Max. current ±100mA
Weight 500g
Size 15 x 9 x 3 cm
Communication USB / Bluetooth
Potential control range ±10V
EIS YES,10μHz ~ 1MHz
Current range: 200pA~200mA, 10 ranges
Potential range ±200mV ±2V, ±5V, ±10V
Potential accuracy 0.1%× full range
Minimum potential resolution 1μV
Minimum current resolution 1pA
Power supply USB / built-in Li-ion battery 10AH@3.7V
Detailed Product Description

The CS100ME handheld potentiostat supports full electrochemical methods, including potentiostatic/galvanostatic polarization curve, Cyclic voltammetry analysis, impedance(EIS), and galvanic current measurement. etc. It has built-in chargeable li-ion battery and Bluetooth communication. The device supports laptop/computer software or mobile APP. It can be used for electrochemical tests in field or special non-electricity environment. CS100ME can be a convenient handheld tool for researchers of energy& materials, environment protection, biosensor, foods &drugs, corrosion protection etc. Maximum current is ±100mA

The voltage control range is ±10V, compliance voltage is ±10V, the maximum current output is ±100mA, and the minimum current resolution can reach 1pA. The EIS frequency range is 10μHz~1MHz.

 

Thanks to its small size with comprehensive electrochemical functions, it’s typically used for:

- Battery materials’ performance test in a glove box

- Ultra-low detection limit of heavy metal ions for water quality test in environmental protection field

- Low current detection in biosensor thanks to high current accuracy

- Effective ingredients detection in food and drug industry

- Outdoor bridge corrosion and soil corrosion measurements

 

Note: maximum current during experiment doesn’t exceed ±45mA then the handheld potentiostat can be used. If exceeds ±45mA an ordinary size potentiostat with maximum current ±2A should be considered.

 

Features

- Small & light, handheld and convenient

- Easy to install and use

- High accuracy, current resolution can reach to 1pA, and measurement accuracy is 0.1% of the range.

-during outdoor test, a laptop’s USB port can be used for both charging and communicating

- The circuit adopts floating design. Electrochemical parameters of the grounded system can be measured without an isolation transformer.

 

 

Specifications of the portable potentiostat

Size / weight:15 x 9 x 3 (cm), 500g

Communication: USB / Bluetooth

Power supply: USB / built-in Li-ion battery 10AH@3.7V

Support 2-, 3-or 4-electrode system

Maximum current: ± 100mA

Potential control range: ±10V

EIS frequency range: 10μHz ~ 1MHz

Compliance voltage: ±10V

Current range: 200pA~200mA, 10 ranges

Potential range:±200mV ±2V, ±5V, ±10V

Potential accuracy: 0.1%× full range

Minimum potential resolution: 1mV

Current accuracy: 0.1%× full range

Minimum current resolution: 1pA

Reference electrode input impedance: 1013Ω||8pF

AC amplitude: 0~±2.5V

Signal response bandwidth: 1MHz

Max. acquisition rate: 150,000 data points/s

CV and LSV scan rate: 0.001mV~ 10V/s

 

Electrochemical techniques- handheld potentiostat CS100ME

Stable polarization

  • Open Circuit Potential (OCP)
  • Potentiostatic (I-T curve)
  • Galvanostatic
  • Potentiodynamic (Tafel plot)
  • Galvanodynamic (DGP)

Transient Polarization

  • Multi Potential Steps
  • Multi Current Steps
  • Potential Stair-Step (VSTEP)
  • Galvanic Stair-Step (ISTEP)

Chrono Method

  • Chronopotentiometry (CP)
  • Chronoamperametry (CA)
  • Chronocaulometry (CC)

Voltammetry

  • Linear Sweep Voltammetry (LSV)
  • Cylic Voltammetry (CV)
  • Staircase Voltammetry (SCV) #
  • Square Wave Voltammetry (SWV) #
  • Differential Pulse Voltammetry (DPV) #
  • Normal Pulse Voltammetry (NPV)#
  • Differential Normal Pulse Voltammetry (DNPV) #
  • AC Voltammetry (ACV)
  • 2nd harmonic AC Voltammetry (SHACV)
  • Fourier Transform AC Voltammetry (FTACV)

# there is correspinding Stripping Voltammetry

Electrochemical Impedance Spectroscopy (EIS)

  • Potentiostatic EIS (Nyquist, Bode)
  • Galvanostatic EIS
  • Potentiostatic EIS (Optional freq.)
  • Galvanostatic EIS(Optional freq.)
  • Mott-Schottky
  • Potentiostatic EIS vs. Time (Single freq.)
  • Galvanostatic EIS vs. Time (Single freq.)

Corrosion Measurements

  • Potentiodynamic (Tafel plot)
  • Cyclic polarization curve (CPP)
  • Linear polarization curve (LPR)
  • Electrochemical Potentiokinetic Reactivation (EPR)
  • Electrochemical Noise (EN)
  • Zero resistance Ammeter (ZRA)

Battery test

  • Battery Charge and Discharge
  • Galvanostatic Charge and Discharge (GCD)
  • Potentiostatic Charging and Discharging(PCD)
  • Potentiostatic Intermittent Titration Technique(PITT)
  • Galvanostatic Intermittent Titration Technique(GITT)

 

Product Tags: 45mA Portable Handheld Potentiostat   Handheld Potentiostat Galvanostat   Portable Potentiostat Galvanostat  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: Wuhan Corrtest Instruments Corp., Ltd.
Subject:
Message:
Characters Remaining: (80/3000)