Disposable SMS Sterile/Non sterile Surgical Gown Usage Surgical Gown can be used during the surgery operations. They
are used to reduce risk of infection and create a layer of
protection against splash for surgeons in all kinds of operations.
Critical parts are reinforced with an extra layer. Precautions in use- The sterile surgical gown should be kept flat and free from leaks or stains. If there are
leaks, stains, etc., it can not be used.
- Before use, check that the packaging is intact, sealed, air-tight,
and able to withstand normal transportation and storage, and
confirm the effective shelf life of the product to ensure that it
is used within the effective time.
- The sterile surgical gown is placed in an environment without
corrosive gas, with low relative humidity, suitable temperature and
good ventilation.
-
Testing Items | Unit | Average | Max/Min | Judge | Test method | Basic weight | g/㎡ | 35 | Max | 36 | pass | ASTM D3776 | Min | 34 | Tensile strength | MD | N | 62 | > | 61 | pass | ASTM D5034 | CD | N | 42 | > | 42 | pass | Hydro | cm | 41 | > | 40 | pass | AATCC 127 | Attribute& Visual Defect | Properties | Quality requirements(English) | | Surface/ Package | No obvious uneven ,no noticeable crease ,no broken edge, consistent
rolls | pass | Contami nation | No obvious contamination defect including metal ,oil, grease, powder, or strange material | pass | Polymer drop | No obvious contamination defect including metal ,oil, grease, powder, or strange material | pass | Holes/Tears/Cuts | No holes/tears/cuts | pass | Width/e nd/volume | Flat end face | pass | Split joint | No linker (the roll that the length is insufficient. It ’ s no more
than 10% every lot, as s result of uncontrolled reasons) | pass |