ATV12 Frequency Converter Inverter Specialized frequency converter for mechanical equipment 0.18-4 KW
|
Detailed Product Description
|
ATV12 Frequency Converter Inverter Specialized frequency converter
for mechanical equipment 0.18-4 KW Specialized frequency converter for mechanical equipment 0.18-4 KW
featuring easy installation, compact design, and integrated
multiple functions. The optional base-mounted version makes it
particularly suitable for simple industrial machinery or various
civil equipment. Core Electrical Parameters
Key Advantages
Typical Applicable Scenarios Thanks to its compact and flexible design, the series covers
multiple industrial and civil fields. Commercial Equipment
Small Industrial Machinery
Other Applications
Model Specifications 100 - 120V Single-Phase Specifications Models in this voltage range have a power focus of 0.18 - 0.75kW,
suitable for low-voltage small civil or simple commercial
equipment.
200 - 240V Single-Phase Specifications This range covers a power output of 0.18 - 2.2kW, suitable for most
commercial equipment and small civil machinery.
200 - 240V Three-Phase Specifications Covering a power range of 0.18 - 4kW, this range is the mainstream
choice for small industrial machinery.
Frequently Asked Questions Overcurrent Alarm (displays "oCF") and Tripping Immediately After
Startup This is a high-frequency issue when the inverter is used with
kneaders and small conveyors in food processing plants. Inspection
may reveal motor cable insulation damage or sudden heavy material
loading causing current surge. To troubleshoot: check for cable
damage, manually rotate the motor shaft to check for jams, and
appropriately extend the acceleration time parameter. Displays "PRA" Lock and Inverter Is Completely Unresponsive This often occurs with Altivar 12 inverters paired with access
control devices and small labeling machines. Usually caused by
ignoring the requirement to short the +24V terminal and PWR
terminal during on-site wiring. Use a multimeter to measure if
there is a stable 24V voltage between +24V and 0V. If normal, short
the two terminals to unlock. Frequent Shutdown Due to Poor Heat Dissipation and Abnormally Hot
Housing This is particularly common in dusty environments. The inverter's
cooling fan is prone to clogging with dust. Normally, the
inverter's operating temperature inside the distribution cabinet
should be 30 - 50℃. To resolve: regularly clean the heat sink with
compressed air (at least once a year) and avoid blocking the
inverter's heat dissipation channels. Displays "CFF" Configuration Error and Fails to Operate Normally This often happens after equipment maintenance, accessory
replacement, or reprogramming. Usually due to a mismatch between
replaced accessories and the inverter's power specifications. To
fix: enter the "fcs" option in the "conf" menu to reset parameters
to factory defaults, then reconfigure programming parameters
according to the motor nameplate. Displays "OPF1" Phase Loss Fault and Abnormal Motor Operation This mostly occurs with three-phase motor-compatible Altivar 12
models. Triggered when the inverter detects excessively low current
or an open circuit in one phase of the motor circuit. To
troubleshoot: retighten the wiring terminals, use a clamp meter to
check if the current in each phase is balanced, and inspect for
motor line damage. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Product Tags: ATV12 frequency converter for machinery 0.18-4KW mechanical equipment inverter specialized frequency converter with warranty |
Related Products
|
22kW Variable Frequency Drive Inverter ACS355 Three Phase Frequency Converter |
|
I510 Cabinet Frequency Converter Inverter 0.25kW-15kW Frequency Drive Inverter |
|
ATV310 Ac Frequency Converter 0.37kW-30kW VFD Inverter 3 Phase |
|
NE200/NE300 AC Frequency Converter VFD Inverter Drive 0.4KW-900KW |
|
FR-E800 Networked Vector Frequency Converter 0.4-22kW VFD Single Phase To Three Phase |
|
M701 High Performance Inverter 200V-690V Rock Solid In Harsh Environments |
Email to this supplier