Flammability Testing Equipment IEC60695 0.1Mpa Horizontal And
Vertical Combustion Equipment , Product Introduction Among the key indicators of product safety performance, fire
resistance is of vital importance. As a source manufacturer, the
HVF-3 horizontal vertical combustion device is a professional
instrument carefully built by us to meet the market demand for
accurate fire testing equipment. It combines advanced technology
with reliable performance and plays a key role in the field of
product fire testing. Whether it is plastics, electronics, or
construction and automotive interior industries, it can be used to
accurately evaluate the combustion characteristics of products and
build a solid line of defense for product safety. Product Features The burning angle can be adjusted between 0°, 20°, and 45° as
needed, which can accurately simulate the fire state of the product
in different fire scenarios and meet diverse testing needs. It has two test flame powers of 50W and 500W, which can be flexibly
switched according to different product materials and test
standards to ensure the pertinence and accuracy of the test. The gas pressure is stable at 0.1MPa, and the gas flow is finely
adjusted by the flow meter. The U-type pressure gauge accurately
controls the height of the back pressure water column to achieve
highly accurate test conditions. Intelligent control experience: PLC control is adopted, with a
7-inch color touch screen, and the operation is intuitive and
convenient. It also supports infrared remote control, which can
remotely preset parameters such as burning time and number of
burning times, greatly improving test efficiency. The burner is made of high-quality brass and is manufactured in
strict accordance with IEC60695 and other standards to ensure the
standardization of the test. The test chamber is made of 304
stainless steel, with a size greater than 0.75 cubic meters, and is
fully equipped with internal lighting, exhaust fans, etc. to ensure
stable operation of the equipment and safe test environment. Equipped with high-precision thermocouples to accurately measure
temperature, the test flame is calibrated in strict accordance with
regulations, and reliable temperature data support is provided for
combustion testing.Technical Parameters Parameters | Details | Working Voltage | 220V/50Hz | Power/Grade | HVF - 1: 50W or 500W; HVF - 2, HVF - 3 (Touch Screen): Dual power
switching of 50W and 500W | Control Operation Mode | HVF - 1, HVF - 2: Electric control, button operation; HVF - 3
(Touch Screen): PLC control, 7-inch color touch screen operation,
with infrared remote control | Burner Standard | Complies with IEC60695 - 11 - 3/IEC60695 - 11 - 4/10, UL94
standards, with an inner diameter of Φ9.5±0.3mm, a length of 100mm,
and made of brass | Gas Pressure | 0.1MPa | Gas Flow | 50W: 105±5ml/min or 18±1mm; 500W: 965±30ml/min or 117±3mm,
adjustable by a flow meter | U-shaped Pressure Gauge Back Pressure Water Column Height | 50W: 10mm; 500W: 125±5mm | Test Angle | 50W: 0°, 45°; 500W: 20° | Burning Time | 0 - 9999×0.1S can be preset | Burning Times | 0 - 9999 times can be preset | Afterflame/Afterglow Time | 0 - 9999×0.1S can be displayed | Test Flame Calibration | 50W: Temperature measuring copper head is Ф5.5mm±0.01mm, with a
weight of 1.76±0.01g before drilling; 500W: Ф9mm±0.01mm, with a
weight of 10±0.05g before drilling; Thermocouple is the American
original Omega φ0.5 armored nickel-chromium/nickel-aluminum wire
K-thermocouple with a temperature resistance of 1100°; Distance
from the Bunsen burner port to the temperature measuring copper
block is 10±1mm at 50W and 55±1mm at 500W; Flame height is 20±2mm
(no inner and outer flame) at 50W, 40±2mm for the inner flame and
125±10mm for the outer flame at 500W; Temperature rise time from
100±2° to 700°±3° is 44±2S at 50W and 54±2S at 500W | Lighting | Equipped with lighting in the test chamber with control | Test Chamber and Dimensions | >0.75 cubic meters, with a black inner wall, an exhaust fan, and
dimensions of 11005501200mm and a weight of 140kg |
| |
International Reference Standards • IEC 60695: Flammability test standard specified by the
International Electrotechnical Commission. • UL 94: Flammability standard for plastic materials of the
Underwriters Laboratories of the United States. • GB/T 2408: Flammability performance standard for plastics of the
Chinese national standard. This is a flame tester that complies with IEC60695, with a working
voltage of 220V/50Hz and power options of 50W and 500W. It adheres
to multiple standards like UL94 and IEC60695 series. It's used to
assess ignition hazard by simulating fire's initial flame impact on
products, mainly for non-metallic materials and foam plastics.
Specific samples must be tested, and results determine further
evaluation. The tester features an integrated ignition system,
delay for full combustion, and has various components for accurate
testing and a good appearance, combining many domestic and foreign
product advantages.
|