Binary High Pressure Gradient System for HPLC High Performance
Liquid Chromatography System
Introduction of Liquid Chromatography Instrument
High-performance liquid chromatography (HPLC; formerly referred to
as high-pressure liquid chromatography), is a technique in
analytical chemistry used to separate, identify, and quantify each
component in a mixture.
It relies on degas-unit and two pumps to pass a solvent referred to
as a “ mobile phase” (e.g. water, acetonitrile, methanol etc.) and
sample mixture through a column referred to as a “ stationary
phase” filled with a solid adsorbent material, is typically a
granular material made of solid particles (e.g. silica, polymers,
etc.). Each component in the sample interacts slightly differently
with the adsorbent material, causing different flow rates for the
different components and leading to the separation of the
components as they flow out the column.
Parameters of Liquid Chromatography Instrument
| Manufacturer: | Wayeal |
| Product Name: | Liquid Chromatography Instrument |
| Working Power Supply | 220V, 50Hz |
| Ambient Temperature | 10~40°C |
| Relative Humidity | 20~85% |
| Qualitative Repeatability | ≤0.2% |
| Quantitative Repeatability | ≤0.4% |
| High Pressure Constant Flow Pump | |
| Flow Rate Range | 0.001~10.000mL/min |
| Setting Step | 0.001mL/min |
| Pressure Range | 0~45MPa |
| Pressure Pulsation | 0.1MPa |
| Flow Rate Set Error | ±0.2% |
| Flow Rate Stability | RSD≤0.06% |
| Gradient Error | ±1% |
| Column Oven | |
| Temperature Control Range | 4~85°C |
| Temperature Stability | ±0.02°C |
| Temperature Setting Resolution | 0.1°C |
| Autosampler | |
| Injection Volume Repeatability | <0.5%RSD |
| Linearity | >0.9999 |
| Cross Contamination | <0.002% |
| Injection Volume Accuracy Error | ±1% |
| Sample Positions | 120 |
| Injection Volume | 1~100μL |
| UV Detector | |
| Baseline Noise | ≤2.0*10-6Au |
| Baseline Drift | ≤1*10-5Au/h |
| Mini Detection Concentration | ≤3.0*10-9g/mL (naphthalene/methanol) |
| Spectral Range | 188~900nm |
| Wavelength Error | ≤±0.1nm |
| Wavelength Repeatability | ≤±0.1nm |
| Linearity Range | ≥103 |
| DA Detector | |
| Baseline Noise | ≤4*10-5Au |
| Baseline Drift | ≤3*10-5Au/h |
| Mini Detection Concentration | ≤2*10-8g/mL |
| Spectral Range | 190~800nm |
| Wavelength Error | ≤±0.1nm |
| Wavelength Repeatability | ≤±0.1nm |
| Linearity Range | ≥ 104 |
| ELS Detector | |
| Baseline Noise | ≤ 0.0037mV |
| Baseline Drift | ≤ 0.0026mV/30min |
| Evaporation Gas Flow Range | (0 ~ 3) SLM |
| Atomization Temperature Range | Room temperature ~ 90℃ |
| Evaporation Temperature Range | Room temperature~110℃ |
| Detection Chamber Temperature Range | Room temperature~60℃ |
| Input Air Pressure | (4 ~ 7) bar |
| FL Detector | |
| Baseline Noise | ≤ 5×10-6 FU |
| Baseline Drift | ≤ 2 × 10-5 FU/30min |
| Spectral Range | (200 ~ 650) nm |
| Wavelength Error | ± 0.1 nm |
| Linearity Range | ≥ 104 |
| RI Detector | |
| Detection Range | 0.25 ~ 512 μRIU |
| Linearity Range | ≥ 600 μRIU |
| Response Time | 0.1, 0.25, 0.5, 1, 1.5, 2, 3, 6 sec; |
| Cell Volume | 8μL |
Application of Liquid Chromatography Instrument
Food, medicine, environment, agriculture and scientific research.