Mechanical Knob Ultrasonic Cleaner Ultrasonic Surgical
Instrument Cleaning Bath
Specification:
Ultrasonic Frequency | 40KHz |
Material | Stainless Steel SUS304 |
Tank Capacity | 30L |
Timer | 1-30minutes , Mechanical timer |
Heater | 20°C to 80°C, Mechanical Heating |
Power Supply | AC 100 ~ 120V, 50 / 60Hz |
AC 220 ~ 240V, 50 / 60 Hz |
Ultrasonic Power | 600 W |
Heating Power | 500 W |
Tank Size | 500 x 300 x 200 mm ( L x W x H ) |
Unit Size | 530 x 325 x 325 mm ( L x W x H ) |
Package Size | 635 x 405 x 390 mm ( L x W x H ) |
N.W. | 15.0kg |
G.W. | 16.0kg |
Control panel:
Details:
Extra-Thick Tank and Silica Gel to Reduce Noise
Extra-thick 0.4inches(1.0mm) Stainless Steel 304 inner tank with
silver ion oxidation cover and smooth coasted layer, it is
corrosion and good stability.
Sound insulation silica gel material is soft that has the function
of shock absorption, we stick it all round the inner tank, it can
effectively reduce the spread of noise of ultrasonic vibration,
thereby protecting hearing from harmful noise.
Convenient Handle and SUS304 Drain Value
Plastic handle at both side for easy machine movement. more
convenient and protect hands hurt.
SUS304 stainless steel basket is to decrease collision between
sharp items and tank, which ensures it for long-term use; Also can
be used to drip dry items, experience more comfortable
500W Heating Power for removing oil and wax
High heating power can heat water faster than others. Heating can
decrease the adhesive strength of oil and wax to certain stuffs to
be cleaned, make the cleaning solution much easiler to create
cavitations under ultrasonic wave and strengthen cavitation so as
to increase the cavitation level of cleaning solution, and then
enhance the cleaning effect
Suggested Ultrasonic Cleaning Procedure
In all cases manufacturers’ instructions should be followed when
using an ultrasonic cleaning process. These are representative
steps.
Fill the ultrasonic cleaning tank with an approved medical
instrument cleaning solution such as CLN-LR012 available from
Tovatech following dilution instructions provided. Turn the cleaner
on to start the degassing process. This step removes entrained air
in new solutions that interferes with the efficiency of cavitation
and takes approximately 10 minutes.
In the meantime:
- Segregate instruments by alloy or composition to avoid potential
damage (Chromium plated instruments should not be cleaned
ultrasonically)
- Instruments with movable parts should be disassembled to facilitate
cleaning
- Place the instruments the ultrasonic cleaner’s mesh basket, taking
care that they do not come in contact with each other
- Cannulated or lumened instruments should be positioned to insure
interiors are wetted with the cleaning solution. In some instances
placing them on an angle will facilitate this
- Set the control panel per manufacturers’ instructions and start the
cleaning process
At the end of the cycle, remove the instruments from the ultrasonic
cleaning bath and thoroughly rinse them to remove all traces of the
cleaning solution. Deionized water rinses will avoid spotting. If
the instruments are not to be immediately disinfected and
sterilized be certain that they are thoroughly dried and protected.
Part reassembly can occur after sterilization.
Procedures should be in place to guide the replacement of used
ultrasonic cleaning solutions. In some instances it is recommended
that solution be drained and tanks thoroughly cleaned and dried
after each ultrasonic cleaning cycle. Most solutions available
today are biodegradable, which facilitates disposal but local
authorities should be consulted on proper practices.
The ultrasonic cleaner uses ultrasonic waves (vibration) using
water with detergents or enzymatic products to break up soil and
organic material on medical instruments/devices. These devices are
rinsed then autoclaved (sterilized). The autoclave sterilizer uses
heat, steam, and pressure to kill all pathogenic microorganisms and
their spores.
Package Includes:
1 x Digital Ultrasonic Cleaner
1 x Cleaning Basket
1 x Manual
Size: