PRODUCT DESCRIPTION
It is suitable for overhead power lines with AC rated voltage of
35kV andbelow. It is used in cities and towns, high-rise buildings,
forest areas and otherplaces with high safety requirements.
Usage features:
- Rated voltage: 1 kV and 10 kV.
- Operating temperature: For PVC and polyethylene insulation, the
temperature shall not exceed 70 °C; for cross-linked polyethylene
insulation, the temperature shall not exceed 90 °C, with a
short-circuit duration not exceeding 5 seconds. Maximum temperature
of cable conductors: 160°C for PVC insulation, 150°C for
polyethylene insulation, and 250°C for cross-linked polyethylene
insulation; the cable laying temperature must not be lower than
-20°C.
Cable Specifications
| Size/mm² | Conductor Diameter mm | Insulation Diameter mm | Outer Diameter mm |
| 2X0.2 | 11/0.15 (BC) | 1.4±0.05 | 4.5±0.1 |
| 2X0.3 | 16/0.15 (BC) | 1.6±0.05 | 4.6±0.5 |
| 2X0.5 | 16/0.20 (BC) | 1.9±0.05 | 5.5±0.1 |
| 2X0.75 | 24/0.20 (BC) | 2.2±0.05 | 6.2±0.1 |
| 2X1.0 | 32/0.20 (BC) | 2.5±0.05 | 7.0±0.1 |
| 2X1.5 | 48/0.20 (BC) | 2.9±0.05 | 7.8±0.1 |
| 2X2.5 | 80/0.20 (BC) | 3.6±0.05 | 9.6±0.1 |
| 2X4.0 | 80/0.25 (BC) | 4.2±0.05 | 11.0±0.1 |
| 3X0.2 | 11/0.15 (BC) | 1.4±0.05 | 5.0±0.1 |
| 3X0.3 | 16/0.15 (BC) | 1.6±0.05 | 5.4±0.5 |
| 3X0.5 | 16/0.20 (BC) | 1.9±0.05 | 6.2±0.1 |
| 3X0.75 | 24/0.20 (BC) | 2.2±0.05 | 7.2±0.1 |
| 3X1.0 | 32/0.20 (BC) | 2.5±0.05 | 7.6±0.1 |
| 3X1.5 | 48/0.20 (BC) | 2.9±0.05 | 8.7±0.1 |
| 3X2.5 | 80/0.20 (BC) | 3.6±0.05 | 10.4±0.1 |
| 3X4.0 | 80/0.25 (BC) | 4.2±0.05 | 12.1±0.1 |
| 4X0.2 | 11/0.15 (BC) | 1.4±0.05 | 5.4±0.1 |
Applications:
Control cables (typically rated at 450/750 V or below) are
primarily used to transmit control commands, measurement signals
and status feedback; they do not carry high-power electrical
energy. They are widely used across industries such as
manufacturing, energy, construction, transport and specialised
environments.
I. Industrial Automation (Core Sector)
Smart Manufacturing: Connections between PLCs, variable frequency
drives, sensors, actuators and robots; interlocking of equipment on
automotive and electronics assembly lines, speed regulation and
workstation signal exchange.
Process Industries: DCS systems in the petroleum, chemical,
metallurgical and building materials sectors; valve control and
temperature, pressure and flow signal feedback; flame-retardant and
armoured cables designed for high-temperature and explosion-proof
environments.
Machinery and Equipment: Control circuits and emergency
stop/interlock signal transmission for CNC machine tools, cranes,
textile machinery and packaging machinery.
II. Energy and Power
Power Stations / Substations: Connection of high-voltage switches,
current transformers, relay protection and control panels; circuit
breaker operation, unit monitoring, and transmission of automated
telecontrol signals.
Power Distribution Systems: Signal transmission for smart
distribution cabinets, ring main units, electricity meters and
terminal controls.
III. Construction and Buildings
Building Automation (BA): Centralised control and interlocking of
HVAC (air conditioning/ventilation), lighting, water supply and
drainage, and lifts/escalators.
Fire Protection Systems: Control and interlocking of fire alarms,
sprinkler pumps, smoke extraction fans and emergency lighting
(commonly using fire-resistant, low-smoke, halogen-free types).
Security and Low-Voltage Systems: Signal and control connections
for CCTV cameras, access control, alarm control panels and car park
systems.
IV. Transport
Rail Transport: Control of metro/high-speed rail carriages (doors,
lighting, air conditioning), signalling systems, traction control
and connections to on-board equipment.
Marine/Offshore Engineering: Engine room control, navigation, power
monitoring, deck machinery; Oil-resistant, waterproof,
flame-retardant, marine-grade cables.
Airports / Ports: Control of baggage sorting systems, boarding
bridges, loading/unloading equipment, signal lights and navigation
facilities.
V. Specialised and Public Facilities
Water Treatment / Environmental Protection: Connection of pumps and
valves, chemical dosing systems, monitoring instruments and PLCs in
sewage and water treatment plants; waterproof, corrosion-resistant,
armoured cables.
Mining / Tunnels: Underground control, ventilation, drainage,
lighting; explosion-proof, flame-retardant, high-tensile, armoured
cables.
Medical / Laboratories: CT, MRI, precision instrument control and
operator panel signals; high-shielding, low-interference,
medical-grade cables.
FAQ
Q1: What is the primary purpose of control cables? How do they
differ from power cables?
A1: Their primary purpose is to transmit control commands,
measurement signals and status feedback; they are not designed to
carry high-power electrical energy. The key difference between
control cables and power cables is that power cables are designed
to transmit electrical energy (such as in power supply lines),
whereas control cables are designed for signal transmission (such
as equipment interlocking commands). Control cables typically have
a rated voltage of 450/750 V or lower and are available in smaller
gauges.
Q2: How can one quickly select the appropriate control cable type
for different applications?
A2: Select based on application priority: KVV for general indoor
use; KVVP/KYJYP (shielded types) for environments with high levels
of interference (e.g. frequency converters, precision instruments);
KVVR/KVVRP (flexible types) for mobile or drag-chain applications
(e.g. machine tools, production lines); For fire
safety/environmental protection applications, use WDZ-KYY
(low-smoke, halogen-free, flame-retardant) or fire-resistant types;
for special environments (explosion-proof, waterproof,
corrosion-resistant), use the corresponding specialised armoured or
special-purpose types.
Q3: What does the rated voltage of 450/750V for control cables
mean?
A3: 450V is the rated voltage between conductors, whilst 750V is
the rated voltage between a conductor and earth. This voltage
rating meets the control signal transmission requirements for the
vast majority of industrial, construction and transport sectors,
and is suitable for low-voltage equipment control circuits.
Q4: What is the purpose of shielded control cables (such as KVVP)?
In which scenarios are they mandatory?
A4: Their purpose is to resist external electromagnetic
interference and prevent signal distortion (such as accidental
equipment triggering or signal interruption). Mandatory
applications include: smart manufacturing (PLCs, variable frequency
drives and associated equipment), security surveillance, precision
instruments (medical and laboratory equipment), and rail signalling
systems – all scenarios where high signal stability is required.
Q5: What is the difference between flexible control cables (KVVR)
and standard control cables (KVV)?
A5: The key differences lie in flexibility and intended
applications: KVV cables are designed for fixed installation, offer
moderate flexibility, and are suitable for indoor fixed wiring
(such as inside distribution boards or within walls); KVVR is a
flexible type, with conductors typically consisting of multiple
strands of fine copper wire twisted together; it is bendable and
resistant to dragging, making it suitable for mobile equipment
(such as cranes, drag-chain machine tools, and interlinked sections
of production lines).
Q6: Why are low-smoke, halogen-free, flame-retardant or
fire-resistant types prioritised for control cables used in fire
protection systems?
A6: Fire safety scenarios are high-risk environments. Low-smoke,
halogen-free, flame-retardant types (such as WDZ-KYY) produce
minimal smoke and no toxic gases when burning, thereby reducing the
risk of personnel poisoning and obstruction of visibility;
fire-resistant types can maintain power supply and signal
transmission for a certain period during a fire, ensuring the
normal operation of fire safety equipment (such as sprinkler pumps,
smoke extraction fans and alarm systems), and buying time for
evacuation and rescue.
Q7: What specific requirements must control cables meet for special
environments such as ships and mines?
A7: For ships and offshore engineering, cables must be
oil-resistant, waterproof, flame-retardant and hold marine-grade
certification to withstand seawater corrosion and engine room oil
contamination. For mines and tunnels, cables must be
explosion-proof, flame-retardant, high-tensile and armoured to suit
the damp, dusty and impact-prone conditions underground, thereby
preventing safety incidents caused by cable damage.