 

Removing and Replacing the Power Supply Assembly

1 Remove the top cover assembly .

2 Disconnect the power supply cable connector from the main CPU board. While removing the connector, support the end of the main CPU board to prevent excessive flexing.

3 Remove the three screws securing the power supply.

4 Lift the cable end of the power supply assembly with one hand, while guiding the power socket/on/off switch free of the aperture in the bottom housing, then lift out the power supply.

The procedure to replace the power supply assembly is a reversal of the removal procedure. Remember to reconnect the power supply cable connector.

 

 

► Power Supply Assembly Contents

Power Supply Angle1
Power Supply Frame1
Nut, press in M33
Insulation1
Screw with washer, M3 x 63

 

 

► Specifications

Supply Voltages100 VAC to 240 VAC ±10%
Supply Frequency Range50 Hz/60 Hz
Power Consumption0.7 - 0.4 A / 1.3 - 0.7 A

 

 

► About Company

We mainly sell different kinds of medical equipments, accessories and repair parts including patient monitor, defibrillator machine, patient monitor printer, ECG machine, EKG machine, main board, batteries and so on. After many years of marketing and developing, we are quiet proficient in medical machines technology. Our products are increasingly popular and enjoy good reputation at home and abroad. Relying on superior products quality and reasonable price, our sales have been growing steadily with each passing year. We are a reliable manufacturer providing the best products and services for global customers. Satisfying all the customers' demands is our permanent pursuit.

 

 

We seek for providing perfect service to the satisfaction of customers. 

Thank you for your time! If you are interested in PHiliphh Avalon FM20 FM30 Fetal Monitor Power Supply Used M2703-60001 451261007261, welcome to place your orders. Early order early shipment!

► 

Product Tags: FM30 Fetal Monitor Power Supply   M2703-60001 Fetal Monitor Power Supply   451261007261 Fetal Monitor Power Supply  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: China World Technology Medical Equipment Service Group
Subject:
Message:
Characters Remaining: (80/3000)