SHT2000 LED Digital Humidity Controller Hygrometer Power Switch CE Certified Monitor
|
Detailed Product Description
Digital Temperature Humidity Controller SHT2000 LED Thermoregulator Thermostat Humidistat Hygrometer SwitchDescription:Setting method: Start value Setting method: Start value > stop
value (the program automatically determines the working mode is
cooling/dehumidifying mode) Heating/cooling mode setting Setting mode: setting (starting temperature): Press and hold the button to start the temperature flashing. Use key to set the starting temperature value. Setting (stop temperature): Press and hold the button to stop the temperature flashing. Use to set the stop temperature value. Heating use case: control the water heater, heat to 65 ° C to stop, the temperature
drops back to 50 ° C and start heating again The first step: heating mode, starting temperature Step 2: Press and hold the button to start the temperature
flashing. Use to set the starting temperature to 50 °C. Step 3: Press and hold the button to stop the temperature flashing. Set the stop temperature to 65 °C with keys, and the setting is completed! Refrigeration use case: use in the farm, the fan is ventilated to 26 ° C to stop, the temperature is raised to 30 ° C and the ventilation is started again. The first step: cooling mode, starting temperature > stop temperature Step 2: Press and hold the button to start the temperature flashing. Use to set the starting temperature to 30 °C. The third step: long press the button to stop the temperature flashing, set the stop temperature to 26 °C by , the setting is completed! Humidification/Dehumidification Mode Settings: Setting (start humidity): Press and hold key to start the humidity value flashing. Set the humidity value by key. Set [Stop Humidity]: Press and hold key to stop the humidity value flashing, and set the humidity to stop by key value. Humidification example: fresh supermarket humidification, control humidifier 50% RH began to humidify, humidified to 80% RH to stop humidification. Setup steps: Step 1: Press and hold the button for 3 seconds to start the humidity value flashing, and set the starting humidity value to 50% RH. Step 2: Press and hold the button for 3 seconds to stop the humidity value flashing. Set the value to 80% RH. After the setting is completed, the button will be operated for 5 seconds without returning to the normal display state. Dehumidification example: workshop control exhaust dehumidification system, humidity 70% RH starts dehumidification, humidity 40% RH stops dehumidification Setup steps: Step 1: Press and hold the button for 3 seconds to start the humidity value flashing, and set the starting humidity value to 40%RH. Step 2: Press and hold the button for 3 seconds to stop the humidity value flashing, set the value to 70% RH, the setting is completed, the button does not operate for 5 seconds, and automatically returns to the normal display state. |
| Product Tags: SHT2000 humidity controller CE certified digital hygrometer power switch monitor LED humidity controller monitor |
Related Products
|
Indoor Digital Humidity Controller Temperature Meter CE Certified Environmental Monitor |
|
W2023 Wall-Mounted Intelligent Electronic Humidity Control Switch 110V-220V Digital Regulator |
|
10A LCD Display Digital Humidity Controller NTC Sensor AC 110V-220V Monitoring Regulator |
|
SHT2000 LED Digital Humidity Controller Hygrometer Power Switch CE Certified Monitor |
|
SHT20 10A DC 6V-30V High-Precision Digital Humidity Controller Temperature Monitoring Sensor |
|
NTC Sensor 10A Digital LCD Humidity Controller Temperature Meter Monitoring Device |
Email to this supplier