NT BUILD 492 Concrete Chloride Ion Diffusion Coefficient Tester The NT BUILD 492 Concrete Chloride Ion Diffusion Coefficient Tester
quantitatively evaluates concrete's resistance capacity to chloride
ion diffusion. Based on DuraCrete unsteady electromigration test
theory, this equipment provides essential parameters for designing
and assessing the durability of concrete structures in chloride ion
erosion environments. This tester is suitable for concrete specimens with maximum
aggregate size not exceeding 25mm (typically not more than 20mm),
whether laboratory-produced or core samples. The resulting data
serves as a foundation for concrete durability mix design in
chloride environments and for quality inspection and assessment. Compliance Standards - NT BUILD 492 Chloride Migration Coefficient from Non-Steady-State
Migration Experiments
- EU Project CHLORTEST G6RD-CT-2002-00855
- CEN TC 51 (CEN TC 104)/WG12/TG5
- Guide to Durability Design and Construction of Concrete Structures
- CCES-01-2004 Standard for test methods of long-term performance and
durability of concrete
Technical Specifications | Test Channels | 6, 9, or 12 channels selectable | | Temperature Data | ±0.2℃ | | Output Voltage | DC 0-60V adjustable (±0.1V), 12-bit adaptive voltage regulation
technology | | Input Power Supply Voltage | AC220V±10/50Hz | | Core | 32-bit embedded ARM core | | LCD Display | 7-inch industrial touch screen | | Voltage Regulation Mode | Adaptive voltage regulation mode |
Key Features - 0-60V adjustable voltage with short circuit auto-protection and
automatic control of the entire electric migration process
- Embedded computer control with power outage data storage, advanced
technology, and reliable high-accuracy performance
- LCD display with real-time display/print and analysis functions;
can operate independently from PC
- Standard RS232 serial communications with fully automatic PC
connection software for data monitoring
- Built-in analysis and calculation functions; automatically computes
test results after parameter input
- Automatic short circuit protection to prevent equipment damage
- High-precision imported material fixtures for easy and smart
operation
- Simultaneous testing capability for multiple concrete blocks (6, 9,
or 12 at once)
- Includes latest smart-in-one vacuum saturation machine
Experimental Procedure - Cut concrete sample into cylindrical test blocks (100mm diameter,
50±2mm thickness)
- Clean test blocks using ultrasonic cleaning
- Install cleaned sample on specimen fixture, inject test solution,
and connect to test host
- Activate SY-RCM chloride migration coefficient tester for
electromigration experiments
- After electromigration, split sample axially and spray silver
nitrate on the split surface
- Input data into host for automatic calculation of channel migration
coefficient
|