Optical Titanium Alloy Dissolved Oxygen Monitor Dissolved Oxygen
Sensor For Seawater Farms
Dissolved oxygen sensors and meters are commonly used in various
industries to measure the amount of oxygen present in a liquid,
typically in water. Optical sensors are commonly used in
aquaculture to measure DO. They are based on the principle of
fluorescence, where the sensor contains a dye that fluoresces in
response to oxygen. The intensity of the fluorescence is directly
proportional to the concentration of dissolved oxygen. Optical
sensors are very accurate, and they respond quickly to changes in
DO levels. They are also very stable and require very little
maintenance. However, they can be expensive compared to other types
of sensors.
Dissolved Oxygen Sensor Brief Introduction
The DS380 series of fluorescent dissolved oxygen sensors use a new type of fluorescence lifetime technology and
high-performance fluorescent materials. The fluorescent dissolved oxygen sensor is based on the quenching
principle of the specific fluorescence of a specific substance in
physics. Blue light from a light-emitting diode (LED) illuminates
the fluorescent material on the inner surface of the fluorescent
cap, and the fluorescent material on the inner surface is excited
to emit red light by detecting the phase difference between red and
blue light and the internal calibration value. The ratio is
calculated to calculate the concentration of oxygen molecules, and
the final value is automatically compensated by temperature and
pressure.
Features of Fish Tank Dissolved Oxygen Sensor:
-0-20mg/L or 0-200% saturation
-0~50 °C; IP68 protection level
-No film, no electrolyte, no polarization
-No need to consume oxygen, no flow rate
-Built-in temperature sensor, automatic temperature compensation
-Free from chemical interferences such as sulfides
-Small annual drift, fast response, and more accurate measurement
-Free of maintenance, longer application cycle, and lower cost of
use
-Fluor cap replacement is simple
-Support RS-485, MODBUS protocol
Technical Specifications of Fish Tank Dissolved Oxygen Sensor:
Item | Parameters |
Model | DS380 |
Principle | Fluorescence analysis method |
Measuring range | 0~20mg/L or 0-200% saturation |
Response time | 3 sec |
Accuracy | 1% |
Protection level | IP68 |
Installation | Submersible |
Temperature sensor | NTC |
Temperature range | 0~50°C |
Temperature accuracy | ±0.2°C |
Output | Support RS-485, MODBUS protocol |
Power supply | DC 6~12V, current <50mA |
Size | Φ26*155 mm |
Probe cable length | Default 5 m, customized 10m, 15 m and 30 m cable |
Fluorescent cap life | 1 year |
Maximum working pressure | 3bar |
Housing material | SS316/Titanium alloy |