System | System structure | 1 control cabinet + 2 burn-in cabinets |
Overall size | 5100*1500*2050mm |
Total floor area | 5100*2500mm(Including operation area) |
Total input voltage | Three-phase five-wire system 220Vac (rated) |
Total input current | 300A |
Total input power | 160kW |
Application ambient temperature | 0-40℃ |
Application environment humidity | 0-95% |
Burn-in cabinet | Burn-in bits/cabinet | 9 bits/cabinet |
Burn-in bits/layer | 3 bits/layer |
Burn-in product power | 40kW/bit |
Burn-in product input voltage | 200-1000Vdc/bit |
Burn-in product input current | 100A/bit |
Burn-in Product Load Category | 35kW/bit |
Burn-in product output voltage | Three-phase five-wire |
Burn-in product output current | 80A/bit |
Bit Status Indicator | No |
Input power | 380kW |
Feedback power | 315kW |
Constant temperature range | Room temperature+5°C-60°C |
Constant temperature accuracy | ±5°C |
Number of temperature control points | 5 |
Open type | Sliding door/folding door/side door |
Bit space size | 560*550*480mm |
Minimum floor height | 300mm |
Top floor height | 1320mm |
Product area air duct direction | Left and right ventilation |
Cooling method | Air cooling |
Material | 1.5mm cold rolled sheet |
Monitoring software | Display running information | Input voltage, current, power, output voltage (DC source module communication or product communication) |
Show status information | Not Connected / Vacant / Passed / Under Voltage / Under Current /
Over Voltage / Over Current /No Output / Protection |
Display accuracy | ±(1%+0.2%FS) |
Control precision | ±(1%+0.2%FS) |
Bad way of reporting | Audible alarm |
Scan speed | 5S |