High Accuracy Digital Total Chlorine Sensor RS485 4-20mA Output
|
Total Chlorine Digital Sensor RS485 4-20mA output
>>Overview Total chlorine refers to chlorine present in the form of free chlorine or combined chlorine (referring to chlorine existing as chloramine and organic chloramine forms) or a combination of both, i.e., the sum of combined chlorine and free chlorine, also known as total residual chlorine. When chlorine is added to water, it undergoes a series of chemical reactions that vary depending on water quality characteristics. When ammonia nitrogen exists in water, HOCl reacts with ammonia to form compounds called amines (commonly known as chloramines). Residual chlorine electrodes primarily measure HOCl. In regions with high ammonia nitrogen content in water, where disinfection mainly relies on chloramines, total residual chlorine testing is typically required. This sensor employs a three-electrode system with a specialized membrane structure that enhances mechanical stress resistance and chemical tolerance while remaining unaffected by pH levels. It is suitable for various water treatment applications, including seawater, brine (15% NaCl), and water environments containing surfactants. The electrode outputs 4-20mA/RS485/0~±2V standard signals that can directly connect to secondary instruments, PLCs, RTUs, and other intelligent terminal devices.
>>Feature ▪ Utilizes a membrane method to accelerate response time and ensure
stable signals.
>>Technical Parameter Measurement Variable: Total Chlorine Calibration Method: Zero-point drift-free; Single-point slope calibration based on chemical method pH Range: 4.0–12.0 Operating Temperature: 0–45°C Maximum Pressure: 2.0 bar Flow Rate: 15–30 L/h (in flow cell) Response Time: Initial polarization time: ~2 hours; T90 response time: 2 minutes Drift: ≤ -1% per month in drinking water at 25°C, pH 7.2 Supply Voltage: 9–36 VDC Output Signal: Two-wire 4-20mA; RS485; 0~±2V; Built-in temperature compensation Maintenance Cycle: Membrane cap lifespan: 1 year; Electrolyte replacement interval: 1 year |
Product Tags: Total Chlorine Sensor 4-20mA output High accuracy Total Chlorine Sensor |
![]() |
Digital Residual Chlorine Dissolved Ozone Chlorine Dioxide Sensor 9-36VDC |
![]() |
Digital Disinfection Sensor RS485 Membrane Method Residual FCL Sensor |
![]() |
High Accuracy Digital Total Chlorine Sensor RS485 4-20mA Output |
![]() |
Digital RS485 4-20mA Residual Chlorine Sensor Membrane Method |
![]() |
Membrane Method Residual Chlorine Sensor FCL Chlorine Dioxide Sensor NPT3/4 Thread |
![]() |
Constant Voltage Residual Chlorine Probe Chlorine Dioxide Ozone Sensor For Swimming Pool Drinking Water |