110-240v Traffic Inductive Dual Channel Loop Vehicle Detector With
15uh-2000uh Sensitivity
Professional 110-240VAC Double Channel Vehicle Loop Detector For
Activating Card Dispensers in Parking Lots
JUTAI introduces a versatile underground loop detection system,
capable of serving as a dual-channel loop detector. With one unit
accommodating two-channel loop coils, users can harness this
technology to activate entrance card dispensers while
simultaneously ensuring barrier gate safety closure. Offering
unparalleled functionality, Jutai provides the ultimate solution
for driveway gate control systems and parking management.
Key Features
Compact Size: Engineered with a compact housing design, this
detector seamlessly integrates into any traffic detection system
while meeting industry standards for features and functionality.
Diagnostic Capabilities: Enjoy comprehensive diagnostic
capabilities, facilitating accurate diagnosis of loop and
installation issues to ensure optimal performance.
Selectable Presence Time: Customize the output of the presence
relay to limit detection output to a fixed time (greater than 30
minutes) while a vehicle remains on the loop, enhancing operational
efficiency.
Loop Frequency Indication: Detect and eliminate interference
between adjacent loops/detectors with integral indication, enabling
frequency setting adjustments to optimize performance.
Direction Detection: Benefit from direction detection
functionality, where CH1 relay output is triggered when a vehicle
moves from CH1 to CH2, and CH2 relay output activates when the
vehicle moves from CH2 to CH1.
Sensitivity Selection: Adjust loop sensitivity and frequency using
7-way dip switches and 10-way dip switch settings, providing
flexibility to meet specific application requirements.
Enhance your parking lot management system with the Professional
110-240VAC Double Channel Vehicle Loop Detector from JUTAI.
Experience advanced functionality and seamless integration for
optimal performance and reliability.
Professional 110-240VAC Double Channel Vehicle Loop Detector: Modes
of Operation
The LD-200 series detector offers versatile operation modes,
catering to various application requirements:
Presence Mode: In this mode, the detector remains active as long as
a vehicle is present within the loop detection area. It provides a
continuous output signal as long as the vehicle occupies the
detection zone.
Pulse Mode: In Pulse Mode, the detector generates a single pulse
output signal when a vehicle is detected within the loop area. This
mode is suitable for applications where a single signal pulse is
required upon vehicle detection.
AB Logic Presence Mode (Barrier Operation): This mode employs AB
logic, where the detector triggers the barrier operation based on
the presence of vehicles. It ensures smooth barrier operation,
allowing vehicles to pass through efficiently and safely.
AB Logic Pulse Mode (Counting Logic): In AB Logic Pulse Mode, the
detector utilizes AB logic for pulse output signals. It enables
counting logic, where each pulse represents a detected vehicle,
facilitating accurate vehicle counting and monitoring.
Professional 110-240VAC Double Channel Vehicle Loop Detector
Specifications
Specification | Details |
---|
Loop Inductance | 20-2000μH |
Sensitivity | 8-way selectable<br>Highest: 0.015% DL/L<br>Lowest:
0.8% DL/L |
Frequency | Four-step switch selectable: 20-80KHz |
Power Requirements | 110-240VAC (48 to 62Hz)<br>12-24VADC (48 to 62Hz) |
Operation Temperature | -40℃ to +70℃<br>(-111℉ to +158℉) |
Fault Output | - Blinks slowly: Possible short circuit or insufficient number of
turns<br>- Blinks faster: Possible open loop or excessive
number of turns |
Response Times | 10-90MS |
Visual Indications | - Power LED: Red<br>- Channel LED: Green |
Reset | Reset by push button on front of enclosure |
Relay Signal | Presence signal or pulse signal |
ABS (Automatic Sensitivity Boost) | Yes |
Direction Detection | CH1 and CH2 flow direction detection |
Loop Frequency | 4 settings (low, med-low, med-hi, high) |
Humidity | Up to 95% relative humidity without condensation |
Circuit Protection | Conformal coating over the PCB and all components |
Connections | Socket mount-11pin male (JEDEC B11-88) |
Size | 75mm x 43mm x 110mm |
Application:
- Automatic Gate
- Traffic Light System
- Gate Drive Mechanisms
- Operating Barriers
- Parking Guidance System
- Activating Card Dispensers in Parking Lots.
- Parking Barrier Control
- Vehicle Access Control
- Traffic Control System / Traffic Toll System
- Vehicle Counting System
- Motorised Gates and Doors.
- Security Bollards/ Rolling Shutters/Garage Doors
- Camera trigger
Connections
Indicators and Switches:
- Power LED (RED): Illuminates to indicate "Power ON."
- CH1 Detecting LED:
- Continuous illumination: Indicates vehicle detection.
- Slow blinking: Signals a loop short circuit or insufficient twists
after the loop.
- Fast blinking: Indicates a loop open circuit or excessive twists
after the loop.
- CH2 Detecting LED:
- Continuous illumination: Signals vehicle detection.
- Slow blinking: Indicates a loop short circuit or insufficient
twists after the loop.
- Fast blinking: Indicates a loop open circuit or excessive twists
after the loop.
Sensitivity Selection:
- Sensitivity and frequency adjustments are facilitated via a 7-way
dip switch and 10-way dip switch settings.
- Users can select from 8 different settings by adjusting the dip
switch positions based on the provided tables.
- Dip switches 6, 7, and 8 regulate CH1 sensitivity, with 0.8
representing the least sensitive and 0.015 indicating the most
sensitive setting.
- Dip switches 3, 4, and 5 control CH2 sensitivity, with 0.8
representing the least sensitive and 0.015 indicating the most
sensitive setting.
3. Switch 1=S1 : Channel 1 Loop Function Selection (10 way dip
switch)
(1)(Switch 1) DIP 1 & DIP 2 Special Sensitivity Increase For
Both Trailer (Both Channels).
(2)(Switch 1=S1) D3, D4, D5 and (Switch 2=S2) D1, D2 Setting
Special Functions (Mode1, 2, 3 Direction Detection. Mode 4, 5, 6
Normal mode, two loop detection are separated)
(3)(Switch 1=S1) D6 & D7 & D8 and (Switch 2=S2) D3 & D4
& D5 Setting CH1 and CH2 Sensitivity Selection (Eight Levels
Choices).
(4)(Switch 1=S1) D9 & D10 and (Switch2=S2) D6, D7 Setting
Frequency (20 K to 100 KHz).
*Reset Button: Kindly note that the LD-200 requires resetting each
time a setting change is applied to the Dip switches.
Installation Precautions and Troubleshooting:
- Coil Cutting Size and Embedding Guidelines are illustrated in the
diagram on the right.
- It is advisable to utilize ferromagnetic wires for the induction
coil, with a total length of up to 500 meters.
- The coil cutting size should be a rectangle with dimensions ranging
from 1.0 to 2.0 meters in length and 0.8 to 1.2 meters in width,
minimizing right angles at corners whenever possible.
- Recommended installation overview of basic typical coil turns
When installation, please keep the product plug and socket in the
vertical direction
Working Principle
Entry Process | Exit Process |
---|
1. Both loop coils are pressed as a car enters. | 1. Car passes by an inside UHF reader as it exits. |
2. LD-200/202 triggers the UHF reader at the entrance. | 2. LD-200/202 triggers the UHF reader, which reads the card ID. |
3. UHF reader sends the ID to the controller (AC-11). | 3. Controller verifies ID's validity and opens gate barrier. |
4. Controller outputs a relay signal to open the gate barrier. | 4. Car exits as barrier arm lowers automatically. |
5. Car enters and barrier arm lowers automatically. | |
6. LD-100/102 ensures safety and anti-smashing functionality during
this process. | 5. LD-100/102 provides safety and anti-smashing functionality. |
Direction Recognition
The Direction Recognition Function of LD-200/LD-202 ensures that
the detector does not trigger the signal again when the car passes
another UHF reader, recording only the entry or exit records in the
system.
Application
- JUTAI LD200/202 double channels vehicle loop detector series,
equipped with direction recognition function, suitable for many
single-channel entry and exit cases.
- Can connect to JUTAI One door controller (Model: AC-11), JUTAI gate
barrier (Model: BR-110), and JUTAI long-range RFID reader (Model:
PUHF-9), combined with high-temperature resistance loop coils
(Model: JTHT-11), ideal for single-channel entry/exit access
control systems.
Functionality as Two Independent Single-channel Loop Detectors
- LD-200/202 can function as two independent single-channel loop
detectors, suitable for standard one-in and one-out parking lots.
- One loop coil triggers the reader and reads the card, while the
other is dedicated to the barrier's anti-smashing function.
- This configuration reduces hardware costs associated with using
separate detectors for each function, offering potential
cost-saving benefits from an economic standpoint.
- Achieved by enabling the Independent Working Mode feature of the
LD-200/202, allowing it to operate effectively in this dual
capacity.