Introduction of High Performance Liquid Chromatography
Instrument:
This HPLC instrument is equipped with a variety of detectors,
including UVD, DAD, ELSD, FLD, and RID, providing users with a
range of options to suit their specific analytical needs. Whether
you are looking to detect compounds at different wavelengths, or
need to measure low-level analytes, this instrument has you
covered. With its powerful detectors and efficient sample processing
capabilities, this instrument is sure to deliver accurate and
precise results every time.
Technical Data of High Performance Liquid Chromatography Instrument
Manufacturer: | Wayeal |
Product Name: | Liquid Chromatography Instrument |
Working Power Supply | 220V, 50Hz |
Ambient Temperature | 10~40°C |
Relative Humidity | 20~85% |
Qualitative Repeatability | ≤0.2% |
Quantitative Repeatability | ≤0.4% |
High Pressure Constant Flow Pump | |
Flow Rate Range | 0.001~10.000mL/min |
Setting Step | 0.001mL/min |
Pressure Range | 0~42MPa |
Pressure Pulsation | 0.1MPa |
Flow Rate Set Error | ±0.2% |
Flow Rate Stability | RSD≤0.06% |
Gradient Error | ±1% |
Column Oven | |
Temperature Control Range | 4~85°C |
Temperature Stability | ±0.02°C |
Temperature Setting Resolution | 0.1°C |
Autosampler | |
Injection Volume Repeatability | <0.5%RSD |
Linearity | >0.9999 |
Cross Contamination | <0.002% |
Injection Volume Accuracy Error | ±1% |
Sample Positions | 120 |
Injection Volume | 1~100μL |
UV Detector | |
Baseline Noise | ≤2.0*10-6Au |
Baseline Drift | ≤1*10-5Au/h |
Mini Detection Concentration | ≤3.0*10-9g/mL (naphthalene/methanol) |
Spectral Range | 188~900nm |
Wavelength Error | ≤±0.1nm |
Wavelength Repeatability | ≤±0.1nm |
Linearity Range | ≥103 |
DA Detector | |
Baseline Noise | ≤4*10-5Au |
Baseline Drift | ≤3*10-5Au/h |
Mini Detection Concentration | ≤2*10-8g/mL |
Spectral Range | 190~800nm |
Wavelength Error | ≤±0.1nm |
Wavelength Repeatability | ≤±0.1nm |
Linearity Range | ≥ 104 |
ELS Detector | |
Baseline Noise | ≤ 0.0037mV |
Baseline Drift | ≤ 0.0026mV/30min |
Evaporation Gas Flow Range | (0 ~ 3) SLM |
Atomization Temperature Range | Room temperature ~ 90℃ |
Evaporation Temperature Range | Room temperature~110℃ |
Detection Chamber Temperature Range | Room temperature~60℃ |
Input Air Pressure | (4 ~ 7) bar |
FL Detector | |
Baseline Noise | ≤ 5×10-6 FU |
Baseline Drift | ≤ 2 × 10-5 FU/30min |
Spectral Range | (200 ~ 650) nm |
Wavelength Error | ± 0.1 nm |
Linearity Range | ≥ 104 |
RI Detector | |
Detection Range | 0.25 ~ 512 μRIU |
Linearity Range | ≥ 600 μRIU |
Response Time | 0.1, 0.25, 0.5, 1, 1.5, 2, 3, 6 sec; |
Cell Volume | 8μL |
Applications of High Performance Liquid Chromatogaphy Instrument:
The Wayeal LC3200 HPLC instrument is designed for analytical and
preparative chromatography applications. It is an ideal choice for
researchers and scientists who require high-resolution separation
and analysis of complex mixtures. The Wayeal LC3200 HPLC instrument is suitable for use in various
industries such as pharmaceuticals, biotechnology, food and
beverage, environmental analysis, and many others. It can be used
for the analysis of drugs, proteins, peptides, nucleic acids,
polymers, and other complex mixtures.