LCD Display 3051CD HART Pressure Transmitter for Precise Pressure Monitoring

Model Number 3051CD
Certification IS9001
Place of Origin Singapore
Minimum Order Quantity 1pcs
Price negotiable
Payment Terms T/T
Delivery Time 5-8 work days
Packaging Details carton
Communication Protocol HART
Measurement Range 0-1000 psi
Housing Material Aluminum
Accuracy +/- 0.075% of span
Display LCD
Protection Rating IP67
Weight 2.5 lbs
Power Supply 10.5-55 VDC
Process Connection 1/4-18 NPT
Output Signal 4-20 mA
Mounting Direct mount or remote mount
Wetted Materials 316L stainless steel
Operating Temperature -40 to 85 degrees Celsius
Detailed Product Description

3051CD Hart Pressure Transmitter

Introduction:

The Rosemount 3051CD is a high-performance differential pressure transmitter designed for precise measurement and long-term reliability in industrial applications. With advanced HART® digital communication, exceptional accuracy (±0.04% of span), and robust diagnostics, it supports critical operations in flow, level, and pressure monitoring. Its Coplanar™ platform simplifies installation, while optional Bluetooth® and WirelessHART® capabilities enhance remote configurability and operational efficiency.

Technical Parameters: 

Feature / Model3051CD (Differential)3051CG (Gauge)3051CA (Absolute)3051S (SuperModule)
Measurement TypeDifferential PressureGauge PressureAbsolute PressureAll types (DP, GP, AP)
Reference Accuracy±0.04% of span±0.04% of span±0.04% of span±0.025% of span
Stability (10 years)±0.2% of URL±0.2% of URL±0.2% of URL±0.125% of URL
Rangeability (Turndown)Up to 150:1Up to 150:1Up to 150:1Up to 200:1
Output Protocols4–20 mA HART, Wireless4–20 mA HART4–20 mA HARTHART, FOUNDATION Fieldbus, Wireless
Coplanar™ Platform
Bluetooth® Option
DiagnosticsLoop Integrity, Plugged LineSameSameAdvanced + Power Advisory
Display OptionGraphical LCD (M6)SameSameEnhanced LCD
SIL CertificationSIL 2/3SIL 2/3SIL 2/3SIL 2/3
Best Use CasesFlow, Level, Filter MonitoringTank Pressure, Pump ControlVacuum Systems, ReactorsHigh-accuracy critical apps

Selection Tips

  1. Choose 3051CD for low differential pressure applications like filter monitoring or flow across orifice plates.
  2. Use 3051CG when measuring gauge pressure in tanks or pipelines.
  3. Opt for 3051CA for absolute pressure in vacuum or sealed systems.
  4. Select 3051S when ultra-high accuracy, diagnostics, or scalability are critical.
5Coplanar electroplated carbon steel SST electroplated carbon steel------
2Coplanar SST SST SST------
3(2)Coplanar Hastelloy C Hastelloy C Hastelloy C------
4Coplanar Monel Monel Monel------
8(2)Coplanar electroplated carbon steel, Hastelloy C, electroplated carbon steel------
7(2)Coplanar SST Hastelloy C SST------
0Alternative flange - see options H2H3H4H7F1F2G1G2FAFBFCFD or S5


codeIsolation DiaphragmCD CG CA
5316L SST------
2Hastelloy C-276------
3(2)Monel ------
4Tantalum (only applicable to 3051CD and CG models, range 2-5. Not applicable to 3051CA model)------
5Gilded Monel------
6



code0-type ringCD CGCA
AGlass-filled tetrafluoroethylene (TFE)------
BGraphite-filled tetrafluoroethylene (TFE)------
codeFill liquidCD CGCA
1silicone oil------
2Inert liquid (halogenated hydrocarbon)------
codeShell material, conduit inlet sizeCDCGCA
AAluminum, coated with polyurethane coating 1/2-14NPT------
BAluminum, coated with polyurethane M2x1.5 (CM20)------
CAluminum, coated with polyurethane PG13.5------
DAluminum, coated with polyurethane G 1/2------
JSST 1/2-14NPT------
KSST M2x1.5 (CM20)------
LSST PG13.5------

Rosemount 3051CD HART Pressure Transmitter – FAQ

1. What does the model “3051CD” signify?

The “C” denotes the Coplanar™ design, while “D” indicates Differential Pressure measurement capability.

2. How accurate is the 3051CD?

It offers exceptional accuracy of ±0.04% of span, with long-term stability of ±0.2% URL over 10 years.

3. Which communication protocols are available?

Standard output is 4–20 mA with HART®. Optional WirelessHART® and Bluetooth® configurations are also available for enhanced flexibility.

4. Can it be used for flow and level applications?

Absolutely. Paired with primary flow elements or installed on pressurized tanks, it provides dependable flow and level monitoring.

5. What pressure ranges are supported?

Multiple range codes are available, from ±3 inH₂O to ±2000 psi, covering low differential to high static pressure needs.

6. What’s the best mounting position for low-pressure applications?

For optimal accuracy in draft ranges, mount the unit with isolators parallel to the ground.

7. What kind of diagnostics are included?

Built-in Loop Integrity and Plugged Impulse Line Detection help identify installation issues and maintain uptime.

8. Is the 3051CD certified for safety systems?

Yes, it is SIL 2/3 certified, meeting the requirements for Safety Instrumented Systems (SIS).

9. What is the weight of the transmitter?

Approximately 5.7 lbs (2.6 kg), excluding optional mounting assemblies or accessories.

10. What materials are used for wetted components?

Options include 316L Stainless Steel, Alloy C-276, Tantalum, and others to ensure compatibility with demanding process fluids.