4 Channel Parallel Tape Display 10G Full Rate Error Meter BERT
Basic features of the U9210S: 1. Four-channel parallel PG and ED; Single ended clock output. 2. PG and ED support 37 rate points ranging from 0.6144 to 15.0
Gbps. 3, support code type: PRBS7 / PRBS 9 / PRBS 15 / PRBS 23 / PRBS 31. 4, support continuous error detection and timing error monitoring. 5, with display screen, support panel button operation. 6. Communication mode: USB HID (drive free) or USB-com.
The screen interface is as follows (for reference only).
Instrument name | U9210S | parameter | minimum | typical | maximum | unit | Data rate | 0.6144 | 0.614,0.622,1.25,2.5,5.0,9.953,10.00,10.3125,10.52,11.09,11.32,11.7,12,12.5,14.025,14.5,15Etc. | 15.0 | Gbps | Number of channels |
| 5 (4 electrical ports, 1 optical port, PG and ED supported) |
|
| Code type |
| PRBS7,PRBS9,PRBS15,PRBS23,PRBS31 |
|
| Rise and fall time (20% to 80%) |
| 18 | 23 | ps | Pattern reversal |
| Supports signal reversal at the transmitting and receiving ends |
|
| Signal differential output amplitude | 200 | 600 | 1000 | mV | Data output jitter (RMS) |
| 1.5(10.3125G下) |
| ps | Data input/output interface |
| Differential, AC coupling, 50 ohm impedance, SMA |
|
| Clock output | 100 | 156.25 | 156.25 | MHz | Data signal input sensitivity |
| 50 |
| mVpp | Data output eye graph crossing point (difference) | 49 | 50 | 54 | % | USB HID response time |
| 10 |
| ms | Operating temperature | 10 | 25 | 50 | °C | Operating voltage (AC) | 180 | 220 | 250 | V |
|