ONE-STOP SOLUTIONS FOR WIRES&CABLES - HENAN UME CABLE CO., LTD Over 30 years of Wires and Cables manufacture experience and Export to over 50 countries. 1. Applications ABC cables are especially used at areas where the cost of underground networks is expensive and also for electrification of rural areas like villages. Bundles can include one or two additional conductors for public lighting and control pair. 2. Standard ABC Cable NFC 33-209 ABC Cable BS 7870 ABC CABLE AS/NZS 3560.1 ABC Cable GB 12527 Product Parameters ABC Cable NFC 33-209 No. of Conductor and Cross Section Area | Phase Core | Neutral Core | Street Lighting Core | Complete Cable | No. and Section Area | No. of Wire | Dia. of Conductor (Approx.) | Insulation Thickness | No. and Section Area | No. of Wire | Dia. of Conductor (Approx.) | Insulation Thickness | No. and Section area | No. of Wires | Diameter of conductor | Insulation Thickness | Overall Diameter (Approx.) | Weight (Approx.) | mm2 | mm2 | No. | mm | mm | mm2 | No. | mm | mm | mm2 | No. | mm | mm | mm | kg/km | 2x16 | 2x16 | 7 | 4.8 | 1.2 | - | - | - | - | - | - | - | - | 14.2 | 126 | 2x25 | 2x25 | 7 | 6.0 | 1.4 | - | - | - | - | - | - | - | - | 17.6 | 194 | 2x35 | 2x35 | 7 | 7.0 | 1.6 | - | - | - | - | - | - | - | - | 20.4 | 266 | 2x50 | 2x50 | 7 | 8.1 | 1.6 | - | - | - | - | - | - | - | - | 22.6 | 341 | 4x16 | 4x16 | 7 | 4.8 | 1.2 | - | - | - | - | - | - | - | - | 17.2 | 252 | 4x25 | 4x25 | 7 | 6.0 | 1.4 | - | - | - | - | - | - | - | - | 21.2 | 388 | 4x35 | 4x35 | 7 | 7.0 | 1.6 | - | - | - | - | - | - | - | - | 24.6 | 533 | 3x25+54.6 | 3x25 | 7 | 6.0 | 1.4 | 1x54.6 | 7 | 9.45 | 1.6 | - | - | - | - | 23.6 | 496 | 3x25+54.6+1x16 | 3x25 | 7 | 6.0 | 1.4 | 1x54.6 | 7 | 9.45 | 1.6 | 1x16 | 7 | 4.8 | 1.2 | 24.9 | 560 | 3x25+54.6+2x16 | 3x25 | 7 | 6.0 | 1.4 | 1x54.6 | 7 | 9.45 | 1.6 | 2x16 | 7 | 4.8 | 1.2 | 26.6 | 624 | 3x35+54.6 | 3x35 | 7 | 7.0 | 1.6 | 1x54.6 | 7 | 9.45 | 1.6 | - | - | - | - | 26.1 | 604 | 3x35+54.6+1x16 | 3x35 | 7 | 7.0 | 1.6 | 1x54.6 | 7 | 9.45 | 1.6 | 1x16 | 7 | 4.8 | 1.2 | 27.2 | 668 | 3x35+54.6+2x16 | 3x35 | 7 | 7.0 | 1.6 | 1x54.6 | 7 | 9.45 | 1.6 | 2x16 | 7 | 4.8 | 1.2 | 28.7 | 732 | 3x50+54.6 | 3x50 | 7 | 8.1 | 1.6 | 1x54.6 | 7 | 9.45 | 1.6 | - | - | - | - | 28.1 | 716 | 3x50+54.6+1x16 | 3x50 | 7 | 8.1 | 1.6 | 1x54.6 | 7 | 9.45 | 1.6 | 1x16 | 7 | 4.8 | 1.2 | 28.9 | 780 | 3x50+54.6+2x16 | 3x50 | 7 | 8.1 | 1.6 | 1x54.6 | 7 | 9.45 | 1.6 | 2x16 | 7 | 4.8 | 1.2 | 30.3 | 844 | 3x70+54.6 | 3x70 | 12 | 10.0 | 1.8 | 1x54.6 | 7 | 9.45 | 1.6 | - | - | - | - | 32.2 | 940 | 3x70+54.6+1x16 | 3x70 | 12 | 10.0 | 1.8 | 1x54.6 | 7 | 9.45 | 1.6 | 1x16 | 7 | 4.8 | 1.2 | 32.7 | 1004 | 3x70+54.6+2x16 | 3x70 | 12 | 10.0 | 1.8 | 1x54.6 | 7 | 9.45 | 1.6 | 2x16 | 7 | 4.8 | 1.2 | 33.8 | 1068 | 3x70+54.6+1x25 | 3x70 | 12 | 10.0 | 1.8 | 1x54.6 | 7 | 9.45 | 1.6 | 1x25 | 7 | 6.0 | 1.4 | 33.6 | 1038 | 3x70+54.6+2x25 | 3x70 | 12 | 10.0 | 1.8 | 1x54.6 | 7 | 9.45 | 1.6 | 2x25 | 7 | 6.0 | 1.4 | 35.5 | 1137 | 3x70+70 | 3x70 | 12 | 10.0 | 1.8 | 1x70 | 7 | 10.20 | 1.5 | - | - | - | - | 32.1 | 970 | 3x70+70+1x16 | 3x70 | 12 | 10.0 | 1.8 | 1x70 | 7 | 10.20 | 1.5 | 1x16 | 7 | 4.8 | 1.2 | 32.5 | 1035 | 3x70+70+2x16 | 3x70 | 12 | 10.0 | 1.8 | 1x70 | 7 | 10.20 | 1.5 | 2x16 | 7 | 4.8 | 1.2 | 33.6 | 1099 | 3x95+70 | 3x95 | 19 | 11.7 | 1.8 | 1x70 | 7 | 10.20 | 1.5 | - | - | - | - | 35.6 | 1212 | 3x95+70+1x16 | 3x95 | 19 | 11.7 | 1.8 | 1x70 | 7 | 10.20 | 1.5 | 1x16 | 7 | 4.8 | 1.2 | 35.7 | 1276 | 3x95+70+2x16 | 3x95 | 19 | 11.7 | 1.8 | 1x70 | 7 | 10.20 | 1.5 | 2x16 | 7 | 4.8 | 1.2 | 36.6 | 1340 | 3x120+70 | 3x120 | 19 | 13.0 | 1.8 | 1x70 | 7 | 10.20 | 1.5 | - | - | - | - | 38.0 | 1439 | 3x120+70+1x16 | 3x120 | 19 | 13.0 | 1.8 | 1x70 | 7 | 10.20 | 1.5 | 1x16 | 7 | 4.8 | 1.2 | 37.8 | 1503 | 3x120+70+2x16 | 3x120 | 19 | 13.0 | 1.8 | 1x70 | 7 | 10.20 | 1.5 | 2x16 | 7 | 4.8 | 1.2 | 38.6 | 1567 | 3x150+70 | 3x150 | 19 | 14.4 | 1.7 | 1x70 | 7 | 10.20 | 1.5 | - | - | - | - | 40.2 | 1650 | 3x150+70+1x16 | 3x150 | 19 | 14.4 | 1.7 | 1x70 | 7 | 10.20 | 1.5 | 1x16 | 7 | 4.8 | 1.2 | 39.8 | 1714 | 3x150+70+2x16 | 3x150 | 19 | 14.4 | 1.7 | 1x70 | 7 | 10.20 | 1.5 | 2x16 | 7 | 4.8 | 1.2 | 40.4 | 1778 | 3x120+95 | 3x120 | 19 | 13.0 | 1.8 | 1x95 | 19 | 12.50 | 1.6 | - | - | - | - | 39.5 | 1526 | 3x120+95+1x16 | 3x120 | 19 | 13.0 | 1.8 | 1x95 | 19 | 12.50 | 1.6 | 1x16 | 7 | 4.8 | 1.2 | 39.5 | 1590 | 3x120+95+2x16 | 3x120 | 19 | 13.0 | 1.8 | 1x95 | 19 | 12.50 | 1.6 | 2x16 | 7 | 4.8 | 1.2 | 39.8 | 1654 | 3x150+95 | 3x150 | 19 | 14.4 | 1.7 | 1x95 | 19 | 12.50 | 1.6 | - | - | - | - | 41.7 | 1736 | 3x150+95+1x16 | 3x150 | 19 | 14.4 | 1.7 | 1x95 | 19 | 12.50 | 1.6 | 1x16 | 7 | 4.8 | 1.2 | 41.7 | 1800 | 3x150+95+2x16 | 3x150 | 19 | 14.4 | 1.7 | 1x95 | 19 | 12.50 | 1.6 | 2x16 | 7 | 4.8 | 1.2 | 41.6 | 1865 | ABC Cable BS 7870 No. of Core & Size | Phase Core | Neutral Core | Complete Cable | No. & Section Area | No. of wire | Dia. of Conductor (Approx.) | Insulation Thickness | No. & Section Area | No. of Wire | Dia. of Conductor (Approx.) | Insulation Thickness | Overall Diameter (Approx.) | Weight (Approx.) | mm2 | mm2 | No. | mm | mm | mm2 | No. | mm | mm | mm | kg/km | 1x25 | 1x25 | 7 | 6.0 | 1.3 | - | - | - | - | 8.6 | 96 | 1x35 | 1x35 | 7 | 7.0 | 1.3 | - | - | - | - | 9.6 | 126 | 1x50 | 1x50 | 19 | 8.4 | 1.5 | - | - | - | - | 11.4 | 183 | 1x70 | 1x70 | 19 | 10.0 | 1.5 | - | - | - | - | 13.0 | 236 | 1x95 | 1x95 | 19 | 11.6 | 1.7 | - | - | - | - | 15.0 | 323 | 1x120 | 1x120 | 19 | 13.0 | 1.7 | - | - | - | - | 16.4 | 399 | 2x25 | 1x25 | 7 | 6.0 | 1.3 | 1x25 | 7 | 6.0 | 1.3 | 17.2 | 192 | 2x35 | 1x35 | 7 | 7.0 | 1.3 | 1x35 | 7 | 7.0 | 1.3 | 19.2 | 252 | 2x50 | 1x50 | 19 | 8.4 | 1.5 | 1x50 | 19 | 8.4 | 1.5 | 22.8 | 365 | 2x70 | 1x70 | 19 | 10.0 | 1.5 | 1x70 | 19 | 10.0 | 1.5 | 26.0 | 472 | 2x95 | 1x95 | 19 | 11.6 | 1.7 | 1x95 | 19 | 11.6 | 1.7 | 30.0 | 645 | 2x120 | 1x120 | 19 | 13.0 | 1.7 | 1x120 | 19 | 13.0 | 1.7 | 32.8 | 798 | 3x25 | 2x25 | 7 | 6.0 | 1.3 | 1x25 | 7 | 6.0 | 1.3 | 18.5 | 288 | 3x35 | 2x35 | 7 | 7.0 | 1.3 | 1x35 | 7 | 7.0 | 1.3 | 20.6 | 378 | 3x50 | 2x50 | 19 | 8.4 | 1.5 | 1x50 | 19 | 8.4 | 1.5 | 24.5 | 548 | 3x70 | 2x70 | 19 | 10.0 | 1.5 | 1x70 | 19 | 10.0 | 1.5 | 28.0 | 708 | 3x95 | 2x95 | 19 | 11.6 | 1.7 | 1x95 | 19 | 11.6 | 1.7 | 32.3 | 968 | 3x120 | 2x120 | 19 | 13.0 | 1.7 | 1x120 | 19 | 13.0 | 1.7 | 35.3 | 1196 | 4x25 | 3x25 | 7 | 6.0 | 1.3 | 1x25 | 7 | 6.0 | 1.3 | 20.7 | 384 | 4x35 | 3x35 | 7 | 7.0 | 1.3 | 1x35 | 7 | 7.0 | 1.3 | 23.1 | 504 | 4x50 | 3x50 | 19 | 8.4 | 1.5 | 1x50 | 19 | 8.4 | 1.5 | 27.5 | 731 | 4x70 | 3x70 | 19 | 10.0 | 1.5 | 1x70 | 19 | 10.0 | 1.5 | 31.4 | 943 | 4x95 | 3x95 | 19 | 11.6 | 1.7 | 1x95 | 19 | 11.6 | 1.7 | 36.2 | 1290 | 4x120 | 3x120 | 19 | 13.0 | 1.7 | 1x120 | 19 | 13.0 | 1.7 | 39.6 | 1595 | 5x25 | 4x25 | 7 | 6.0 | 1.3 | 1x25 | 7 | 6.0 | 1.3 | 23.2 | 480 | 5x35 | 4x35 | 7 | 7.0 | 1.3 | 1x35 | 7 | 7.0 | 1.3 | 25.9 | 630 | 5x50 | 4x50 | 19 | 8.4 | 1.5 | 1x50 | 19 | 8.4 | 1.5 | 30.8 | 914 | 5x70 | 4x70 | 19 | 10.0 | 1.5 | 1x70 | 19 | 10.0 | 1.5 | 35.1 | 1179 | 5x95 | 4x95 | 19 | 11.6 | 1.7 | 1x95 | 19 | 11.6 | 1.7 | 40.5 | 1613 | 5x120 | 4x120 | 19 | 13.0 | 1.7 | 1x120 | 19 | 13.0 | 1.7 | 44.3 | 1993 | ABC CABLE AS/NZS 3560.1 No. of Core & Size | Phase Core | Neutral Core | Complete Cable | No. & Section Area | No. of Wire | Dia. of Conductor (Approx.) | Insulation Thickness | No. & Section Area | No. of Wire | Dia. of Conductor (Approx.) | Insulation Thickness | Overall Dia. (Approx.) | Weight (Approx.) | mm2 | mm2 | No. | mm | mm | mm2 | No. | mm | mm | mm | kg/km | 2x16 | 1x16 | 7 | 4.7 | 1.3 | 1x16 | 7 | 4.7 | 1.3 | 14.6 | 132 | 4x16 | 3x16 | 7 | 4.7 | 1.3 | 1x16 | 7 | 4.7 | 1.3 | 17.6 | 263 | 2x25 | 1x25 | 7 | 6.0 | 1.3 | 1x25 | 7 | 6.0 | 1.3 | 17.2 | 189 | 3x25 | 2x25 | 7 | 6.0 | 1.3 | 1x25 | 7 | 6.0 | 1.3 | 18.5 | 283 | 4x25 | 3x25 | 7 | 6.0 | 1.3 | 1x25 | 7 | 6.0 | 1.3 | 20.8 | 378 | 2x35 | 1x35 | 7 | 7.0 | 1.3 | 1x35 | 7 | 7.0 | 1.3 | 19.2 | 249 | 3x35 | 2x35 | 7 | 7.0 | 1.3 | 1x35 | 7 | 7.0 | 1.3 | 20.7 | 373 | 4x35 | 3x35 | 7 | 7.0 | 1.3 | 1x35 | 7 | 7.0 | 1.3 | 23.2 | 497 | 2x50 | 1x50 | 7 | 8.1 | 1.5 | 1x50 | 7 | 8.1 | 1.5 | 22.2 | 334 | 3x50 | 2x50 | 7 | 8.1 | 1.5 | 1x50 | 7 | 8.1 | 1.5 | 23.9 | 501 | 4x50 | 3x50 | 7 | 8.1 | 1.5 | 1x50 | 7 | 8.1 | 1.5 | 26.8 | 668 | 4x70 | 3x70 | 19 | 10.0 | 1.5 | 1x70 | 19 | 10.0 | 1.5 | 31.4 | 933 | 2x95 | 1x95 | 19 | 11.6 | 1.7 | 1x95 | 19 | 11.6 | 1.7 | 30.0 | 638 | 4x95 | 3x95 | 19 | 11.6 | 1.7 | 1x95 | 19 | 11.6 | 1.7 | 36.2 | 1276 | 4x120 | 3x120 | 19 | 13.0 | 1.7 | 1x120 | 19 | 13.0 | 1.7 | 39.6 | 1579 | 4x150 | 3x150 | 19 | 14.6 | 1.7 | 1x150 | 19 | 14.6 | 1.7 | 43.5 | 1883 | ABC Cable GB 12527 No. of Core & Size | Phase Core | Neutral Core | Complete Cable | No. and Section Area | No. of Wire | Dia.of Conductor (Approx.) | Insulation Thickness | No. and Section Area | No. of Wire | Dia. of Conductor (Approx.) | Overall Dia. (Approx.) | Weight (Approx.) | mm2 | mm2 | No. | mm | mm | mm2 | No. | mm | mm | kg/km | 1x10 | 1x10 | 7 | 4.05 | 1.0 | - | - | - | 6.1 | 43 | 1x16 | 1x16 | 7 | 4.80 | 1.2 | - | - | - | 7.2 | 64 | 1x25 | 1x25 | 7 | 6.00 | 1.2 | - | - | - | 8.4 | 92 | 1x35 | 1x35 | 7 | 7.00 | 1.4 | - | - | - | 9.8 | 127 | 1x50 | 1x50 | 7 | 8.10 | 1.4 | - | - | - | 11.1 | 165 | 1x70 | 1x70 | 19 | 10.00 | 1.4 | - | - | - | 12.8 | 230 | 1x95 | 1x95 | 19 | 11.60 | 1.6 | - | - | - | 14.8 | 315 | 1x120 | 1x120 | 19 | 13.00 | 1.6 | - | - | - | 16.2 | 390 | 1x150 | 1x150 | 19 | 14.60 | 1.8 | - | - | - | 18.2 | 476 | 1x185 | 1x185 | 37 | 16.20 | 2.0 | - | - | - | 20.2 | 609 | 2x10 | 2x10 | 7 | 4.00 | 1.0 | - | - | - | 12.2 | 85 | 2x16 | 2x16 | 7 | 4.80 | 1.2 | - | - | - | 14.4 | 128 | 2x25 | 2x25 | 7 | 6.00 | 1.2 | - | - | - | 16.8 | 184 | 2x35 | 2x35 | 7 | 7.00 | 1.4 | - | - | - | 19.6 | 255 | 2x50 | 2x50 | 7 | 8.10 | 1.4 | - | - | - | 22.2 | 329 | 2x70 | 2x70 | 19 | 10.00 | 1.4 | - | - | - | 25.6 | 459 | 3x10 | 3x10 | 7 | 4.00 | 1.0 | - | - | - | 13.1 | 128 | 3x16 | 3x16 | 7 | 4.80 | 1.2 | - | - | - | 17.4 | 192 | 3x25 | 3x25 | 7 | 6.00 | 1.2 | - | - | - | 20.3 | 276 | 3x35 | 3x35 | 7 | 7.00 | 1.4 | - | - | - | 21.1 | 382 | 3x50 | 3x50 | 7 | 8.10 | 1.4 | - | - | - | 23.9 | 494 | 3x70 | 3x70 | 19 | 10.00 | 1.4 | - | - | - | 27.6 | 688 | 3x95 | 3x95 | 19 | 11.60 | 1.6 | - | - | - | 31.9 | 943 | 3x120 | 3x120 | 19 | 13.00 | 1.6 | - | - | - | 34.9 | 1170 | 4x10 | 4x10 | 7 | 4.00 | 1.0 | - | - | - | 14.6 | 171 | 4x16 | 4x16 | 7 | 4.80 | 1.2 | - | - | - | 17.4 | 256 | 4x25 | 4x25 | 7 | 6.00 | 1.2 | - | - | - | 20.3 | 368 | 4x35 | 4x35 | 7 | 7.00 | 1.4 | - | - | - | 23.7 | 509 | 4x50 | 4x50 | 7 | 8.10 | 1.4 | - | - | - | 26.8 | 659 | 4x70 | 4x70 | 19 | 10.00 | 1.4 | - | - | - | 30.9 | 917 | 4x95 | 4x95 | 19 | 11.60 | 1.6 | - | - | - | 35.8 | 1258 | 4x120 | 4x120 | 19 | 13.00 | 1.6 | - | - | - | 39.1 | 1559 | 1x16+16 | 1x16 | 7 | 4.80 | 1.2 | 1x16 | 7 | 5.10 | 12.3 | 108 | 1x25+25 | 1x25 | 7 | 6.00 | 1.2 | 1x25 | 7 | 6.30 | 14.7 | 158 | 1x35+35 | 1x35 | 7 | 7.00 | 1.4 | 1x35 | 7 | 7.50 | 17.3 | 221 | 1x50+50 | 1x50 | 7 | 8.40 | 1.4 | 1x50 | 7 | 9.00 | 20.1 | 300 | 2x16+16 | 2x16 | 7 | 4.80 | 1.2 | 1x16 | 7 | 5.10 | 15.5 | 172 | 2x25+25 | 2x25 | 7 | 6.00 | 1.2 | 1x25 | 7 | 6.30 | 18.1 | 250 | 2x35+35 | 2x35 | 7 | 7.00 | 1.4 | 1x35 | 7 | 7.50 | 21.1 | 348 | 2x50+50 | 2x50 | 7 | 8.30 | 1.4 | 1x50 | 7 | 9.00 | 22.4 | 464 | 3x16+16 | 3x16 | 7 | 4.80 | 1.2 | 1x16 | 7 | 5.10 | 17.4 | 235 | 3x25+25 | 3x25 | 7 | 6.00 | 1.2 | 1x25 | 7 | 6.30 | 20.3 | 342 | 3x35+35 | 3x35 | 7 | 7.00 | 1.4 | 1x35 | 7 | 7.50 | 23.7 | 475 | 3x50+50 | 3x50 | 7 | 8.10 | 1.4 | 1x50 | 7 | 9.00 | 26.8 | 629 | 3x70+70 | 3x70 | 19 | 10.00 | 1.4 | 1x70 | 19 | 10.50 | 30.9 | 869 | 3x95+95 | 3x95 | 19 | 11.60 | 1.6 | 1x95 | 19 | 12.50 | 35.7 | 1200 | 3x35+16 | 3x35 | 7 | 7.00 | 1.4 | 1x16 | 7 | 4.80 | 22.2 | 445 | 3x50+25 | 3x50 | 7 | 8.10 | 1.4 | 1x25 | 7 | 6.00 | 24.8 | 585 | 3x70+35 | 3x70 | 19 | 10.00 | 1.4 | 1x35 | 7 | 7.00 | 30.9 | 815 | 3x95+50 | 3x95 | 19 | 11.60 | 1.6 | 1x50 | 7 | 8.10 | 35.7 | 1108 | 4x95+35 | 4x95 | 19 | 11.60 | 1.6 | 1x35 | 7 | 7.00 | 39.9 | 1385 | 3x120+70 | 3x120 | 19 | 13.00 | 1.6 | 1x70 | 19 | 10.00 | 39.1 | 1399 | Cross Section of Conductor (mm2) | Min.Nos. of Wires for Conductor (mm) | Insulation Thickness (mm) | Average Max. O.D.per Single-core (mm) | Max.Conductor Resistance at 20ºC (Ω/km) | Min Insulated Resistance at Rated Working Temperature (MΩ.km) | Cable Tensile Breaking Force | 2x10 | 6 | 1.00 | 6.5x13.0 | 3.08 | 0.0067 | 0.67 | 1650 | 2x16 | 6 | 1.20 | 8.0x16.0 | 1.91 | 0.0065 | 0.65 | 2512 | 2x25 | 6 | 1.20 | 9.4x18.8 | 1.2 | 0.0054 | 0.54 | 3762 | 2x35 | 6 | 1.40 | 11.0x22.0 | 0.868 | 0.0054 | 0.54 | 5177 | 2x50 | 6 | 1.40 | 12.3x24.6 | 0.641 | 0.0046 | 0.46 | 7011 | 2x70 | 12 | 1.40 | 14.1x28.2 | 0.443 | 0.004 | 0.4 | 10354 | 2x95 | 15 | 1.60 | 16.5x33.0 | 0.32 | 0.0039 | 0.39 | 13727 | 2x120 | 15 | 1.60 | 18.1x36.2 | 0.252 | 0.0035 | 0.35 | 17339 | 2x150 | 15 | 1.80 | 20.2x40.4 | 0.206 | 0.0035 | 0.35 | 21033 | 2x185 | 30 | 2.00 | 22.5x45.0 | 0.164 | 0.0035 | 0.35 | 26732 | 2x240 | 30 | 2.20 | 25.6x51.2 | 0.125 | 0.0034 | 0.34 | 34679 | 4x10 | 6 | 1.00 | 6.5x26.0 | 3.08 | 0.0067 | 0.67 | 1650 | 4x16 | 6 | 1.20 | 8.0x32.0 | 1.91 | 0.0065 | 0.65 | 2512 | 4x25 | 6 | 1.20 | 9.4x37.6 | 1.2 | 0.0054 | 0.54 | 3762 | 4x35 | 6 | 1.40 | 11.0x44.0 | 0.868 | 0.0054 | 0.54 | 5177 | 4x50 | 6 | 1.40 | 12.3x49.2 | 0.641 | 0.0046 | 0.46 | 7011 | 4x70 | 12 | 1.40 | 14.1x56.4 | 0.443 | 0.004 | 0.4 | 10354 | 4x95 | 15 | 1.60 | 16.5x66.0 | 0.32 | 0.0039 | 0.39 | 13727 | 4x120 | 15 | 1.60 | 18.1x72.4 | 0.252 | 0.0035 | 0.35 | 17339 | 4x150 | 15 | 1.80 | 20.2x80.8 | 0.206 | 0.0035 | 0.35 | 21033 | 4x185 | 30 | 2.00 | 22.5x90.0 | 0.164 | 0.0035 | 0.35 | 26732 | 4x240 | 30 | 2.20 | 25.6x102.4 | 0.125 | 0.0034 | 0.34 | 34679 | TESTING HENAN UME CABLE CO., LTD has a strict quality control policy in every step from the order to After-sales service! Production: - Raw material inspection and test
- Production process test
- Unqualified product control
- Regular test and examination
- Finished product inspection
Certifications UME CABLE has completed several third-party product certifications to ensure our customers that all of the wire and cable purchased and installed in your projects, will fully and consistently meet all criteria of the required production and performance standards, also you are guaranteed we (as the manufacturer) and the products supplied are both valid and continuously monitored by those globally recognized quality verification system listed as below: ISO9001, ISO14001, ISO45001, CE, SGS, TUV. Packaging & Shipping Customer Visit  Company Profile  UME CABLE is one of the leading companies in the production and distribution of cables and wires in China. As a manufacturer, we have supplied quality products to more than 50 countries. Our mission is to offer our customers the best quality cable and wire products at the most competitive price, to extend and zoom the business success of our partners, to make power reach where it is needed, to optimize the running utility grids, and ultimately, to power the world. Our version is to be the most customer-centric cable and wire company with our solid technology, enthusiastic services, and robust products. UME Cable was founded in 1994, located in Zhengzhou Gongyi Huiguo Town, and occupies a total area of more than 200,000 square meters, with a building area of 20,000 square meters. The real capital assets are more than USD 6 million, with a total of 230 staff members, 35 of which are professional and technical experts. The land of our factory and employees numbers might not be the top scale of industry, but our highly automatic facilities and elite employees are the best in the industry will guarantee you a high yield rate achieved by strict cost and quality control, this is why we could quote better quality with the most competitive price within the market. FAQ Q1: Are you a manufacturer? Yes, we are the manufacturer. Q2: What are your main products? Our products range as follows: 1. Electrical wire/PVC Building Wires. 2. PVC/XLPE insulated Power Cables up to 110kv. 3. Overhead Aerial Bundle Cable/ABC Cables. 4. Bare Conductors, like AAC, AAAC, ACSR, ACAR, ASCR/AW, and so on. 5. Steel wire/strand-like EHS, GSW and ACS(Aluminum Clad Steel), CCS(Copper Clad Steel). 6. Rubber Cables, Mining Cables, Welding Cable, and Control Cables. 7. Concentric Cables with Copper/Aluminum/Aluminum Alloy 8000s' Conductor. Q3: Do you provide samples? Is it free or extra? Yes, we could offer the samples for free Q4: Is the quality of your products guaranteed? We have passed ISO9001, ISO14001, ISO45001, and all our products have CE certificates. Q5: Which markets do you involve mainly in? Our products have been exported mainly to Africa, the Middle East, Southeast Asia, South America, Central America, North America, Europe, Australia, etc. Q6: What is your payment term? T/T or L/C Q7: What about the delivery time? Generally, it is 3-7days if the goods are in stock. Or it is 7-30days if the goods are not in stock, it is according to quantity. |