Customized Duct Fire Damper Automatic For Smoke Ventilation Ductwork
|
Detailed Product Description
|
Customized Fire Damper System for Smoke Exhaust / Ventilation
Product Description
1. Ventilation and air conditioning systems: Fire dampers are often
used in ventilation ducts or air conditioning systems. When a fire occurs in the duct, the fire damper can prevent the
fire from spreading and adjust the airflow to ensure the safety of
personnel during evacuation. 2. Stairwells and fire escapes: In these evacuation passages, the
setting of fire dampers can effectively prevent smoke from entering
the passages, ensuring that personnel can evacuate successfully in
a shorter time. 3. Mechanical pressurized air supply system: For spaces such as
smoke-proof stairwells and refuges that need to prevent smoke from
intruding, setting fire dampers can prevent smoke from entering. 4. Cable shafts and pipe shafts: Fire dampers in these shafts can
prevent fires from spreading to other floors through electrical
lines or cable fires. 5. Fire dampers are also required in places where high temperatures
may occur, such as kitchens and bathrooms, to ensure that the fire
can be effectively controlled when a fire occurs. Benefits
1. Smoke exhaust valve: The smoke exhaust valve is installed on the
pipes of the smoke exhaust system of high-rise buildings and
underground buildings. Its basic functions are: temperature (smoke) electrical signal
linkage, smoke exhaust fan starts at the same time; manually open the valve, the smoke exhaust fan starts at the same
time; output valve opening signal. 2. Smoke exhaust fire damper: The smoke exhaust fire damper is
installed on the smoke exhaust system pipes that meet the
requirements of smoke exhaust and fire prevention (installed on the
pipe at the suction port of the smoke exhaust fan). In addition to the functions of the smoke exhaust valve, its basic
functions also have the function of melting when the exhaust
temperature exceeds 280℃, closing the valve and stopping the smoke
exhaust fan at the same time.3. Fire-proof regulating valve: The fire-proof regulating valve is
installed on the ventilation and air-conditioning system pipeline
with fire-proof requirements (to prevent the fire from spreading
along the air duct). Its function s include: the temperature fuse melts at 70℃ to close the valve; output valve closing signal, the ventilation and air-conditioning
system fan stops; stepless air volume adjustment. 4. Smoke and fire-proof regulating valve: The smoke and fire-proof
regulating valve is installed on the ventilation and
air-conditioning system pipeline with smoke and fire-proof
requirements (to prevent the spread of smoke and fire). Its functions include: the smoke (temperature) electrical signal
linkage makes the valve close, the ventilation and air-conditioning
system fan stops; the valve is closed manually, and the fan stops; the temperature fuse melts at 70℃ to close the valve; output valve closing signal; step-by-step air volume adjustment according to 90° five equal
divisions.
Specifications
Feature
Flue gas baffle door is used in the inlet, outlet or bypass flue
gas desulfurization and denitration system. -in plate is usually driven by electric hydraulic drive to expand
and expand to isolate the flue gas. Can be opened or closed by DCS near and far operation.
|
||||||||||||||||||||||||
| Product Tags: Customized duct fire damper Customized fire and smoke dampers duct fire damper For Smoke Ventilation |