I. Core Parameters of Sintering Furnace Temperature Performance • Rated Temperature: 1300°C (standard operating range) • Maximum Temperature: 1500°C (short-term limit; material tolerance
must be considered) • Usage Tip: Evaluate the lifespan of sintering plates and
refractory materials when exceeding 1300°C.
Furnace Structure • Effective Dimensions: 400×330×800mm (W×H×D), suitable for small
to medium-sized workpieces. • Sintering Plate: Made of corundum mullite, offering
high-temperature resistance and chemical stability. • Refractory Materials: ◦ Inner Layer: Polycrystalline mullite (high insulation, thermal
shock resistance) ◦ Outer Layer: Ceramic fiberboard (lightweight insulation,
significant energy savings). Monitoring & Expandability • Pre-installed thermocouple ports and temperature monitoring holes
support multi-point measurement or upgrades. Exterior & Color • Dimensions: 850×900×1200mm, light gray casing (standard
industrial color).
II. Temperature Control Cabinet Configuration Temperature Control Channels • 5+2 channel design: 5 channels directly connected to the furnace,
2 channels reserved (flexible expansion/redundancy). • Instrument Count: 7 temperature controllers (independent control
per channel for precision). Control Instruments • Models: Eurotherm 3504 or Japanese imports (international brands,
high reliability). • Key Features: ◦ PID auto-tuning (automatically optimizes heating curves) ◦ High-temperature alarms, thermocouple failure alerts
(comprehensive safety) ◦ Power/voltage modulation (precise adjustments to minimize
fluctuations). Over-Temperature Protection • Dual safeguards: audible/visual alarms + heating cutoff to
prevent equipment/workpiece damage. Exterior & Color • Dimensions: 800×1850×500mm (vertical design, space-saving) • Color: Light gray (matches the furnace).
| Item | pecifications | Quantity | Notes | | Kiln Main Unit | Primary heating system | 1 set | Core equipment for thermal process | | Setter Plate | Material: Corundum-Mullite | 1 set | High-temperature resistant carrier |
- The equipment must be installed indoors, with an ambient
temperature range of -10℃ to 45℃. The indoor environment must be
free of flammable gases, corrosive gases, and vapors.
- The equipment requires a floor space of no less than 4 square
meters, with a working area length of at least 2 meters, width of
at least 2 meters, and height of no less than 3 meters. The
foundation must be sturdy and level, and the furnace weighs
approximately 400kg.
- The power supply for this furnace must be a three-phase five-wire
AC power line, with a voltage of 380±10% V and a frequency of 50±2%
Hz. This power line is dedicated, and high-power conversion
equipment such as welding machines, electric furnaces, and
metal-cutting machine tools should not be connected to this
distribution.
- The equipment must be reliably grounded.
|