Cardiosave Maquet Battery 0146-00-0097 Medical Hospital Device Parts
|
|
Medical Device Hospital Equipment Parts Cardiosave MAQUET Battery 0146-00-0097
►Brief Introduction Prior to using the CARDIOSAVE IABP, insure the two (2) Li-Ion Batteries are fully charged and properly installed into the IABP console. Each fully charged battery can provide, at minimum, one (1) hour of IABP operating time @ 120 BPM. Do not take spare batteries during transport. In these transport applications, an inverter and Transport AC Power Supply are required to ensure continued AC Power once the batteries are depleted. If an inverter and Transport AC Power Supply are not available, do not use the IABP for transport applications. Please Note: The two (2) CARDIOSAVE Li-Ion Batteries once properly installed into the IABP are not affected by the risk of damage due to a drop. CARDIOSAVE Li-Ion Batteries are to be replaced every four (4) years or when the run time is less than 60 minutes per battery @ 120 BPM.
► Battery Location and In-Use Indicators Battery Overview It is extremely important to know the location of the batteries on the back panel of the Cardiosave unit and to pay attention to the “in-use” indicators.
Battery Bay In-Use Indicators There are two Battery Bay indicators, one over each Battery Bay, which indicate which bay is currently in use by the IABP. The indicator will illuminate green if the IABP is charging a battery or operating from power supplied by the corresponding Battery Bay.
Battery Bays The Battery Bays provide the IABP with the ability to operate from a portable power source. They have a common PHiliphhilipysical lock which prevents simultaneous removal of both power sources.
► Installation and Removal of Batteries The IABP is capable of running from DC battery power supplied by lithium-ion rechargeable batteries which can be installed in the two(2) Battery Bays on the Pump Console. To avoid interruption of therapy, discharged batteries should be replaced with new charged batteries as necessary. 1. Turn knob to remove battery from Battery Bay. 2. Slide battery OUT. 3. Slide charged battery IN. 4. While holding battery in bay, turn knob to lock battery in place
WARNING:
► Viewing Battery Status on Battery Monitoring
Looking forward to receiving your early inquiry about Cardiosave MAQUET Battery 0146-00-0097 . Thank you for your time!
|
||||||||||||||
| Product Tags: Cardiosave Maquet Battery 0146-00-0097 Maquet Battery |
|
Mindray Patient Monitor Battery LI13I001A Suit For Ipm5 Ipm8 Ipm10 Ipm12 IMEC5 IMEC8 IMEC10 IMEC12 New |
|
051-000943-00 Patient Monitor Spo2 Board Mindray T1 IPM12 IPM10 IPM8 Imec8 Imec10 Imec12 |
|
Patient Monitor Printer Recorder TR60-F Mindray IMEC7 IMEC8 IMEC10 IMEC12 IPM8 IPM9 IPM10 IPM12 MEC T5 T6 T8 Series |
|
PHiliph MX400 MX450 MX Series Patient Monitor AC/DC IV2-FLEX ASSY-PWR AC / DC Power Supply 453564281221 |
|
P/N 453564271711 PHiliph MX400 Mx450 MX Series Patient Monitor Mainboard |
|
MX450 Patient Monitor Battery Board Power Supply Hospital Equipment |