Model Number QMQ5.6/150W-XL-009
Certification UL,FM,CMA,CNAS,CAL
Place of Origin China
Minimum Order Quantity 1
Price US$950-US$1,000
Payment Terms L/C,D/P,T/T,Western Union,Paypal,Credit Card
Supply Ability 20000 Sets Per Week
Delivery Time 10 Days, Subject To Quantity Negotiation
Packaging Details Plywood Outer Box With Bubble Bag Or Paper
Fire Suppression Agent: HFC 227ea
Filling Density ≤1250kg/m³
Operating Temperature Range 0℃~50℃
Storage Pressure 0.3MPa ( +20℃)
Maximum Operating Pressure 8MPa (+50℃)
ire Extinguishing Method Total Flooding Fire Suppression
Feature Environmental Friendly Gas
Application Scenario Data Centers
System Type Inert Gas Fire Suppression System
System Discharge Time ≤8 Seconds For Computer Rooms, ≤10 Seconds For Others
Fire Extinguishing Design Concentration 8~10%
System Activation Methods Automatic, Manual, Mechanical Emergency Start
Detailed Product Description

Hfc227ea Clean Gas Automatic Fire Extinguishing System For Data Center

Product Description:

HFC-227ea Automatic Fire Extinguishing System is a next-generation fire suppression solution engineered specifically for high-value, mission-critical environments where traditional fire-fighting methods like water sprinklers can cause catastrophic secondary damage. At its core, this system utilizes HFC-227ea (also known as FM-200), a colorless, odorless, and electrically non-conductive clean agent that extinguishes fires through a dual mechanism: rapid heat absorption and chemical interruption of the combustion chain reaction. Unlike inert gases that reduce oxygen levels, the HFC-227ea Automatic Fire Extinguishing System suppresses flames while maintaining breathable atmospheric conditions, making it safe for use in occupied spaces such as data center operation rooms and network control centers.

One of the defining features of the HFC-227ea Automatic Fire Extinguishing System is its ultra-fast response time—typically discharging the required agent concentration within 10 seconds of fire detection. This speed is crucial in data centers, where even a minor fire can escalate rapidly due to high-density electrical loads and continuous equipment operation. Because HFC-227ea leaves no residue, there is no need for post-discharge cleanup, minimizing equipment downtime and eliminating corrosion risks to servers, switches, and storage arrays.

Unlike traditional water-based systems, the Hfc227ea Automatic Fire Extinguishing System eliminates risks of electrical short-circuiting or corrosion, making it ideal for live environments. Its non-conductive properties and compatibility with UPS systems, backup generators, and HVAC infrastructure further enhance safety. The system complies with global standards including ISO 14520, NFPA 2001, and UL/FM certifications, with an ozone depletion potential (ODP) of zero and a global warming potential (GWP) of 3,220—significantly lower than legacy agents like Halon 1301.

 

 

Technical Parameters:

Execution StandardQ/GZXL001-2021
Model NumberQMQ5.6/150W-XL-009
Cylinder Capacity150L
FeatureClean Gas And Environmental Friendly
Filling Density≤1250kg/m³
Operating Temperature Range0℃~50℃
Storage Pressure0.3MPa ( +20℃)
Maximum Operating Pressure8MPa (+50℃)
System Discharge Time≤8 Seconds For Computer Rooms, ≤10 Seconds For Others
Fire Extinguishing Design Concentration8~10%
Fire Suppression AgentHFC 227ea
Fire Extinguishing MethodTotal Flooding Fire Suppression
System Activation MethodsAutomatic, Manual, Mechanical Emergency Start
Application ScenarioData Centers
HighlightInert Gas Fire Suppression System
 

Applications:

Data centers are high-stakes environments where even minutes of downtime can result in millions of dollars in losses and irreparable reputational damage. The Hfc227ea Automatic Fire Extinguishing System addresses these risks through tailored features designed for 24/7 operational continuity. In a fire event, the system’s ultra-fast response time (≤10 seconds) minimizes heat buildup, preventing thermal runaway in server racks and lithium-ion battery arrays. This is critical for modern data centers housing high-density compute clusters and edge computing nodes.

The agent’s residue-free discharge ensures no post-fire cleanup, allowing immediate resumption of operations. For example, in a hypothetical scenario involving a short circuit in a power distribution unit (PDU), the system would suppress the fire before it spreads to adjacent racks, avoiding cascading failures. Additionally, the Hfc227ea Automatic Fire Extinguishing System’s low-pressure storage (4.2MPa) reduces installation complexity and maintenance costs compared to high-pressure alternatives.

 

 

 

Company profile:

Guangzhou Xinlin Firefighting Equipment Co., Ltd. is located in Guangzhou, a vital city connecting China to the world, characterized by its convenient transportation and picturesque environment. We are a manufacturing company with a professional and seasoned team of employees, consisting of solution design experts, technical installation specialists, quality inspection professionals, and after-sales service teams, dedicated to the research and development of HFC-227ea (FM200), IG541, IG100, and Novec 1230 products.
Currently, we offer a range of commonly used fire suppression systems, including FM200 fire suppression systems, cabinet-style FM200 fire suppression systems, fully automatic FM200 extinguishers (ceiling-mounted), IG541 fire suppression systems, IG100 fire suppression systems, fire detection tube fire suppression systems, as well as automatic fire extinguishing pipelines. 

 

Frequently Asked Questions:

Q1: Are you a manufacturer or a trading company?
A1: We are a professional manufacturer specializing in gas fire suppression systems.
 
Q2: Do you offer OEM products?
A2: Yes, we welcome your own designs and drawings.
 
Q3: Where is your factory located?
A3: Our factory is situated in the East Lake Industrial Park of XinTang Town, Zengcheng District, Guangzhou City, Guangdong Province, China.
 
Q4: How can I get to your factory?
A4: Due to convenient transportation, you can reach us by taxi or by subway. If taking the subway, please take Line 13 to Shacun Station. Before disembarking, kindly inform us in advance, and we will arrange for a comfortable business van to pick you up from there.
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: Guangzhou Xinlin Fire Fighting Equipment Co., Ltd.
Subject:
Message:
Characters Remaining: (80/3000)