TUV Certification IG100 Clean Agent Fire Suppression System
Integrates Seamlessly With Alarm Systems
Technical parameter:
No. | Product | IG100 Nitrogen Fire Fighting System |
1 | Capacity | 70ltr,80ltr,90ltr |
2 | Working Pressure | 20MPa | 30MPa |
3 | Device Model | QMH20/90 | QMH30/90 |
4 | Model Number | QMD20/70-XL |
5 | Discharge Time | ≤60S |
6 | Working pressure and temperature | 0~50℃ |
7 | Driving Bottle Group Pressure | 23.5MPa |
8 | Maximum Working Pressure at 50℃ | 237.5kg/M³ |
9 | Fire Extinguishing Method | Full Flooding |
10 | Activation Method | Automatic, Pneumatic, Manual, Mechanical Emergency Operation |
11 | Applications | Medical facilities |
Description:
IG100 Clean Agent Fire Suppression System leverages the inert
properties of nitrogen (N₂) to deliver advanced fire protection for
server rooms. As a pure gaseous clean agent, nitrogen offers
distinct advantages over traditional suppressants:
Non-Conductive Purity: With 99.97% nitrogen concentration, the
system ensures zero electrical conductivity, making it ideal for
safeguarding sensitive IT infrastructure like servers, routers, and
storage arrays. Unlike water or dry powder, the nitrogen agent does
not induce short circuits or damage electronic components during or
after fire suppression.
Environmentally Benign: Nitrogen is a natural component of Earth’s
atmosphere (comprising 78% of air), ensuring zero ozone depletion
potential (ODP) and zero global warming potential (GWP). This
aligns with international sustainability standards, making the
IG100 system compliant with LEED-certified green buildings and
eco-conscious data centers.
Residue-Free Operation: The gaseous agent dissipates completely
after fire suppression, leaving no particulate, chemical, or
moisture residue. This eliminates post-fire cleanup costs and
downtime, allowing server rooms to resume full operation within
minutes.
Thermal Stability: Nitrogen maintains chemical stability even at
high temperatures, preventing the release of toxic byproducts
during fire events. This ensures safe occupancy for personnel and
protects long-term equipment reliability.
Application:
IG100 Clean Agent Fire Suppression System is engineered to combat a
wide range of fire classes in server room environments:
1. Class A Fires (Common Combustibles)
While rare in server rooms, Class A fires from paper, wood, or
plastic insulation can occur due to cable overheating. The nitrogen
agent suppresses these fires by reducing oxygen concentration to
below 15%, the threshold for sustained combustion. This method is
particularly effective in preventing smoldering residues that could
reignite, unlike water-based systems that may leave damp materials
prone to secondary fires.
2. Class B Fires (Flammable Liquids/Gases)
Server rooms often house backup power systems with lithium-ion
batteries or small quantities of flammable coolants. The IG100
system rapidly suppresses Class B fires by disrupting the fire’s
chemical reaction chain, preventing vapor cloud explosions and
containing fires within battery enclosures or fluid storage areas.
Case studies show a 92% reduction in fire spread time compared to
dry chemical systems in similar scenarios.
3. Class C Fires (Energized Electrical Equipment)
As the primary fire risk in server rooms, Class C fires from short
circuits or overloaded power supplies require non-conductive
suppression. The IG100 system’s nitrogen agent safely extinguishes
these fires without risking electrical arcs or equipment damage,
unlike water which conducts electricity and exacerbates hazards.
This makes it compliant with NFPA 75 (Standard for the Fire
Protection of Information Technology Equipment).
4. Class K Fires (Cooking Oils – Ancillary Risks)
In server rooms co-located with kitchenettes or maintenance areas,
the IG100 system provides secondary protection against Class K
fires. While not its primary design, the agent’s ability to
suppress deep-seated fires in cooking oils by smothering flames
ensures comprehensive coverage for hybrid-use facilities.
5. Specialized Risks in Modern Server Rooms
Aerosolized Coolants: For server rooms using liquid-cooled systems
with dielectric fluids, the IG100 agent suppresses fires without
contaminating the coolant, preserving expensive infrastructure.
Company profile:
Guangzhou Xinlin Fire Fighting Equipment Co., Ltd., established in
2017 with a registered capital of RMB 10 million, is a leading
provider of advanced fire safety solutions headquartered in
Dongzhou Industrial Park, Xintang Town, Zengcheng District,
Guangzhou. Committed to innovation and reliability, the company
specializes in state-of-the-art clean gas automatic fire
extinguishing systems, including FM200(HFC-227ea),Novec1230,IG541
and IG100 systems, complemented by sophisticated gas fire alarm
control panels.These products are widely adopted across diverse
sectors, such as municipal infrastructure, power plants,
telecommunications, healthcare facilities, and construction
projects, thanks to their efficiency, safety, and environmental
sustainability.
Supported by over 30 patents and a team with more than eight years
of collective expertise in fire protection engineering, Xinlin Fire
offers comprehensive services spanning system design, engineering,
and seamless project execution. Operating from a modern 2398 -
square - meter facility, Xinlin Fire integrates automated
production lines and cutting - edge testing equipment to ensure
consistent, high - quality output.
The company's production system has passed the dual certifications
of the internationally authoritative SGS factory inspection
certification and the German TÜV Rheinland factory inspection. At the same time, it has obtained ISO
9001 (Quality Management System), ISO 14001 (Environmental
Management System), and ISO 45001 (Occupational Health and Safety
Management System). Ensure that every link of the product from
production to delivery complies with international standards. In
addition, we also provide Chemical Data Sheets (MSDS) to
comprehensively ensure the compliance and safety of product
transportation, storage and use. Choosing us means choosing
professionalism and trust.
Frequently Asked Questions:
Q1: Are you a manufacturer or a trading company?
A1: We are a professional manufacturer specializing in gas fire
suppression systems.
Q2: Can you give me a sample order?
A2: Yes, of course you can. We welcome you to order samples to test
and check the product quality. Provide mixed samples.
Q3: Do you offer OEM products?
A3: Yes, we welcome your own designs and drawings.
Q4: Where is your factory located?
A4: Our factory is situated in the East Lake Industrial Park of
XinTang Town, Zengcheng District, Guangzhou City, Guangdong
Province, China.
Q5: How can I get to your factory?
A5: Due to convenient transportation, you can reach us by taxi or
by subway. If taking the subway, please take Line 13 to Shacun
Station. Before disembarking, kindly inform us in advance, and we
will arrange for a comfortable business van to pick you up from
there.