High Temperature Dissolved Oxygen Sensor Probe 12V Titanium

High Temperature Dissolved Oxygen Sensor Probe 12V Titanium

Brand Name Desun Uniwill
Model Number DS-380
Place of Origin China
Minimum Order Quantity 0~100 pcs
Price $280.00 - $360.00/ Piece
Payment Terms L/C, D/A, D/P, T/T
Supply Ability 0~1000 pcs
Delivery Time 7~ 15 working days
Packaging Details Carton packaging
Measuring range 0~20mg/L
Response time 3 seconds
Protection level IP68
Power supply DC 6~12V
product material POM/SS316/Titanium
Power consumption < 0.5 W
Calibration method One or Two-point calibration
Accuracy 1%
Maximum working pressure 6bar
Fluorescent cap life 1 year
Detailed Product Description

Fluorescence Analysis Dissolved Oxygen Sensor Probe 12V Titanium

Features

* 0-20mg/L or 0-200% saturation * 0~50 °C;
*IP68 protection level * No film, no electrolyte, no polarization
* No need to consume oxygen, no flow rate
* Built-in temperature sensor, automatic temperature compensation

Technical Parameters

ItemParameters
ModelDS380
PrincipleFluorescence analysis method
Measuring range0~20mg/L or 0-200% saturation
Response time3 sec
Accuracy1%
Protection levelIP68
InstallationSubmersible
Temperature sensorNTC
Temperature range0~50°C
Temperature accuracy±0.2°C
OutputSupport RS-485, MODBUS protocol
Power supplyDC 6~12V, current <50mA
SizeΦ26*155 mm
Probe cable lengthDefault 5 m, customized 10m, 15 m and 30 m cable
Fluorescent cap life1 year
Maximum working pressure6bar
product materialPOM/SS316/Titanium alloy
Calibration methodOne or Two-point calibration
Power consumption< 0.5 W

 

 

 

 

 

 

 

Fluorescent cap daily storage

Put it in a protective cover with a moist sponge when not in use, so that the sensor stays wet for a long time.
If the head of the sensor's fluorescent cap is dry for a long time, it will cause drift of the measurement result, so it needs to be immersed in water for 48 hours before continuing to work.