China SF6 Recovery System manufacturer
Shanghai Kstone S&T Development Co .,LTD.
1
Home > Products > C4F7N Series Instruments And Equipment >

C4F7N Mixing Ratio Tester C4F7N CO2 O2 Moisture Content

Browse Categories

Shanghai Kstone S&T Development Co .,LTD.

City: shanghai

Province/State:shanghai

Country/Region:china

Tel:86-21-50912468

Contact Person:
Ms.Jin
View Contact Details

C4F7N Mixing Ratio Tester C4F7N CO2 O2 Moisture Content

Brand Name kstone
Model Number KS30-C4-4
Certification iso9001
Place of Origin SHANGHAI
Minimum Order Quantity 1
Price $15000-16000
Payment Terms T/T
Supply Ability 100
Delivery Time 30 workdays
Packaging Details Fumigation wooden box
Application Industrial and Scientific
Power Supply AC/DC
Storage Temperature -20-70°C
Dimensions Varies depending on specific instrument
Weight Varies depending on specific instrument
Operating Temperature 0-50°C
Interface USB/Ethernet
Measurement Range Varies depending on specific instrument
Detailed Product Description

C4F7N Mixing Ratio Tester, C4F7N,CO2,O2, Moisture Content


KS31-C4-4 C4 Mixing Ratio Tester (C4F7N:CO2:O2:dewpoint)


C4F7N abbreviated as C4


The C4 comprehensive tester is a specialized testing tool that integrates C4humidity,C4 concentration, CO2, and O2.
The excellent performance of the C4 gas comprehensive tester is due to the use of the best foreign sensors; Humidity is measured using Finnish Vaisala, C4 and CO2 are measured using infrared sensors, and O2 is measured using electrochemical sensors;
When needed, decomposition products can be stacked and combined to form a C4 mixed gas comprehensive tester, with imported sensors used for decomposition products.
The instrument adopts a color LCD display, which displays various parameters in real time, with a foolproof operation throughout the process, massive information storage, built-in rechargeable battery, and dual-use of AC and DC.


1. Technical Parameter Response Table

ParameterDetails
Gas Flow Rate- Humidity measurement: 0.5–0.6 L/min
- Purity measurement: 0.2–0.3 L/min
- Electronic mass flowmeter: Sample gas flow rate has no effect
Pressure Measurement0–1.0 MPa
Probe ProtectionStainless steel sintered filter screen
C4 Humidity- Measurement range: Dew point -80~+20 °C (supports ppmv, etc.)
- Dew point accuracy: ±1 °C (when dew point <0 °C, sensor outputs frost point)
- Response time (63% [90%]):
• +20→-20°C Td: 5s [45s]
• -20→-60°C Td: 10s [240s]
- Resolution: 0.1 °C or 0.1 ppm
- Repeatability: ±1 °C
C4 Ratio- Range: 0–12% C4 (based on common industry usage)
- Accuracy & repeatability: ±0.5%
O2 Ratio- Measurement range: 0–25%
- Accuracy: ±0.5%
CO2 Ratio- Measurement range: 0–100%
- Accuracy: ±0.5%


General Part:

Working Voltage85–264VAC 50Hz, AC/DC dual-use, with overcharge protection
Continuous Operation≥10 hours
Storage Temperature-40~+70 °C
Output InterfaceUSB 1.1 specification
Data StorageStores 200 records
Operating Environment- Temperature: -30~+60 °C
- Pressure: 0–20 bar
PrinterBuilt-in thermal printer for fast, silent data printing
USB FunctionalityConnects to host computer for data transfer, storage, and processing
Dimensions (L×W×H)335 × 290 × 160 mm
Weight5.7 kg



2. List of Goods Demand and Supply Scope

Serial NumberInstrument NameUnitQuantity
1C4 Comprehensive Tester Platform KS30-C4-4Set1
2Intake Pipe Sleeve5m Roll1
3Exhaust PipePiece1
4Power Cord (3×0.75)Piece1
5Printing Paper RollRoll1
6Portable Aluminum Alloy Outer BoxPiece1


3. Random file

NumberNameQuantity
1English Instruction Manual1
2English Product Factory Inspection Report1
3English Product Qualification Certificate1
4English Packing List1



About C4 

3m-novec-4710-insulating-gas

Introduction

3M™ Novec™ 4710 Insulating Gas is a sustainable alternative to sulfur hexafluoride (SF6) for electrical equipment

insulation and arc quenching applications. It offers excellent dielectric properties, a wide range of operating

temperatures and significant reductions in environmental impacts compared to SF6. Novec 4710 gas is non-

flammable and has a wide safety margin for workers when used as designed for intended applications. This

SF6 alternative also has important environmental properties such as low global warming potential (GWP) when

mixed with inert gases and zero ozone depletion potential (ODP). Novec 4710 gas in pure form has a relative

dielectric strength two times greater than SF6 at a given pressure.


The current manufacturing enterprises in China include: Yuji, Hexafluo, and Haohua; yuji;

On December 20, 2022, 3M announced that it will cease production of 58 Per/polyfluoroalkyl substances (PFAS) products, including perfluoroisobutyronitrile (C4F7N, 3M Novec 4710) and perfluoropentanone (C5F10O, 3M Novec 5110), by the end of 2025 to reduce or eliminate the impact of PFAS on climate, environment, and ecological health.


Application scenarios of C4 gas in ultra-high voltage electrical systems:
In recent years, numerous ultra-high voltage enterprises in China have been conducting research, testing, and experimentation on the application of C4 for many years, mainly including as China Xidian, Changgao, Ankura, and Shenma.International brands include GE and Siemens Energy;


KSTONE  is a leading enterprise in China that develops C4 and C5 related instruments and equipment;and has precise cooperation with 3M and  chinese C4 or C5 manufacturers ;


For more requirements, please contact info@kstone-sf6.com








Product Tags: CO2 C4F7N Mixing Ratio Tester   O2 C4F7N Mixing Ratio Tester  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: Shanghai Kstone S&T Development Co .,LTD.
Subject:
Message:
Characters Remaining: (80/3000)