Brand Name 3051S high-precision pressure transmitter
Model Number 3051S
Certification IS9001
Place of Origin Singapore
Minimum Order Quantity 1pcs
Price negotiable
Payment Terms T/T,L/C
Delivery Time 8 work days
Packaging Details carton
Accuracy ±0.04% of span
Communication Protocol HART, FOUNDATION Fieldbus, Profibus PA, 1-5 VDC HART Low Power, WirelessHART
Measurement Type Pressure
Process Connection 1/4-18 NPT male
Ambient Temperature -40 to 185°F (-40 to 85°C)
Mounting Type Integral or remote mount
Display LCD with backlight
Wetted Materials 316L SST, Alloy C-276, Alloy 400, Tantalum, Gold-plated Alloy 400
Protection Rating IP67
Measurement Range 0-10,000 psi
Output Signal 4-20 mA with digital signal based on HART protocol
Power Supply 10.5-55 VDC
Process Temperature -40 to 185°F (-40 to 85°C)
Certifications ATEX, FM, CSA, IECEx, INMETRO, NEPSI, EAC, KOSHA, RCM, CRN, CE, PED, SIL
Detailed Product Description

3051S Pressure Transmitter



Product Description:


The Rosemount 3051S Pressure Transmitter is a high-performance device engineered for ultra-precise measurement of pressure, flow, and level across demanding industrial applications. Built on the SuperModule™ platform, it features industry-leading accuracy (up to ±0.025% of span), long-term stability, and robust overpressure protection. Its scalable design supports various configurations—including Coplanar™, In-line, and Multivariable models—and advanced digital protocols like HART®, WirelessHART®, and FOUNDATION™ Fieldbus. With SIL 2/3 safety certification and compatibility with Electronic Remote Sensor (ERS™) systems, it offers both versatility and peace of mind for process control, energy flow, and level monitoring tasks.


Specifications:


Feature / Model3051S (Scalable Performance)3051CD (Coplanar Differential)3051HT (Hygienic Transmitter)
Accuracy±0.025% of span (best-in-class)±0.04% of span±0.1% of span
Stability15-year stability10-year stability5-year stability
Measurement TypeDifferential, Gauge, Absolute, MultivariableDifferential PressureGauge/Absolute Pressure (Hygienic)
Design PlatformSuperModule™ (hermetic, all-welded)Coplanar™Sanitary design with 3-A and EHEDG compliance
Turn Down RatioUp to 200:1Up to 100:1Up to 20:1
Process ConnectionsCoplanar, In-line, Remote Seal, ERS™CoplanarTri-Clamp®, DIN 11851, Varivent®
CertificationsSIL 2/3, NACE, CSA, ATEX, IECExSIL 2/3, CSA, ATEX3-A, EHEDG, FDA, CIP/SIP compliant
Communication ProtocolsHART®, WirelessHART®, FOUNDATION™ FieldbusHART®, WirelessHART®, FOUNDATION™ FieldbusHART®, FOUNDATION™ Fieldbus
Typical ApplicationsHigh-accuracy flow, level, and pressure controlGeneral-purpose DP flow and levelFood, beverage, pharmaceutical pressure monitoring
Cost$$$ (Premium)$$ (Mid-range)$$ (Mid-range, sanitary-specific)


Summary:

  1. Choose 3051S when you need maximum accuracy, diagnostics, and scalability.
  2. Choose 3051CD for reliable differential pressure in standard industrial setups.
  3. Choose 3051HT for sanitary applications requiring hygienic design and compliance.

Key Features:

  1. Ultra-stable performance: Offers up to ±0.025% reference accuracy and 15-year stability.
  2. Wide range down: 200:1 turndown for broad application flexibility.
  3. Multiple outputs: Supports 4–20 mA HART®, WirelessHART®, and FOUNDATION™ Fieldbus.
  4. Robust construction: Available in materials like 316L SST, Alloy C-276, and Tantalum for harsh environments.
  5. Diagnostics: Includes Plugged Impulse Line detection and loop integrity checks.
  6. Safety certified: SIL 2/3 certified for use in safety instrumented systems.


Applications:


Rosemount 3051S Pressure Transmitter – FAQ

1. What types of pressure does the 3051S measure?

It supports differential, gauge, absolute, and multivariable pressure measurements.

2. What is the accuracy of the 3051S?

It offers up to ±0.025% of span, making it one of the most accurate transmitters in its class.

3. What is the long-term stability?

The 3051S provides 15-year stability, reducing recalibration needs and maintenance costs.

4. What communication protocols are supported?

It supports 4–20 mA HART®, WirelessHART®, and FOUNDATION™ Fieldbus.

5. Is it suitable for safety applications?

Yes, it is SIL 2/3 certified per IEC 61508 for use in safety instrumented systems.

6. What mounting options are available?

It comes in Coplanar™, In-line, and Remote Seal configurations, including ERS™ (Electronic Remote Sensor) systems.

7. Can it be used for flow and level measurement?

Absolutely. When paired with primary elements (like orifice plates or Annubars), it enables accurate flow and level measurement.

8. What materials are available for wetted parts?

Options include 316L SST, Alloy C-276, Tantalum, and others for corrosive environments.

9. What is the turn-down ratio?

It supports a 200:1 range down, offering wide application flexibility.

10. Is it compatible with wireless systems?

Yes, the WirelessHART® version enables remote monitoring with high reliability and low installation cost.

Product Tags: Foundation Fieldbus Protocol Pressure Transmitter   3051S Pressure Transmitter   Process Temperature Pressure Transmitter  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: Shaanxi Huibo Electromechanical Technology Co., Ltd
Subject:
Message:
Characters Remaining: (80/3000)