Titanium Clad Copper Wire Introduction
We are titanium cladded copper wires manufacturers in China
since 2001.
titanium clad copper wire diameter can be 2~6.35mm, the titanium
thickness can be custom as your need, unit coil length can be
100meters long.
The big advantage of titanium copper composite wire is corrosion
resistance and good conductivity. combine the titanium and copper
material advantages. now it is widely used in cathodic protection
field, make it as the base material, its resistance is much lower
than pure gr1 titanium.
Titanium Clad Copper |
Substrate | Copper T1 T2 |
Cladding Materials | Titanium |
Standard | GB/T12769-2003 ASTM B432 |
Diameter
| Wire: 2 - 6.35mm (Other materials and specifications can be produced according to
customer requirements.) |
titanium thickness | can be custom as your need |
unit coil length | can be 100meters long |
Product Plan Display:
Our ISO 9001:2015 certificate
The process of the titanium clad copper wire is explosion and hot rolled, details please check follows:
The explosion method firstly puts the copper rod into the titanium
tube, uniformly distributes the explosive material outside the
titanium tube, and uses the detonator to detonate the explosive, so
that the copper rod and the titanium tube form a composite under
the action of the explosive force. Since the cross-sectional size
of the titanium-copper composite rod is generally small, the
production yield by the explosion method is low, resulting in high
cost, and no one in the industrial production currently adopts this
method.
Explosion + rolling method is to use a larger size of titanium tube
and copper rod, the blank is made by the explosion method, and then
the finished composite rod is produced by the method of hole
rolling. Compared with the direct explosion method, this method has
the advantages of improving efficiency and reducing cost. The
composite rods produced by the composite strength and other
indicators are also good. However, since the rolling processing
amount should not be too large, that is, the elongation coefficient
is not large, it is not suitable for mass production. and for a
rectangular composite rod, the corners are not easily filled. If
the amount of deformation of the pass is not well controlled, there
may be a crimp or ear. Due to the use of the finished hot rolling
method, the composite rod has poor bending resistance and has an
impact on the use.
Tag: titanium cladded copper wires suppliers,titanium clad copper wire,titanium cladded copper wires