ES700 Series Elevator-specific Frequency Inverter and Converter
|
Detailed Product Description
|
ES700 Series Elevator-specific Frequency Inverter and Converter Elevator-specific functions for comfort and peace of mind. This
dedicated inverter drives induction motors and PM motors with high
performance, incorporating Yaskawa's core attributes of
versatility, ease of use, and reliability, along with all
specialized functions required for elevator drive systems. Core Performance Parameters
Motor Compatibility Parameters
Safety Specification Parameters
Power Supply Compatibility Parameters
Structure & Design Parameters
Function Configuration Parameters
Available Models
Application Areas Residential Elevator Scenarios Suitable for low-rise (3-10 floors), mid-rise (10-30 floors),
high-rise (30-50 floors) and super high-rise (above 50 floors)
residential elevators, including ordinary commercial housing,
high-end residences and villa elevators.
Commercial Building Elevator Scenarios Covers passenger elevators, escalator supporting drives (partially
adapting to escalator frequency conversion needs) and cargo
elevators in commercial venues such as office buildings, shopping
malls, hotels and exhibition centers.
Special Elevator Scenarios Includes hospital-specific elevators (stretcher elevators),
industrial plant cargo elevators, warehouse heavy-load elevators,
small service elevators and barrier-free elevators.
Supplementary Sub-scenarios
Frequently Asked Questions Q: The elevator occasionally has a "jerking feeling" when starting
or stopping, instead of smooth acceleration/deceleration. What's
the reason? A: It's most likely that the acceleration/deceleration time or
S-curve characteristic parameters are not properly adjusted,
leading to poor matching with the elevator load. It could also be
due to improper setting of feedforward control parameters, causing
delayed speed response. You can first readjust the
acceleration/deceleration curve according to the elevator's common
load range, then calibrate the feedforward control gain. Q: The inverter displays an "overcurrent" fault. It can temporarily
recover after a restart but occurs frequently. How to troubleshoot? A: First, check if the motor wiring is loose or oxidized,
especially if the contacts of the star-connection contactor are
ablated (focus on PM motor models). Then confirm if the motor
insulation is aging or if the load is overweight (e.g., the
elevator runs at full load for a long time). If both are normal,
the inverter's internal current detection module may be faulty and
require inspection and repair. Q: After retrofitting an old elevator, the "anti-slip-down
function" occasionally triggers falsely, causing the elevator to
stall at startup. How to solve this? A: The brake of an old elevator may be severely worn, leading to
delayed brake feedback signals and the inverter misjudging it as
"slipping." You can first adjust the sensitivity threshold of the
anti-slip-down function and extend the signal detection time. At
the same time, check the brake wear and replace the brake pads or
adjust the brake clearance if necessary. Q: The PM motor model makes more noise during operation than the
induction motor model, and torque ripple is noticeable. Is this
normal? A: No, it's not normal. It's most likely that the motor
self-learning was not properly performed, and the inverter failed
to accurately match the PM motor parameters (such as magnetic pole
position and stator resistance). It could also be that the torque
compensation parameter is set too high. You can re-run the
elevator-specific self-learning (even with steel cables attached)
and then reduce the torque compensation gain to optimize operation
smoothness. Q: When using UPS for rescue operation after a power outage, the
inverter occasionally fails to start or shuts down immediately
after starting. What's the problem? A: First, confirm if the UPS voltage is within the compatible range
(200V class: 48VDC~340VDC; 400V class: 48VDC~680VDC). Low voltage
will trigger protection. Then check if the UPS capacity is
sufficient, especially when the elevator load is
large--small-capacity UPS may not be able to drive it. In addition,
if the control power supply is not separated from the main circuit
power supply (without the optional part), it may also cause
unstable power supply and trigger shutdown. Q: After the inverter has been running for several years, it shows
an "overheating" alarm, especially in summer. How to handle this? A: First, clean the dust on the inverter's cooling fan and heat
sink (elevator machine rooms usually have a lot of dust, which can
easily block them) and check if the fan speed has decreased or if
it has stopped. Then confirm if the machine room ventilation is
good and if the ambient temperature exceeds the inverter's
operating range. If it's a heavy-load condition, the 50% ED rated
load may not be properly matched, and long-term overload operation
can cause overheating. You need to adjust the operating load or
replace it with a larger capacity model. Q: Encoder-related alarms occur frequently, such as "encoder signal
loss." The wiring is checked and normal. What's the reason? A: The encoder itself may be aging (e.g., the battery of the
absolute encoder is dead) or the connection between the encoder and
the motor shaft is loose. It could also be a fault in the
inverter's encoder signal interface module. You can first replace
the encoder battery (if replaceable) and re-fix the connecting
shaft. If the error still occurs, use a multimeter to detect the
voltage and waveform of the signal interface to determine if it's
an internal inverter fault. Q: The CANopen-Lift protocol fails to connect to the elevator main
control board. The parameters are set correctly, but communication
still fails. How to troubleshoot? A: First, confirm if the protocol has been activated (some models
require separate activation for the protocol, which is not enabled
by default). Then check if the shield layer of the communication
cable is properly grounded to avoid electromagnetic interference
(wiring in elevator machine rooms is complex and prone to
interference). In addition, the protocol version of the main
control board must match the inverter--for example, models with
under-development DCP3/DCP4 protocols cannot be connected to
old-version main control boards. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Product Tags: ES700 elevator frequency inverter elevator-specific converter with warranty frequency inverter for elevator systems |
Related Products
|
22kW Variable Frequency Drive Inverter ACS355 Three Phase Frequency Converter |
|
I510 Cabinet Frequency Converter Inverter 0.25kW-15kW Frequency Drive Inverter |
|
ATV310 Ac Frequency Converter 0.37kW-30kW VFD Inverter 3 Phase |
|
NE200/NE300 AC Frequency Converter VFD Inverter Drive 0.4KW-900KW |
|
FR-E800 Networked Vector Frequency Converter 0.4-22kW VFD Single Phase To Three Phase |
|
M701 High Performance Inverter 200V-690V Rock Solid In Harsh Environments |
Email to this supplier