System | System structure | 1 control cabinet + 2 aging cabinets + 1 water temperature cabinet |
Overall size | 6900*1600*2050mm |
Total floor area | 6900*2500mm(Including operation area) |
Total input voltage | Three-phase five-wire system 220Vac (rated) |
Total input current | 250A |
Total input power | 150kW |
Application ambient temperature | 0-40℃ |
Application environment humidity | 0-95% |
Fire protection requirements | Materials meet UL 94V0 rating |
Environmental requirements | Materials comply with Rohs, WEEE requirements |
Safety requirements | Comply with IEC62368 international standard design requirements |
Burn-in cabinet | Burn-in bits/cabinet | 16 bits/cabinet |
Burn-in bits/layer | 4 bits/layer |
Burn-in product power | 20kW/bit |
Burn-in product input voltage | 150-1000Vdc |
Burn-in product input current | 50A/bit |
Burn-in Product Load Category | Inductive/Motor/AC Feedback Load |
Burn-in product load current | 350A (inductor/motor)/40A (AC feedback load) |
Auxiliary voltage of Burn-in products | 8-30Vdc |
Auxiliary current of Burn-in products | 10A |
Power Connector Type | SB50 (HV+/HV-) |
Load Connector Type | SB350 (U/V/W/PE) |
Signal Connector Type | 24Pin 5566 |
Input power | 320kW |
Feedback power | 256kW |
Constant temperature range | Room temperature+5°C-60°C |
Constant temperature accuracy | ±5°C |
Number of temperature control points | 5 |
Open type | Sliding door/folding door/side door |
Volume size | 2100*1600*2050mm |
Dimensions in the product area | 1700*550*1500mm |
Product area layers | 4 |
Bit space size | 425*550*350mm |
Minimum floor height | 300mm |
Top floor height | 1450mm |
Product area air duct direction | Left and right ventilation |
Cooling method | Air cooling |
Material | 1.5mm cold rolled sheet |
Water temperature cabinet | Water temperature range | Room temperature+5°C-60°C |
Water temperature accuracy | ±5°C |
Water temperature | 8 |
Number of serial products/way | 4/way |
Dissipated power/circuit | 4kW/way |
Cooling method | Chilled water or air cooling |
Water pressure range | 0.05-0.2MPa |
Flow range | 3-15L/min |
Channel diameter | 3/4 inch |
Volume size | 880*1000*1900mm |
Monitoring software | Display running information | Input voltage, current, power, output voltage (DC source module communication or product communication) |
Show status information | Not Connected / Vacant / Passed / Under Voltage / Under Current /
Over Voltage / Over Current / No Output / Protection |
Display accuracy | ±(1%+0.2%FS) |
Control precision | ±(1%+0.2%FS) |
Bad way of reporting | Audible alarm |
Report format | CSV format |
Statistics | Yield/CPK/Time Distribution |
MES docking | Support |
Scan speed | 5S |
Control cabinet | Control system | Window 10 |
Display medium | Computers and Monitors |
Manipulating medium | Mouse and keyboard |
Communication method | Cable |
Type of protection | Over current, leakage, over temperature, smoke, emergency stop |
Alarm method | Sound and light alarm, remote network |
Heat dissipation type | Air cooling |
Maintenance mode | Post maintenance |
Material | 1.5mm cold rolled sheet |
Volume size | 880*860*1900mm |