Room Environment Power Distribution Monitoring Controling
Management System Power Distribution Room Environment Monitoring Controling
Management System Outdoor Indoor According to the actual situation of the distribution room.
Independent research and development of TimeWaveCloud distribution
room dynamic environment monitoring platform and intelligent energy
consumption dynamic environment monitoring unit (iFSU). Realize
load operation monitoring such as current, voltage, power and power
factor, bus temperature monitoring, cable temperature monitoring,
environmental monitoring, access control, air conditioning/fan
control, etc. Realize power environment monitoring. Avoid power
distribution equipment operation failure caused by uncontrolled
operation environment. Extend the service life of the equipment.
Ensure the safety of maintenance personnel.
- Introduction to system functions and features
1. Centralized control: iFSU centralized control; 2. Communication mode: Uplink 4G (CAT1)/WLAN, downlink
RS485/wireless; 3.Software architecture: B/S architecture+applet/APP+standard API; 4.System integration: Power monitoring, environmental monitoring,
security monitoring, bus/cable temperature monitoring are
integrated; 5.Real time monitoring: Monitoring and displaying the voltage,
current, active power, reactive power, power factor and other
operating parameters of the equipment in the
power distribution room. And monitoring the environmental operation
parameters of the power distribution room; 6. Real time alarm: Alarm for abnormal electrical parameters,
temperature, humidity, equipment failure or communication failure; 7. Alarm mode: Pop-up alarm, voice alarm, SMS, WeChat alarm,
audible and visual alarm; 8. Data query: Display and query the real-time operation
information of the power distribution room; 9. Display mode: Bulletin board display, chart and curve graph
display; 10. Operation report: Daily, monthly, annual and operation report; 11. Permission management: Define the permissions of users at
different levels to ensure reliable and safe operation; 12. Layout: Cloud platform, local layout; - Related hardware products
Model | Product picture | Major functions | Intelligent energy consumption power environment monitoring unit (IFSU) (TW-IFSU type) | | Data upload interface: RJ45 network interface/RS485/CAT1/NB-IOT/LORAWAN. Switching input: 8 circuits (used for switching value alarm of smog
detector, door magnet, water immersion, 220V mains power failure,
etc.) | DDSD1150/DTSD1150Type three-phase multi-function electric watt hour meter | | It can measure positive active, negative active electric
energy and A/B/C phase electric energy. It can measure total
power, total power factor,A/B/C current,A/B/C voltage,A/B/C
power factor. | Three phase four wire electronic watt hour meter electronic watt hour meter (DTS150 type) | | It integrates the functions of metering,alarm,display,switching,
monitoring power parameters and overload. The combined active
and reactive power can be measured. It has the functions of
measuring voltages,currents,power factors,remote centralized
meter reading,etc | LoRa temperature and humidity sensor | | It provides cost-effective LoRaWAN terminal nodes for various work
scenarios. It is an IP64 enclosure. Long operation time and low
maintenance cost.It is very suitable for outdoor use. | LoRa smog detector | | The alarm information that can be sent includes:fire, fault,
undervoltage, self inspection, etc. They have universality,
extensibility and readability with the communication protocol
adopted by the upper layer. | LoRa water immersion detector | | It is an alarm device for water leakage detection and is compati
with LoRaWAN protocol.The radio transmission is based on
LoRa long-distance technology. According to the required
behavior and status, the sensor can transmit information and
data to the server. | LoRa Cable temperature measuring device | | A cable temperature measuring devicebased on LoRaWAN. With
temperature detection, data reporting, remote monitoring and other
functions. |
- User presentation overview: it displays the power consumption
profile, site profile, operation status, curve and alarm of all
users. Users can be selected from the drop-down box;
- Temperature information: it displays the curve of the ambient
temperature in the substation room, the collection time, the
average value and other information;
- The system provides the pre alarm configuration function, which can
realize the configuration and management of equipment alarm
(equipment offline, analog quantity out of limit, temperature out
of limit, etc.) strategies. You can set the trigger time of the
alarm, the type of the alarm, whether to enable SMS, audible and
visual alarm, etc.
- Pre alert Info: The alert information of the site is recorded here.
Alarm includes: voltage, current and other line crossing alarm;
Switching value alarm; Event alarm; Other alarms. It can record the
total number and category of alarms, and filter alarm information
according to different search conditions.
- User management: 4 sub items, including user permission setting,
operation record, control record and system record. User
permissions can be set and changed under high-level user