Server-Simulated Rack-Mounted Load Bank AC240V 20kW Data Center Commissioning

Server-Simulated Rack-Mounted Load Bank AC240V 20kW Data Center Commissioning

Model Number KL20
Brand Name King
Certification CE/ISO
Price USD1250-1500/Unit
Place of Origin China
Minimum Order Quantity 1
Payment Terms L/C, T/T
Packaging Details Plywood Cases
Supply Ability 100 Units per 60 days
Delivery Time 60 days
Detailed Product Description
Technical Specifications
Rated Voltage & FrequencyAC Single-phase, AC240V 60Hz
Rated PowerResistive Load: 20kW @ 240V/60Hz
Power Factor1
Load Stepo Respectively:
o Channel A: FAN, 1kW, 1kW;
o Channel B: 3kW;
o Channel C: 3kW;
o Channel D: 3kW;
o Channel E: 3kW;
o Channel F: 3kW;
o Channel H: 3kW.
o Note: 1. Step power is the nominal power at 240V, excluding fan power; 2. When the input voltage is lower than
the rated voltage, the power is calculated according to Ohm's Law.
Interface Description1. Chassis rear panel; Input interface is a 3-core power socket (C20); Testing cable load end connector is C19;
2. The load utilizes a manual control method, equipped with 9 miniature circuit breakers (MCBs), of which 1 controls the fan and 8 control the load steps.
3. The 7 input ports can be arbitrarily connected to different power sources; if Channel A loses power, the load will not work.
Insulation ClassF Class
Load Step Accuracy±5%
Full Load Accuracy±3%
Wiring Method3-core power socket (C20); Wiring Location: Chassis real panel
Protection LevelIP20
Chassis ColorBlack
Operation ModeContinuous operation
Handling MethodCan be carried using the front panel insatallation handles, equipped
with mounting ears
Main Component Brands
Step SwitchesSchneider
Low Voltage ContactorsSchneider
Power Unit MaterialNickel-Chromium Alloy
Key Features
High-Quality ResistorsAlloy Resistors
Cooling SystemForced-air Cooling, front air intake, rear air exhaust
Control ModesLocal Manual Control or RS232/RS485
Safety Protection
Over-temperature AlarmAutomatic unload and alarm when temperature is over
safety thresholds
Fan Failure ProtectionMachine could not load testing before power of fan is
power on
Emergency StopUser can press emergency stop button in panel to unload
immediately when load bank is abnornal while working
Short Circuit ProtectionThe load circuit is equipped with a fuse to avoid damage
to the equipment by short-circuiting the load or excessive
current
Applications
Generator Set TestingPrevent "Wet Stacking" and perform full-load exercises
UPS & Battery Bank
Maintenance
Periodic discharge testing to verify actual capacity
Data Center AcceptanceSimulate server heat and electrical loads for
comprehensive commissioning
R&D/LaboratoryFor performance burn-in and stress testing of power
electronics
Product Informaiton
Product Size431x444.50x500mm
Product Weight32 Kgs
Operating Environment Parameters
Operating Temperature-10°C to +40°C
Storage Environment-15°C to +50°C; 20%RH to 90%RH
Altitude<1500 meters
Atmospheric Pressure86~106kPa

 

Product Tags: Server-Simulated Resistive Load Bank   Rack-Mounted Load Bank AC240V   20kW Data Center Load Bank  