Fixed TDLAS Remote Methane Natural Gas Smell Detector Landfill Biogas Digester

Brand Name AiLF
Model Number P20
Certification ATEX
Place of Origin Shandong,China
Minimum Order Quantity 1
Price $32000~$40000
Payment Terms T/T
Supply Ability 200 Units Per Month
Delivery Time 7-10 Work Days
Packaging Details 45*33*28cm 8.2kg
Product Name Pan tilt On Site Laser Methane Leak Monitoring
Target Gas Methane (CH4)
Detection Method Laser Absorption Spectrum
Concentration Range 0-50,000 ppm • m
Detection Limit 5 ppm • m
Operating Temperature -10°C to 70°C
Operating Humidity 0% to 98% RH (Non-condensing)
Weight Around 5.5kg
Response Time 0.05S
Dimension 139mm x 139mm x 263mm
Power Consumption 20W
Enclouse Protection Class IP68
Usage Gas Storage Station
Detailed Product Description

Landfill Biogas Digester Fixed TDLAS Laser Methane Leakage Inspection Monitoring

 

 

Description:

The P20 Pan Tilt laser gas leak monitoring system is an advanced laser methane detector for pipelines,Landfill, Biogas Digester and gas storage facilities. The Remote laser methane leak monitoring systems work according to the TDLAS principle (Tunable Diode Laser Absorption Spectroscopy) for the detection of methane. This laser method has the advantage that it is very sensitive at the specific measuring wavelength of methane (λ = 1.65 μm) and has no relevant cross-sensitivities to other gases in the atmosphere, e.g. exhaust gases from other cars.

 

P20 Pan Tilt Gas Leak Monitoring System is a 24/7 of solutions for automated continuous gas leak detection. P20 Gas Leak monitoring are designed to operate 24/7 in oil & gas locations. They are configured for continuous monitoring for Methane gas leaks, and to automatically alert, quantify and report leaks to the control room through a dedicated software system. 


How Pan Tilt P20 open path works:
The laser emits a narrow beam of light at a wavelength that matches the absorption profile of the target gas. As the beam passes through the gas, some of the light is absorbed by its molecules. A receiver then captures the reflected light, and by analyzing how much was absorbed, the system determines the gas concentration. It's designed for continuous monitoring of infrastructure like gas pipelines and can be programmed to scan specific routes.
 


Features:

Fully automatic: Pan Tilt P20 Open-Path operates autonomously and does not require a separate power source.

Fast detection: Detects gas leaks faster than conventional methods. Detection time 0.1 sec.

Non-stop operation: Pan Tilt P20 Open-Path works 24 hours a day all year round.

Sensitive to methane only: The Pan Tilt P20 open path laser monitoring is precisely calibrated to detect methane and ignores other gases, providing accurate readings without false alarms.

Network monitoring: Pan Tilt P20 Open-Path can be integrated into a mesh network with centralized control, allowing the operator to receive real-time data from all connected devices.

Dust and rain protection: Pan Tilt P20 Open-Path meets the IP66 protection standard and safe from harsh weather conditions like rain, snow, or sandstorms.

Receiver and transmitter self-test mode: To ensure accurate methane detection.

High sensitivity: Pan Tilt P20 Open-Path determines the leakage of any mixture in which 1% methane is present.

Various useful features: Availability of heated optics, non-volatile memory, real time clock, auto-zero and built-in signal processing algorithm
 
 Technical Parameters:
 

Model

P20

Detection Subject

Methane(CH4)

Measuring Principle

TDLAS

Detection Lase「Class

Class I Eye safe

Resolution

3 ppm·m

Indication Laser Class

Class IIIR No Direct Sight or Instrument Observation

Response Time

0.05s

Explosion-proof Grade

ATEX Exib 11B T4 Gb

Concentration Range

0 ~ 50,000 ppm·m

Enclosure Protection Class

IP68

Maximum Detection Distance

150m

Operating Temperature

-40 ~ 70 ℃

Pan-tilt Control

Azimuth 360 °&Elevation +/-90 °

Operating Humidity

< 90%RH, no condensation

Power Consumption

20W

Main Unit Dimension

139x 139 x 263mm

Main Housing Material

Stainless Steel

Weight

5.5 kg


Multi Application:
P20 's ultra-low power consumption supports solar power supply and can be connected to the backend system via 5G network. Its compact size and weight, similar to a surveillance camera, make it easier to install and dismantle.
 


Pan Tilt Scanning Natural gas leak monitoring systems are used in various industries, including:

Oil and Gas: 
Monitoring pipelines, storage facilities, and processing plants for leaks. 

Manufacturing: 
Detecting leaks in industrial processes involving flammable or toxic gases.
 
Energy: 
Monitoring gas distribution networks and power plants. 

Chemical: 
Detecting leaks in chemical plants and storage facilities. 

Wastewater Treatment:
Detecting leaks in biogas systems and other processes involving potentially hazardous gases. 
 

 

 

 