15G 12-Channel Full Rate Optical Error Meter 622M~15.0G BERT

Brand Name YOUCii
Model Number U9210F
Place of Origin CHINA
Minimum Order Quantity 1
Price Negotiate price
Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability 10pcs / month
Delivery Time 20 work days
Packaging Details Paper Box
Connection Port Optical port
Number Of Channels 12
Type error code tester
Storage Temperature -20~+70 ℃
Interface USB, LAN, GPIB
Case Temperature 5~45°C
Model U9210F
Detailed Product Description

15G 12-Channel Full Rate Optical Error Meter 622M~15.0G BERT



Feature overview
High speed: Data rates up to 15Gbps are supported to meet the test requirements of modern high-speed optical communication systems.


Multi-channel: With 12 optical port channels, all channels can synchronize input and output, can parallel error detection, improve test efficiency.


Full rate test: Support from low speed to high speed full rate error test, covering multiple conventional rate points, suitable for the current conventional active module.


High precision: With low jitter clock output and high-precision error detection capabilities to ensure the accuracy of test results.



12 electrical channels (note that this is an example of an electrical port, and the features of an optical port are similar) : All channels synchronize input and output to enable independent error detection.


Continuous and periodic bit error detection: Provides comprehensive bit error detection.


Support a variety of code types: such as PRBS7, PRBS23, PRBS31, etc., to meet different test needs.


Low jitter clock output: Ensure the stability of the test signal.


Specification

No.ArgumentMinModelMaxunit
1Data rate0.6140.614,1.22,2.25,2.457,2.5,3.07,3.125,4.915,5.0,6.144,6.25,8.5,9.953,10.00,10.3125,10.52,10.709,11.09,11.32,11.519,11.711.7Gbps
2Number of channels
12 (12 channel port)

3Code pattern
PRBS7,PRBS9,PRBS15,PRBS23,PRBS31

4Rise and fall time (20% to 80%)
1823ps
5Pattern reversal
Supports signal inversion at the transmitting and receiving ends

6Signal output amplitude (single-ended)2008001000mV
7Data output jitter (RMS)
1.5(10.3125G)
ps
8Data input/output interface
Differential, AC coupling, 50 ohm impedance, SMA

9Clock output100156.25156.25MHz
10Data signal input sensitivity (single-ended)
0.1
Vpp
11Data output eye map intersections505254%
12Operating temperature102550°C


Precautions for use
Connection and setting: When using the error meter, the optical communication equipment should be correctly connected to the test, and the appropriate parameters should be set according to the test requirements, such as signal rate, code type, etc.


Monitoring and analysis: After starting the error meter, the number and type of error codes should be closely monitored, and the cause of error codes should be found through the analysis function.


Adjustment and optimization: Perform necessary adjustments and optimization based on the analysis result, such as replacing optical modules and optimizing optical fiber connections.


Repeated testing: In order to verify the effect of the adjustment, repeated testing can be performed several times to ensure the reliability of the test results.


Product Tags: 12-Channel Optical Error Meter   15G Optical Error Meter   622M~15.0G Optical Error Meter  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: Guangzhou UC Instruments., Co. Ltd.
Subject:
Message:
Characters Remaining: (80/3000)