AAS-2630 Double Beam Atomic Absorption Spectrophotometer Automatic
|
>AAS-2630 Atomic Absorption SpectrophotometerFeatures Using PC for automatic controlling & data processing; Integrated design of the flame atomizer and the graphite furnace atomizer, both of which can be automatically switched; Eight lamps automatic switch, automatically adjust supply and optimization of the beam position, pre-set optimization hollow cathode lamp working conditions for multi elemental detection convenient Automatic ignition, automatic flow rate setting, turn off automatic protection, automatically adjusts negative high voltage, lamp current; Automatic control wavelength scanning, automatic peak search completed within 30 seconds, Auto-zero, the gas flow is set automatically Advanced and reliable the safety protection system, full range of safety protection for the operator Hydride generator for option The excellent quality of the optical system, optical system suspension design, the vibration and the environmental temperature changes can not affect the instrument performance Convenient and reliable utility software assistant, comprehensive support the windows platform The new design of the flame atomizer and high sensitivity of the graphite furnace.
Performance Index >1. >Optical system Wavelength: 190nm-900nm Monochromator: C-T, aberration Wavelength accuracy: ±0.15nm Wavelength repeatability: <0.10nm Baseline shift: 0.004A/30min Detector: high sensitivity photomultiplier Spectrum bandwidth: 0.1nm, 0.2nm, 0.4nm, 1.0nm, 2.0nm for option Dispersion element: plane diffraction grating, 1800article/nm, scoring area 40x40mm2 Resolution ratio: in 0,2nm spectral bandwidth, the half width of the measuring spectral line no more than0.2nm±0.02nm
>2. >Atomic system (Cu) characteristic concentration: 3.0μg/ml, absorbance not less than 0.300Abs (Cu) detection limit: <0.005μg/ml Precision: RSD≤0.8% Sprayer: high efficiency glass atomizer Burner: 100mm titanium metal, air premixed Atomizing chamber: corrosion resistant material Position adjustment: auto setting for the optimum height of the flame burner and front and rear position Safety: with many kinds of automatic protection
>3. >Graphite furnace atomic system (Cd) characteristic concentration: 0.5x10-12g, (Cd) detection limit: 3.0μg/ml, 15μL sample, absorbance not less than 0.31Abs Precision: RSD≤0.3% Heating temperature range: -3000℃ in room Heating rate: >2000℃ Temperature control accuracy: ≤1% Heating temperature control method: the power control method of the dry ashing stage, the atomization stage with the maximum power control Heating condition setting: up to 11 programs, ramp heating-up, moment heating-up, maximum power heating-up Safety: with the alarm and automatic protection when cooling water flow in lack, superheat and over current indicting by the argon under voltage Background correction: in 1A deuterium background correction ≥30 times, in 1A self absorption background correction≥60 times Graphite furnace heating method: constant power heating Measurement method: air-acetylene flame method, hydride generator atomic absorption method, graphite furnace method Concentration calculation: standard curve method (1-3 times curve), interpolation method, standard addition method Repetition survey frequency: 1-20times, calculate average value, display standard deviation and relative standard deviation Printing result: parameters print, data result print, graph print, summary report Software: Windows 98/2000/XP Data output: instantaneous value, integral value, peak value, peak area
>4. >Automation system Eight lamps automatic switch, with the high-performance lamps Auto scanning and peaking of the wavelength, auto transfer the slit Auto setting the gas flow, to choose the best combustion ratio Auto setting for the optimum height of the flame burner and front and rear position Automatic alarm in fray-out of the flame, alarm in ignition failure Water seal position confirmation protection
>5. >Instrument parameter AAS Voltage: AC 220V/50HZ Power: 220VA Weight: 100Kg Volume: 1170mm (L)×480mm(W)×440mm(H)
>6. >Graphite furnace Voltage: AC 380V/50HZ Power: 12KVA Weight: 450Kg Volume: 410mm (L)×480mm(W)×440mm(H) Operating temperature: 10℃~35℃ Operating humidity: ≤80%
>7. >Standard Layout Main host Low noise oil free air compressor Operating software Accessories Wooden case packaging and transportation |
| Product Tags: Double Beam Atomic Absorption Spectrophotometer Automatic Atomic Absorption Spectrometer AAS-2630 Spectrophotometer with warranty |
|
AAS-320N Double Beam Atomic Absorption Spectrophotometer |
|
AAS-7000 Series AAS Atomic Absorption Spectrophotometer |
|
AAS-4510 AAS Atomic Absorption Spectrophotometer 190nm - 900nm |
|
Lab Automatic AAS Atomic Absorption Spectroscopy Absorption Spectrophotometer |
|
AAS-361 Series Atomic Absorption Spectroscopy Instrument |
|
AAS-2630 Double Beam Atomic Absorption Spectrophotometer Automatic |