China Laboratory Testing Machines manufacturer
Dongguan Lixian Instrument Scientific Co.,LTD
Dongguan Lixian Instrument Scientific Co.,LTD have 22 years of experience in design, research and development. Factory covers an area of 6000 square meters, Total number of employees more than 60 in
3
Home > Products > Mask Testing Equipment >

OBM Multiscene Mask Testing Equipment , ASTM Bacterial Filtration Efficiency Tester

OBM Multiscene Mask Testing Equipment , ASTM Bacterial Filtration Efficiency Tester

Brand Name Lixian
Model Number HZ-9514
Certification CE/ISO
Place of Origin China
Minimum Order Quantity 1 set
Payment Terms L/C, T/T, D/A, D/P, Western Union, MoneyGram
Supply Ability 300 sets /per month
Packaging Details Standard export wooden case
Model HZ-9514
Customized support: OEM, ODM, OBM
Origin China
Power Electronic
Application Mask, Guaze Mask
MOQ 1 Set
Standards ASTM F2101 - 19 , YY/T 0969-2013, Q/0212 ZRB003-2011
Warranty 1 year/12months
Payment method L/C,T/T,D/A,D/P
Detailed Product Description

HZ-9514 Bacterial Filtration Efficiency Tester (BFE)

Equipment Overview

It used to test the percentage of respirator material removed from the bacteria - containing suspended particles at a specified flow rate. The dual-air path sampling method improves the accuracy of sampling, which is applicable to the performance test of bacterial filtration efficiency of medical surgical masks by metrological verification departments, scientific research institutes, medical mask manufacturers and other relevant departments

 

 

Standardization

  • Q/0212 ZRB003-2011 Surgical mask Bacterial filtration efficiency (BFE) detector
  • YY0469-2004 Surgical mask Bacterial filtration efficiency (BFE) detector technical request
  • YY/T 0969-2013 Standard for bacterial detection of disposable medical masks
  • ASTMF2100 Performance specifications of materials for medical masks
  • ASTM F2101 - 19 Standard Test Method for Evaluating the Bacterial Filtration Efficiency (BFE) of Medical Face Mask Materials
  • EN 14683-2014 Medical face masks - Requirements and test methods

 

Technical Parameters

 

 

Main ParameterParameter RangeResolutionMax Error
A Sampling rate28.3L/min0.1L/minExceed±2.5%
B Sampling rate28.3L/min0.1L/minExceed±2.5%
Spray flow(8~10)L/min0.1L/minExceed±5.0%
Peristaltic pump flow(0.006~3.0)mL/min0.001ml/minExceed±2.5%
A Flowmeter front pressure(-20~0)kPa0.01kPaExceed±2.5%
B Flowmeter front pressure(-20~0)kPa0.01kPaExceed±2.5%
Spray flowmeter front pressure(0~300)kPa0.1kPaExceed±2.5%
Air chamber negative pressure(-90~-120)Pa0.1PaExceed±2.0%
operating temperature(0~50)℃
Negative pressure(-50~-200)Pa
Data storage capacity>100000 groups
Characteristics of High Efficiency Air FilterThe filtration efficiency of particles above 0.3um is ≥99.99%
Median mass diameter of aerosol generatorMean Corpuscular Diameter(3.0±0.3)μm, geometric standard deviation≤1.5
Dual channel 6 - stage Anderson sampler captures particle sizeⅠclass>7μm,Ⅱclass(4.7~7)μm,Ⅲ class(3.3~4.7)μm,Ⅳclass(2.1~3.3)μm,Ⅴ class(1.1~2.1)μm,Ⅵclass(0.6~1.1)μm
Aerosol chamber specifications(Length600×Dia85×Thickness 3)mm
Total number of particles in positive quality control sampler(2200±500)cfu

 

 

 