Installation type | Quasi-flush |
Sensing range Sn | 2mm |
Detected object | Magnetic metal |
Standard detection object(iron) | 12x12x1mm |
Set distance | 0-1.6mm |
Tolerance distance | Detection distance below 10% |
Response frequency | 800Hz |
Working voltage | 10-30VDC |
Leakage current | <0.8mA |
Max. load current | 200mA |
Voltage drop | <1V |
LED display | Red |
Protection circuit | Surge protection circuit,short circuit protection,polarity reversal
protection |
Ambient temperature | During operation:-25 to+70°C(no freezing,no condensing) |
Ambient humidity | During operation and shorage: 35-95%RH(no condensing) |
Effect of temperature | Temperature range-25 to 70°C,with a detection distance within ±10%
for every 20°C change |
Effect of voltage | When the rated power supply voltage fluctuates within ±15%,the
detection distance changes within ±1% |
Insulation resistance | >50MΩ |
Withstand voltage | AC1000V |
Vibration resistance | 10 to 55 Hz, up and down amplitude 1.5 mm in the X, Y, and Z
directions for each 2 hours |
Impact resistance | 500m/S ², 10 times in each direction of X, Y and Z |
Connection type | M12 Connector |
Sensing surface meterial | PBT |
Protection grade | IP67 |