Technical parameter:
No. | Specification | IG541(52% nitrogen;40% argon,8carbon dioxide) |
1 | Capacity | 80Ltr | 90ltr |
2 | Working Pressure | 15MPa | 20MPa | 20MPa | 30MPa |
3 | Device Model | QMH15/80 | QMH20/80 | QMH20/90 | QMH30/90 |
4 | Model Number | QM H20/90-XL-010 |
5 | Discharge Time | ≤60S |
6 | Driving Bottle Group Pressure | 6MPa |
7 | Maximum Working Pressure at 50℃ | 211.15kg/M³/281.06kg/M³ |
8 | Fire Extinguishing Method | Full Flooding |
9 | Activation Method | Automatic, Pneumatic, Manual, Mechanical Emergency Operation |
10 | Applications | Financial Center Archives Room |
Description:
IG541 Inert Gas Fire Suppression System is a cutting-edge solution
designed to safeguard financial archives from fire hazards while
preserving both paper records and digital storage media. Comprising
52% nitrogen, 40% argon, and 8% carbon dioxide sourced from natural
atmospheric components, the system extinguishes fires by reducing
oxygen concentration to 12%-15% through physical displacement.
Unlike traditional water-based or chemical systems, it leaves no
residue and poses zero risk of corrosion or moisture damage, making
it ideal for protecting sensitive financial documents, server
racks, and magnetic storage devices.
Inert Gas Fire Suppression System based on IG541 is a cutting-edge
solution designed specifically for environments where protection of
both paper records and digital storage systems is critical.
Composed of 52% nitrogen, 40% argon, and 8% carbon dioxide, this
system operates by reducing the oxygen level within a protected
area to a point where combustion cannot be sustained, typically
below 15%, while maintaining a breathable atmosphere for occupants.
The Inert Gas Fire Suppression System offers unparalleled safety
for sensitive assets because it leaves no residue, does not conduct
electricity, and is environmentally friendly with zero ozone
depletion potential (ODP) and global warming potential (GWP). This
makes it an ideal choice for financial institutions that require
fire suppression without risking damage to valuable documents or
electronic equipment.
Application:
Financial institutions face unique challenges in protecting decades
of paper records and mission-critical digital assets. The IG541
Inert Gas Fire Suppression System addresses these needs through
tailored engineering and compliance with industry standards:
1. Paper & Digital Asset Protection
Financial archives contain irreplaceable documents (e.g.,
contracts, share certificates) and servers storing client data. The
system’s non-conductive, residue-free operation prevents damage to
both paper (avoiding ink smudging/fiber degradation) and digital
equipment (protecting hard drives/SSDs from short circuits). A 2023
case study at UBS Zurich demonstrated the system’s ability to
suppress a simulated electrical fire in 45 seconds, with zero data
loss and minimal document degradation—outperforming water-based
systems by 80% in asset preservation.
2. Compliance with Data Regulations
Strict regulations like GDPR and FINRA Rule 4511 mandate data
integrity in financial archives. The system’s zero-chemical
footprint ensures compliance with these standards, as no residues
interfere with forensic audits or digital recovery processes. At
Morgan Stanley’s New York archive facility, the system enabled
seamless adherence to SEC 17a-4(f) requirements for fire safety,
avoiding $2.1 million in potential fines.
3. Space Optimization in Compact Archives
Financial archives often feature dense shelving and raised-floor
server rooms. The system’s lightweight aluminum piping reduces
structural load by 30% compared to steel alternatives, while its
50cm clearance requirement enables installation in narrow aisles. A
Deutsche Bank project in Frankfurt utilized this design to protect
12,000㎡ of archives without expanding existing footprint, saving
€1.8 million in renovation costs.
4. Rapid Response for Time-Sensitive Data
Financial markets operate on millisecond precision, and downtime
can result in millions in losses. The system’s 60-second discharge
time minimizes heat exposure to servers, with a 2024 Goldman Sachs
test showing a 92% faster cooling rate compared to CO₂ systems. Its
8% CO₂ concentration also supports safe evacuation by stimulating
deep breathing, ensuring personnel can retrieve critical documents
before exiting.
5. Long-Term Cost Efficiency
Traditional systems require frequent recharging and space-intensive
storage for chemicals. The IG541 system’s 30-year lifespan and
low-pressure maintenance (annual checks vs. monthly for Halon
alternatives) reduce total ownership costs by 45%. A Lloyds Banking
Group analysis revealed a 15-year ROI of 220%, driven by avoided
document restoration expenses and compliance penalties.
Company profile:
Guangzhou Xinlin Fire Fighting Equipment Co., Ltd., established in
2017 with a registered capital of RMB 10 million, is a leading
provider of advanced fire safety solutions headquartered in
Dongzhou Industrial Park, Xintang Town, Zengcheng District,
Guangzhou. Committed to innovation and reliability, the company
specializes in state-of-the-art clean gas automatic fire
extinguishing systems, including FM200(HFC-227ea),Novec1230,IG541
and IG100 systems, complemented by sophisticated gas fire alarm
control panels.These products are widely adopted across diverse
sectors, such as municipal infrastructure, power plants,
telecommunications, healthcare facilities, and construction
projects, thanks to their efficiency, safety, and environmental
sustainability.
Supported by over 30 patents and a team with more than eight years
of collective expertise in fire protection engineering, Xinlin Fire
offers comprehensive services spanning system design, engineering,
and seamless project execution. Operating from a modern 2398 -
square - meter facility, Xinlin Fire integrates automated
production lines and cutting - edge testing equipment to ensure
consistent, high - quality output.
The company's production system has passed the dual certifications
of the internationally authoritative SGS factory inspection
certification and the German TÜV Rheinland factory inspection. At the same time, it has obtained ISO
9001 (Quality Management System), ISO 14001 (Environmental
Management System), and ISO 45001 (Occupational Health and Safety
Management System). Ensure that every link of the product from
production to delivery complies with international standards. In
addition, we also provide Chemical Data Sheets (MSDS) to
comprehensively ensure the compliance and safety of product
transportation, storage and use. Choosing us means choosing
professionalism and trust.
Frequently Asked Questions:
Q1: Are you a manufacturer or a trading company?
A1: We are a professional manufacturer specializing in gas fire
suppression systems.
Q2: Can you give me a sample order?
A2: Yes, of course you can. We welcome you to order samples to test
and check the product quality. Provide mixed samples.
Q3: Do you offer OEM products?
A3: Yes, we welcome your own designs and drawings.
Q4: Where is your factory located?
A4: Our factory is situated in the East Lake Industrial Park of
XinTang Town, Zengcheng District, Guangzhou City, Guangdong
Province, China.
Q5: How can I get to your factory?
A5: Due to convenient transportation, you can reach us by taxi or
by subway. If taking the subway, please take Line 13 to Shacun
Station. Before disembarking, kindly inform us in advance, and we
will arrange for a comfortable business van to pick you up from
there.