1000L Climate Chamber CMS-1000A with lighting Features: - Utilizes a PID temperature control system supporting programmable
operation modes.
- Features a large LCD touch screen that displays all operating
parameters in real-time.
- Dual air circulation system combining forced convection with
vertical diffusion.
- High-quality antibacterial stainless steel chamber with rounded
corners for easy cleaning.
- Three-sided lighting system with 5 adjustable intensity levels,
accurately simulating natural day-night cycles.
- Independent drainage pipes prevent chamber debris from
contaminating the humidification water source.
- Automatic defrosting function prevents temperature and humidity
drift caused by evaporator frosting.
- Detachable protective cover for temperature and humidity sensors
prevents failure from poor contact.
- Equipped with universal dual-wheel casters with brakes for safe and
convenient mobility.
- Unique air duct structure resistant to high and low temperatures,
paired with a specialized fan.
- External RS485 communication interface enables remote PC control
and monitoring.
- Comprehensive safety protections: leakage protection, independently
adjustable temperature safety device.
- Water shortage/overflow protection, compressor overvoltage
protection, cooling fan overheating protection.
- Triple alarm system for door opening, power failure, and sensor
failure.
- Core components include German compressors and Swiss Rotronic
humidity sensors.
- Optional infrared CO2 concentration monitoring and control system.
Specifications | Model | CMS-300A | CMS-450A | CMS-800A | CMS-1000A | | CMS-300B | CMS-450B | CMS-800B | CMS-1000B | | Convection Mode | Forced convection | | Control Mode | Balance | | Temperature Resolution | 0.1℃ | | Temperature Control Range | With illumination: 10℃~65℃ Without illumination: 0℃~65℃/±0.1℃ | | Humidity Control Range | <20~95%RH/±1.5%RH | | Illumination | 0~25000LX,5-grade adjustment(Optional: 0-30000LX) | | Working Temperature | 5℃~30℃ | | Programme Control | Programmable LCD with touch screen | | Overall Dimensions(W*D*H,mm) | 800*910*1610 | 790*990*1860 | 1200*1100*1900 | 1540*1100*1900 | | Chamber Dimensions(W*D*H,mm) | 600*565*900 | 605*650*1150 | 1020*700*1150 | 1280*700*1150 | | Volume | 305L | 452L | 822L | 1030L | | Refrigerant | R134a | | Rated Power | 2200W | 2450WV | 3100W | 3500W | | Water Tank Capacity | 20L | | Power Supply | AC-220V,50/60HZ | | Safety Protection | Compressor over pressure protection, over heat protection,current
leakage progection, over load, under pressure, water shortage
protction | | Shelf Qty. | 3 | | Notes: Humidity control,water tank and water pipes are not
available for CMS-300A/450A/800A/100A |
Introduction about incubator The reliability of any scientific instrument hinges on rigorous
calibration and maintenance, and laboratory incubators are
paramount in this regard. Given their role in sustaining sensitive
biological processes, even minor deviations in temperature,
humidity, or CO2 can compromise months of research. Regular
calibration against NIST-traceable standards is non-optional.
Temperature uniformity mapping, often performed annually, ensures
every shelf location within the chamber meets the setpoint,
critical for multi-rack experiments. CO2 sensors, whether thermal
conductivity (TC) or infrared (IR), require routine calibration
with certified gas mixtures; IR sensors generally offer greater
stability and resistance to humidity fluctuations. Humidity
control, often managed via a passive water pan or active steam
generator, needs monitoring to prevent under-humidification
(causing media desiccation) or over-humidification (risking
condensation and contamination). Preventive maintenance includes cleaning and decontamination
protocols, often using hydrogen peroxide vapor or specialized
disinfectants, coupled with replacing HEPA filters to ensure clean
airflow. Modern units feature data logging and alarm systems that
document conditions and alert researchers to deviations, a feature
essential for Good Laboratory Practice (GLP) and regulatory
compliance in pharmaceutical or clinical work. Thus, a
well-maintained incubator is not just a box that provides heat; it
is a validated, traceable component of the research infrastructure,
directly safeguarding data integrity and reproducibility.
|