Double Beam AAS Atomic Absorption Spectrophotometer Wayeal

Double Beam AAS Atomic Absorption Spectrophotometer Wayeal

Brand Name Wayeal
Model Number AA2300
Certification ISO
Place of Origin Anhui, China
Minimum Order Quantity 1
Price Negotiation
Supply Ability 30 Pieces Per Month
Delivery Time 30 days
Packaging Details Wooden Case
Product Name Atomic Absorption Spectrophotometer AA2300
Injection bits 108
Heating rate 3000°C/s
Injection volume 1-200μL
Zero drift(Abs/30min) ±0.002/30min
Spectral bandwidth 0.1, 0.2, 0.4, 1.0, and 2.0nm
Detailed Product Description

Hollow Cathode Lamp and Nebulizer Double Beam AAS Atomic Absorption Spectrophotometer
 
Introduction of Atomic Absorption Spectrophotometer
Atomic absorption spectroscopy (AAS) is based upon the principle that free atoms in the ground state can absorb light of a certain wavelength. These very specific wavelengths give the technique excellent specificity and detection limits in the AAS analysis. 

 
Parameters of Atomic Absorption Spectrophotometer AA2300

Hollow Cathode Lamp and Nebulizer Double Beam AAS Atomic Absorption Spectrophotometer

Wavelength range(nm)185-900nm
Wavelength indication error(nm)±0.15nm
Wavelength repeatability(nm)≤0.05 nm
Spectral Bandwidth0.1, 0.2, 0.4, 1.0, and 2.0nm
Zero Drift±0.002/30min
Instantaneous noise(Abs)≤0.002 Abs
Flame Atomizer 
Detection limitCu: ≤0.002μg/mL
RepeatabilityRSD≤0.25%
Graphite Furnace Atomizer 
Detection limit(Graphite Furnance: Cd pg)≤0.3pg
RepeatabilityRSD≤1.5 %
Heating temperatureroom temperature -3000°C or so
Heating rate3000°C/s
Autosampler 
Injection bits108
Linear>0.999
Injection volume1-200μL
Injection volume repeatability≤0. 1%
Result repeatability≤1.5%
Background correctionDeuterium lamp
Lamp position8

 
Features of Atomic Absorption Spectrophotometer AA2300

1.Stability: Double-beam system can automatically compensate the light source drift and wavelength drift caused by the variation of temperature (with the function of the eliminating the affection of wavelength drift on the base line stability) and electronic circuit drift so as to reach a good basic line stability.
2.Quickly: The cathode lamp needs not be pre-heated for long time and sample can be analyzed immediately. It is the preferable instrument chosen by users to conduct analysis of multiple kinds of elements and fast analysis of samples.
3.High precision of measurement: Gas path system is equipped with precision pressure stabilizing and current stabilizing devices to reach stable flame and low noise. Specially designed fine light beam passes through the flame to ensure a high precision analytical test and low characteristic concentration.
4.Long-life and anti-corrosive atomization system:The burner is made of new type titanium alloys, anti-corrosive and fast thermal equilibrium. It meets the requirement of measurement sensitivity without water-cooling.


Applications of Atomic Absorption Spectrophotometer
Atomic absorption spectroscopy is an extremely important analytical method in the field of analytical chemistry. It has been widely used in metallurgy, food, agriculture, chemical industry, environmental protection and materials science. At present, atomic absorption spectrophotometer has become one of the tools for metal element analysis and trace analysis.


Product Tags: Double Beam AAS Spectroscopy   Dual Beam Atomic Absorption Spectrophotometer   Double Beam Double Beam Atomic Absorption Spectrophotometer AAS  