BPZ93420-III smart Pressure Transmitter
Introduction of smart pressure transmitter:
BPZ93420III pressure transmitter adopts the HT series silicon
piezoresistive isolation oil-filled core as the signal measuring element. The signal
processing circuit converts the sensor signal into a standard output signal. The
product undergoes rigorous testing and aging screening of components, semi-finished,
and finished products, ensuring stable and reliable performance with strong
anti-interference capability. The pressure interface of the pressure transmitter is
available in various forms
Product Features of smart pressure transmitter:
1. Wide measuring range, diverse pressure interface forms, and IP65
protection level.
2. Various output signal forms, adjustable and displayable
3. Adjustable zero point and full scale
4. Core utilizes high-precision and high-performance diffused
silicon piezoresistive pressure sensors
Applications of smart pressure transmitter:
1. Suitable for measuring the pressure of non-corrosive gases and
liquids in 316L stainless steel
2. Petroleum, chemical, metallurgy, power, and hydrology
3. Pressure measurement and control in harsh outdoor industrial
environments
4. Used in hydraulic and pneumatic control systems
Performance Parameters of smart pressure transmitter |
Measurement Range | -100kPa…0kPa ~10kPa…100MPa |
Pressure Type | Gauge Pressure, Absolute Pressure, Sealed Pressure |
Overload | ≤ 1.5 times of the rated range |
Accuracy @ 25ºC | ±0.25% (Typical) ±0.5% (Maximum) |
Repeatability | ≤±0.1%FS |
Hysteresis | ≤±0.1%FS |
Long-Term Stability | ±0.1%F.S/Year(Typical) ±0.2%F.S/Year(Maximum |
Zero Point Temperature Drift | ±0.02%F.S/ºC(≤100KPa) ±0.01%F.S/ºC(>100KPa) |
Full Scale Temperature Drift | ±0.02%F.S/ºC(≤100KPa) ±0.01%F.S/ºC(>100KPa) |
Frequency Response | 2.4Khz |
Compensation Temperature | 0-70ºC(≤10mpa,customizable) |
Operating Temperature | -20ºC~80ºC |
Storage Temperature | -40ºC~120ºC |
Vibration | 10g,55Hz ~ 2kHz |
Housing Material | Cast aluminum |
Diaphragm Material | 316L |
Insulation Resistance | 100MΩ 100VDC |
Protection Rating | IP65 |
O-Ring Seal | Fluoro rubber |
Weight | ~1.2kg |
Output Signal | Supply Voltage | Output Type |
4~20mA | 12~30VDC | 2/3/4 wire |
0~10/20mA | 3 wire |
0/1~5V |
0/1~10V |
0.5~4.5V | 5VDC |
RS485 Communication Protocol | 3.6~30V / Battery | 4 wire |
1. When selecting the product, please ensure that the medium to be
measured is compatible with the contact parts of the product.
2. When placing an order, please note that explosion-proof type
products do not include digital display heads.
3. When ordering transmitters with an LCD or LED display head, the
power supply for the transmitter should not be lower than 20VDC.
4. To ensure reliable operation of the product, it is recommended
that users install lightning protection devices on-site and ensure
that the product and power supply are reliably grounded.
5. The rated working temperature range of the Fluoro rubber O-ring
is -20ºC to 250ºC. When the product's operating temperature is
below -20ºC, it is necessary to choose an EPDM O-ring seal.
6. The default cable length is 1.5m, available in three materials.
If not specified, it will be supplied with polyethylene cable
material. If you require a different cable material, please specify
it in the order.
7. For special requirements such as strong vibration, instantaneous
impact force, strong electromagnetic or radio frequency
interference, please inform our company and specify them in the
order.
Order Guide |
BP93420XX | Pressure Transmitter |
| Code | Outline Construction |
IB | General Pressure Transmitter | IX | Display Pressure Transmitter |
IE | Shock-resistant Aviation Pressure Transmitter | IIC/III | Industrial General/ Display Pressure Transmitter |
IF | Moisture-proof Pressure Transmitter | IIE/IIIE | General/Display Pressure Transmitter |
IN | Air Conditioning Dedicated Pressure Transmitter | | |
IC | High-temperature Pressure Transmitter | | |
IQ/IQT | Large Diaphragm /High-temperature Pressure Transmitter | | |
| Measurement Range | -100kPa…0kPa ~ 35kPa…3.5MPa |
(0-X)Kpa or MPa | X: Indicates the Actual Measuring Range |
| Code | Power Supply |
D1 | 24VDC |
D2 | 5VDC |
D3 | Other |
| Code | Output Signal |
S1 | 4~20mADC | S5 | 0~20mADC |
S2 | 1~5VDC | S6 | 0~10VDC |
S3 | 0~5VDC | S7 | 0.5~4.5VDC |
S4 | 0~10mADC | | |
| Code | Pressure Connection |
J1 | M20×1.5 |
J2 | G1/2 |
J3 | G1/4 |
J4 | 7/16-20UNF |
J5 | Other |
| Code | Electrical Connection |
B1 | Hirschmann |
B2 | PG7 Plug |
B3 | Sealed Cable Output |
B4 | 2088 Industrial Casing |
B5 | 2088 Industrial Casing with Display |
B6 | Other |
| Code | Pressure Type |
G | Gauge Pressure |
A | Absolute Pressure |
S | Sealed Reference Pressure |